ASTM D5996-05
Historical Standard: ASTM D5996-05 Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography
SUPERSEDED (see Active link, below)
ASTM D5996
1. Scope
1.1 This test method covers on-line analysis of high-purity water by the ion chromatography technique. This test method is applicable for measuring various anionic contaminants in high-purity water, typically in the range of 0.01 to 100 g/L. This test method is used to determine the concentration of acetate, formate, chloride, fluoride, phosphate, nitrate, and sulfate in a continuously flowing sample. The range of the test method is only as good as the reagent water available for preparing standards. At extremely low concentrations, 1.0 g/L, preparing standards is difficult, and extra care must be taken in their preparation. The sample may have to be conditioned from higher pressures and temperatures to conditions that are suitable for use by on-line instruments.
1.2 Online sample analysis of flowing streams does not lend itself to collaborative studies due to the nature of the sample and the possibility of contamination that may result from handling the sample as part of the collaborative study. Therefore this standard test method is not based on the results of a collaborative study but is intended to provide the best possible guidance for doing this type of analysis.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1066 Practice for Sampling Steam
D1129 Terminology Relating to Water
D1192 Guide for Equipment for Sampling Water and Steam in Closed Conduits
D1193 Specification for Reagent Water
D2777 Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
D3370 Practices for Sampling Water from Closed Conduits
D3864 Guide for Continual On-Line Monitoring Systems for Water Analysis
D4453 Practice for Handling of High Purity Water Samples
D5542 Test Methods for Trace Anions in High Purity Water by Ion Chromatography
D5810 Guide for Spiking into Aqueous Samples
D5847 Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis
Keywords
anions; high purity; ion chromatography; on-line; Acetate concentration; Anionic contamination; Chloride analysis--water applications; Contamination--water; Fluoride (ion) analysis; Formate; High-purity water; Ion chromatography (IC); Nitrate (ion) analysis; Online monitoring (in water analysis); Phosphate content--water applications; Sulfate content--water;
ICS Code
ICS Number Code 71.040.50 (Physicochemical methods of analysis)
DOI: 10.1520/D5996-05