Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
IEEE Standard for Ethernet - Amendment 11: Physical Layers and Management Parameters for 100 Gb/s and 400 Gb/s Operation over Single-Mode Fiber at 100 Gb/s per Wavelength, 2021
- IEEE Std 802.3cu-2021 Front Cover
- Title page
- Important Notices and Disclaimers Concerning IEEE Standards Documents
- Participants
- Introduction
- Contents
- 1. Introduction [Go to Page]
- 1.4 Definitions
- 30. Management [Go to Page]
- 30.5 Layer management for medium attachment units (MAUs) [Go to Page]
- 30.5.1 MAU managed object class [Go to Page]
- 30.5.1.1 MAU attributes [Go to Page]
- 30.5.1.1.2 aMAUType
- 45. Management Data Input/Output (MDIO) Interface [Go to Page]
- 45.2 MDIO Interface Registers [Go to Page]
- 45.2.1 PMA/PMD registers [Go to Page]
- 45.2.1.6 PMA/PMD control 2 register (Register 1.7)
- 45.2.1.7 PMA/PMD status 2 register (Register 1.8) [Go to Page]
- 45.2.1.7.4 Transmit fault (1.8.11)
- 45.2.1.7.5 Receive fault (1.8.10)
- 45.2.1.8 PMD transmit disable register (Register 1.9)
- 45.2.1.21 400G PMA/PMD extended ability register (Register 1.24) [Go to Page]
- 45.2.1.21.1a1 400GBASE-LR4-6 ability (1.24.9)
- 45.2.1.21.1a2 400GBASE-FR4 ability (1.24.8)
- 45.2.1.21b 40G/100G PMA/PMD extended ability 2 (Register 1.26) [Go to Page]
- 45.2.1.21b.3a 100GBASE-LR1 ability (1.26.5)
- 45.2.1.21b.3b 100GBASE-FR1 ability (1.26.4)
- 78. Energy-Efficient Ethernet (EEE) [Go to Page]
- 78.1 Overview [Go to Page]
- 78.1.4 PHY types optionally supporting EEE
- 80. Introduction to 40 Gb/s and 100 Gb/s networks [Go to Page]
- 80.1 Overview [Go to Page]
- 80.1.3 Relationship of 40 Gigabit and 100 Gigabit Ethernet to the ISO OSI reference model
- 80.1.4 Nomenclature
- 80.1.5 Physical Layer signaling systems
- 80.2 Summary of 40 Gigabit and 100 Gigabit Ethernet sublayers [Go to Page]
- 80.2.3 Forward Error Correction (FEC) sublayers
- 80.4 Delay constraints
- 91. Reed-Solomon Forward Error Correction (RS-FEC) sublayer for 100GBASE-R PHYs [Go to Page]
- 91.5 Functions within the RS-FEC sublayer [Go to Page]
- 91.5.2.7 Reed-Solomon encoder
- 91.5.3 Receive function [Go to Page]
- 91.5.3.3 Reed-Solomon decoder [Go to Page]
- 91.5.3.3.1 FEC Degraded SER (optional)
- 91.6 RS-FEC MDIO function mapping [Go to Page]
- 91.6.2a four_lane_pmd
- 91.7 Protocol implementation conformance statement (PICS) proforma for Clause 91, Reed-Solomon Forward Error Correction (RS-FEC) sublayer for 100GBASE-R PHYs [Go to Page]
- 91.7.3 Major capabilities/options
- 91.7.4 PICS proforma tables for Reed-Solomon Forward Error Correction (RS-FEC) sublayer for 100GBASE-R PHYs [Go to Page]
- 91.7.4.1 Transmit function
- 91.7.4.2 Receive function
- 116. Introduction to 200 Gb/s and 400 Gb/s networks [Go to Page]
- 116.1 Overview [Go to Page]
- 116.1.2 Relationship of 200 Gigabit and 400 Gigabit Ethernet to the ISO OSI reference model
- 116.1.3 Nomenclature
- 116.1.4 Physical Layer signaling systems
- 116.4 Delay constraints
- 116.5 Skew constraints
- 140. Physical Medium Dependent (PMD) sublayer and medium, type 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 [Go to Page]
- 140.1 Overview
- 140.2 Physical Medium Dependent (PMD) service interface
- 140.3 Delay and Skew [Go to Page]
- 140.3.1 Delay constraints
- 140.5 PMD functional specifications [Go to Page]
- 140.5.1 PMD block diagram
- 140.6 PMD to MDI optical specifications for 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 [Go to Page]
- 140.6.1 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 transmitter optical specifications
- 140.6.2 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 receive optical specifications
- 140.6.3 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 illustrative link power budgets
- 140.7 Definition of optical parameters and measurement methods [Go to Page]
- 140.7.1 Test patterns for optical parameters
- 140.7.5 Transmitter and dispersion eye closure for PAM4 (TDECQ) [Go to Page]
- 140.7.5.1 TDECQ reference equalizer
- 140.7.5.2 Channel requirements
- 140.7.5a Transmitter eye closure for PAM4 (TECQ)
- 140.7.5b Over/under-shoot
- 140.7.5c Transmitter power excursion
- 140.7.8 Relative intensity noise (RIN15.5xOMA)
- 140.7.9 Receiver sensitivity [Go to Page]
- 140.7.9.1 Receiver sensitivity for 100GBASE-DR
- 140.7.9.2 Receiver sensitivity for 100GBASE-FR1 and 100GBASE-LR1
- 140.7.10 Stressed receiver sensitivity
- 140.8 Safety, installation, environment, and labeling [Go to Page]
- 140.8.2 Laser safety
- 140.8.4 Environment
- 140.8.5 Electromagnetic emission
- 140.9 Fiber optic cabling model
- 140.10 Characteristics of the fiber optic cabling (channel) [Go to Page]
- 140.10.1 Optical fiber cable
- 140.10.2 Optical fiber connection [Go to Page]
- 140.10.2.1 Connection insertion loss
- 140.10.2.2 Maximum discrete reflectance
- 140.10.3 Medium Dependent Interface (MDI)
- 140.10a Interoperation between 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 [Go to Page]
- 140.10a.1 Interoperation between 100GBASE-FR1 and 100GBASE-DR
- 140.10a.2 Interoperation between 100GBASE-LR1 and 100GBASE-DR
- 140.10a.3 Interoperation between 100GBASE-LR1 and 100GBASE-FR1
- 140.11 Protocol implementation conformance statement (PICS) proforma for Clause 140, Physical Medium Dependent (PMD) sublayer and medium, types 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 [Go to Page]
- 140.11.1 Introduction
- 140.11.2 Identification [Go to Page]
- 140.11.2.2 Protocol summary
- 140.11.3 Major capabilities/options
- 140.11.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 100GBASE-DR, 100GBASE-FR1, and 100GBASE-LR1 [Go to Page]
- 140.11.4.3 PMD to MDI optical specifications for 100GBASE-DR
- 140.11.4.3a PMD to MDI optical specifications for 100GBASE-FR1
- 140.11.4.3b PMD to MDI optical specifications for 100GBASE-LR1
- 140.11.4.4 Optical measurement methods
- 140.11.4.6 Characteristics of the fiber optic cabling and MDMDI .
