Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(21)
(20)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1635)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    PD IEC/TS 61496-4-3:2015 Safety of machinery. Electro-sensitive protective equipment - Particular requirements for equipment using vision based protective devices (VBPD). Additional requirements when using stereo vision techniques (VBPDST)
    Edition: 2015
    $497.46
    / user per year

Description of PD IEC/TS 61496-4-3:2015 2015

Replacement:

This part of IEC 61496 specifies requirements for the design, construction and testing of electro-sensitive protective equipment (ESPE) designed specifically to detect persons or parts of persons as part of a safety-related system, employing vision-based protective devices (VBPDs) using stereo vision techniques (VBPDST) for the sensing function. Special attention is directed to features which ensure that an appropriate safety-related performance is achieved. An ESPE may include optional safety-related functions, the requirements for which are given in Annex A of IEC 61496‑1:2012 and this Technical Specification.

This part of IEC 61496 does not specify the dimensions or configurations of the detection zone and its disposition in relation to hazardous parts for any particular application, nor what constitutes a hazardous state of any machine. It is restricted to the functioning of the ESPE and how it interfaces with the machine.

The detection principle is based on the evaluation of images from different viewing points (stereoscopic view) for the determination of distance information. This distance information is used to determine the location of an object(s).

  • This part of IEC 61496 is limited to vision based ESPEs with distances (stereo base) and directions between the different imaging devices fixed during manufacture.

  • It is limited to vision based ESPEs, with a minimum distance from the sensing device to the detection zone of 4 times of the stereo base.

  • It is limited to vision based ESPEs that can detect objects with at least 5 pixel diameter in the image plane.

  • It is limited to vision based ESPEs that do not require human intervention for detection.

  • It is limited to vision based ESPEs that detect objects entering into or being present in a detection zone(s).

  • It is limited to VBPDSTs employing radiation at wavelengths within the range 400 nm to 1 500 nm.

  • This part of IEC 61496 does not address those aspects required for complex classification or differentiation of the object detected.

  • This part of IEC 61496 does not consider the aspects of a moving ESPE installation.

Additional requirements and tests can apply in the following cases:

  • Use of multi-spectral (colour) techniques;

  • Setups other than as shown in Figures of 4.1.2 (e.g. changing backgrounds, horizontal orientation of the optical axis with respect to the floor);

  • Intended for outdoor applications.

This technical specification is relevant for VBPDSTs having a stated detection capability up to 200 mm.

This technical specification may be relevant to applications other than those for the protection of persons or parts of persons like arm or fingers (in the range 14 mm to 200 mm), for example the protection of machinery or products from mechanical damage. In those applications, additional requirements can be necessary, for example when the materials that are to be recognized by the sensing function have different properties from those of persons.

This technical specification does not deal with EMC emission requirements.



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X