Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(44)
(234)
(969)
(643)
(2114)
(64)
(92448)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS EN 62271-104:2015 High-voltage switchgear and controlgear - Alternating current switches for rated voltages higher than 52 kV
    Edition: 2015
    $497.46
    / user per year

Description of BS EN 62271-104:2015 2015

1.1 Scope

Subclause 1.1 of IEC 62271‑1:2007 is not applicable, and is replaced as follows:

This part of IEC 62271 is applicable to three-pole alternating current switches for rated voltages higher than 52 kV, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz.

This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.

NOTE 1

Switches for gas insulated switchgear are covered by this standard.

NOTE 2

Switches having a disconnecting function and called switch-disconnectors are also covered by IEC 62271‑102 .

NOTE 3

Earthing switches are not covered by this standard. Earthing switches forming an integral part of a switch are covered by IEC 62271‑102 .

The main object of this standard is to establish requirements for switches used in transmission and distribution systems. General-purpose switches for this application are designed to comply with the following service applications:

  • arrying rated normal current continuously;

  • carrying short-circuit currents for a specified time;

  • switching of mainly active loads;

  • switching of no-load transformers;

  • switching of the charging current of unloaded cables, overhead lines or busbars;

  • switching of closed-loop circuits;

  • making short-circuit currents.

A further object of this standard is to establish requirements for limited-purpose and special-purpose switches used in transmission and distribution systems.

Limited-purpose switches comply with one or more of the service applications indicated above.

Special-purpose switches may comply with one or more of the service applications indicated above and, in addition, are suitable for one or more of the following applications:

  • switching single capacitor banks;

  • switching back-to-back capacitor banks;

  • switching shunt reactors including secondary or tertiary reactors switched from the primary side of the transformer;

  • applications requiring an increased number of operating cycles;

  • switching under earth fault conditions in non-effectively earthed neutral systems.

1.2 Normative references

The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

  • IEC 60050‑441:1984, International Electrotechnical Vocabulary — Chapter 441: Switchgear, controlgear and fuses
  • IEC 60071 (all parts), Insulation co-ordination
  • IEC 60071‑1, Insulation co-ordination — Part 1: Definitions, principles and rules
  • IEC 60270, High-voltage test techniques — Partial discharge measurements
  • IEC 62271‑1:2007, High-voltage switchgear and controlgear — Part 1: Common specifications
    IEC 62271-1:2007/AMD1:2011
  • IEC 62271‑100:2008, High-voltage switchgear and controlgear — Part 100: Alternating-current circuit-breakers
    IEC 62271-100:2008/AMD1:2012
  • IEC 62271‑102:2001, High-voltage switchgear and controlgear — Part 102: Alternating current disconnectors and earthing switches
    IEC 62271-102:2001/AMD1:2011
    IEC 62271-102:2001/AMD2:2013
  • IEC 62271‑110:2012, High-voltage switchgear and controlgear — Part 110: Inductive load switching