- 151. Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-FR4 and 400GBASE-LR4-6 [Go to Page]
- 151.1 Overview [Go to Page]
- 151.1.1 Bit error ratio
- 151.2 Physical Medium Dependent (PMD) service interface
- 151.3 Delay and Skew [Go to Page]
- 151.3.1 Delay constraints
- 151.3.2 Skew constraints
- 151.4 PMD MDIO function mapping
- 151.5 PMD functional specifications [Go to Page]
- 151.5.1 PMD block diagram
- 151.5.2 PMD transmit function
- 151.5.3 PMD receive function
- 151.5.4 PMD global signal detect function
- 151.5.5 PMD lane-by-lane signal detect function
- 151.5.6 PMD reset function
- 151.5.7 PMD global transmit disable function (optional)
- 151.5.8 PMD lane-by-lane transmit disable function
- 151.5.9 PMD fault function (optional)
- 151.5.10 PMD transmit fault function (optional)
- 151.5.11 PMD receive fault function (optional)
- 151.6 Wavelength-division-multiplexed lane assignments
- 151.7 PMD to MDI optical specifications for 400GBASE-FR4 and 400GBASE-LR4-6 [Go to Page]
- 151.7.1 400GBASE-FR4 and 400GBASE-LR4-6 transmitter optical specifications
- 151.7.2 400GBASE-FR4 and 400GBASE-LR4-6 receive optical specifications
- 151.7.3 400GBASE-FR4 and 400GBASE-LR4-6 illustrative link power budgets
- 151.8 Definition of optical parameters and measurement methods [Go to Page]
- 151.8.1 Test patterns for optical parameters
- 151.8.2 Wavelength and side mode suppression ratio (SMSR)
- 151.8.3 Average optical power
- 151.8.4 Outer Optical Modulation Amplitude (OMAouter)
- 151.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ) [Go to Page]
- 151.8.5.1 Channel requirements
- 151.8.6 Transmitter eye closure for PAM4 (TECQ)
- 151.8.7 Over/under-shoot
- 151.8.8 Transmitter power excursion
- 151.8.9 Extinction ratio
- 151.8.10 Transmitter transition time
- 151.8.11 Relative intensity noise (RIN17.1OMA and RIN15.6OMA)
- 151.8.12 Receiver sensitivity
- 151.8.13 Stressed receiver sensitivity
- 151.9 Safety, installation, environment, and labeling [Go to Page]
- 151.9.1 General safety
- 151.9.2 Laser safety
- 151.9.3 Installation
- 151.9.4 Environment
- 151.9.5 Electromagnetic emission
- 151.9.6 Temperature, humidity, and handling
- 151.9.7 PMD labeling requirements
- 151.10 Fiber optic cabling model
- 151.11 Characteristics of the fiber optic cabling (channel) [Go to Page]
- 151.11.1 Optical fiber cable
- 151.11.2 Optical fiber connection [Go to Page]
- 151.11.2.1 Connection insertion loss
- 151.11.2.2 Maximum discrete reflectance
- 151.11.3 Medium Dependent Interface (MDI) requirements
- 151.12 Interoperation between 400GBASE-LR4-6 and 400GBASE-FR4
- 151.13 Protocol implementation conformance statement (PICS) proforma for Clause 151, Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-FR4 and 400GBASE-LR4-6 [Go to Page]
- 151.13.1 Introduction
- 151.13.2 Identification [Go to Page]
- 151.13.2.1 Implementation identification
- 151.13.2.2 Protocol summary
- 151.13.3 Major capabilities/options
- 151.13.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-FR4 and 400GBASE-LR4-6 [Go to Page]
- 151.13.4.1 PMD functional specifications
- 151.13.4.2 Management functions
- 151.13.4.3 PMD to MDI optical specifications for 400GBASE-FR4
- 151.13.4.4 PMD to MDI optical specifications for 400GBASE-LR4-6
- 151.13.4.5 Optical measurement methods
- 151.13.4.6 Environmental specifications
- 151.13.4.7 Characteristics of the fiber optic cabling and MDI
- Back Cover [Go to Page]