Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(2114)
(64)
(92448)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    24/30443602 DC EN 1993-4-2 Eurocode 3. Design of steel structures. - Part 4-2: Tanks
    Edition: 2024
    $42.22
    / user per year

Description of 24/30443602 DC 2024

1.1 Scope of EN 1993-4-2 (1) EN 1993-4-2 provides rules for structural design of vertical cylindrical, conical and pedestal above-ground steel tanks for the storage of liquid and liquified gas products. (2) EN 1993-4-2 is applicable to the design for resistance of cylindrical walls and flat bottoms constructed using unstiffened plates. The design of conical and dome roofs as shell structures (unsupported) or as supported on a structural framework (supported) are also covered. (3) EN 1993-4-2 is only applicable to the requirements for resistance and structural stability of steel tanks. (4) EN 1993-4-2 only covers steel tank structures in Tank Groups 1, 2 and 3, as defined in this document. NOTE Tank Group 4 is not defined in this standard (see 3.1.41). (5) This document is applicable to tanks within the following dimensional limits (see EN 1991-4): Tank aspect ratio hS/d < 10 Tank total height hS < 70 m Tank diameter d < 100 m (6) This standard includes suitable rules for the design of tanks intended to store solids suspended in a liquid, where the appropriate global density of the mixture is used. NOTE Tanks used for the separation of mineral particles of different density fall into this category. (7) EN 1993-4-2 does not apply to the following: a) tanks with gross capacity less than 5 m3 (5 000 l); b) dished-end tanks that have a diameter less than 5 m; c) tanks with characteristic internal pressures above the liquid surface greater than 50 kPa (500 mbar) (see pressure equipment directive); d) design metal temperatures outside the ranges defined in Clause 5, with −50 °C being the lowest temperature for the application of this document; e) tanks of rectangular and other non-circular planforms; f) tanks exposed to fire; g) floating roofs and floating covers; h) ancillary structures such as stairways, platforms, nozzles, piping and access doors. (8) This document does not cover a) the special requirements for seismic design of tanks, b) the design of a supporting structure, c) the design of ancillary structures such as stairways, platforms, pipe racks and ladders, d) the design of an aluminium roof structure on a steel tank, e) reinforced concrete foundations for steel tanks, f) the design of a conical hopper, g) the design of a transition junction between the base of a cylindrical shell wall and a conical hopper, h) the design of a supporting ring girder in an elevated tank. 1.2 Assumptions (1) Unless specifically stated, EN 1990, the EN 1991 series and the EN 1993-1 series apply. (2) The design methods given in this document apply if: - the execution quality is as specified in EN 1090-2, and - the construction materials and products used are as specified in the relevant parts of the EN 1993 series, or in the relevant material and product specifications. (3) This standard applies to axisymmetric structures, but includes the effects of unsymmetrical actions (e.g. wind), and unsymmetrically supported tanks (e.g. on discrete supports). (4) EN 1993-4-2 is intended to be used in conjunction with EN 1990, with EN 1991-4, with the other Parts of EN 1991, with EN 1993-1-6 and EN 1993-4-1, with the other Parts of EN 1993, with EN 1992 and with the other Parts of EN 1994 to EN 1999 relevant to the design of tanks. Matters that are already covered in those documents are not repeated. (5) Numerical values for partial factors and other reliability parameters are recommended as basic values that provide an acceptable level of reliability. They have been selected assuming that an appropriate level of workmanship and quality management applies.

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X