Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

New York City Mechanical Code, 2022
- 2022 NEW YORK CITY MECHANICAL CODE
- 2022 NEW YORK CITY MECHANICAL CODE TITLE PAGE
- COPYRIGHT
- DEDICATION
- NEW YORK CITY CONSTRUCTION CODES PREFACE
- ACKNOWLEDGEMENTS
- TITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES
- TITLE 28 NEW YORK CITY CONSTRUCTION CODES
- TABLE OF CONTENTS
- CHAPTER 1 ADMINISTRATION [Go to Page]
- SECTION MC 101 GENERAL
- SECTION MC 102 APPLICABILITY
- SECTION MC 103 DEPARTMENT OF BUILDINGS
- SECTION MC 104 DUTIES AND POWERS OF THE COMMISSIONER OF BUILDINGS
- SECTION MC 105 APPROVALS
- SECTION MC 106 PERMITS
- SECTION MC 107 CONSTRUCTION DOCUMENTS
- SECTION MC 108 INSPECTIONS AND TESTING
- SECTION MC 109 VIOLATIONS
- CHAPTER 2 DEFINITIONS [Go to Page]
- SECTION MC 201 GENERAL
- SECTION MC 202 GENERAL DEFINITIONS
- CHAPTER 3 GENERAL REGULATIONS [Go to Page]
- SECTION MC 301 GENERAL
- SECTION MC 302 STRUCTURAL SAFETY
- SECTION MC 303 EQUIPMENT AND APPLIANCE LOCATION
- SECTION MC 304 INSTALLATION
- SECTION MC 305 PIPING SUPPORT [Go to Page]
- TABLE 305.4 PIPING SUPPORT SPACINGa
- SECTION MC 306 ACCESS AND SERVICE SPACE
- SECTION MC 307 CONDENSATE DISPOSAL [Go to Page]
- TABLE 307.2.2 CONDENSATE DRAIN SIZING
- SECTION MC 308 CLEARANCE REDUCTION [Go to Page]
- TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
- SECTION MC 309 TEMPERATURE CONTROL
- SECTION MC 310 EXPLOSION CONTROL
- SECTION MC 311 SMOKE AND HEAT VENTS
- SECTION MC 312 HEATING AND COOLING LOAD CALCULATIONS
- SECTION MC 313 NOISE CONTROL AND VIBRATION ISOLATION REQUIREMENTS
- CHAPTER 4 VENTILATION [Go to Page]
- SECTION MC 401 GENERAL [Go to Page]
- TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
- SECTION MC 402 NATURAL VENTILATION
- SECTION MC 403 MECHANICAL VENTILATION [Go to Page]
- TABLE 403.3.1.1 MINIMUM VENTILATION RATES [Go to Page]
- TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
- TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
- TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
- TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
- EQUATION 4-1
- TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
- EQUATION 4-2
- EQUATION 4-3
- EQUATION 4-4
- EQUATION 4-5
- TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
- EQUATION 4-6
- EQUATION 4-7
- EQUATION 4-8
- EQUATION 4-9
- SECTION MC 404 ENCLOSED PARKING GARAGES
- SECTION MC 405 SYSTEMS CONTROL
- SECTION MC 406 VENTILATION OF UNINHABITED SPACES
- SECTION MC 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
- SECTION MC 408 VENTILATION OF NONPRODUCTION CHEMICAL LABORATORIES
- CHAPTER 5 EXHAUST SYSTEMS [Go to Page]
- SECTION MC 501 GENERAL
- SECTION MC 502 REQUIRED SYSTEMS [Go to Page]
- EQUATION 5-1
- SECTION MC 503 MOTORS AND FANS
- SECTION MC 504 CLOTHES DRYER EXHAUST [Go to Page]
- TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
- SECTION MC 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
- SECTION MC 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
- SECTION MC 507 COMMERCIAL KITCHEN HOODS [Go to Page]
- TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
- SECTION MC 508 COMMERCIAL KITCHEN MAKEUP AIR
- SECTION MC 509 FIRE SUPPRESSION SYSTEMS
- SECTION MC 510 HAZARDOUS EXHAUST SYSTEMS [Go to Page]
- TABLE 510.9 MINIMUM DUCT THICKNESS
- TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
- SECTION MC 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS [Go to Page]
- TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL DUST, STOCK AND REFUSE CONVEYING SYSTEMS
- SECTION MC 512 SUBSLAB SOIL EXHAUST SYSTEMS
- SECTION MC 513 SMOKE CONTROL SYSTEMS
- SECTION MC 514 ENERGY RECOVERY VENTILATION SYSTEMS
- SECTION MC 515 POSTFIRE SMOKE PURGE SYSTEMS
- CHAPTER 6 DUCT SYSTEMS [Go to Page]
- SECTION MC 601 GENERAL
- SECTION MC 602 PLENUMS
- SECTION MC 603 DUCT CONSTRUCTION AND INSTALLATION [Go to Page]
- TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa
- SECTION MC 604 INSULATION
- SECTION MC 605 AIR FILTERS
- SECTION MC 606 SMOKE DETECTION SYSTEMS CONTROL
- SECTION MC 607 DUCTS AND AIR TRANSFER OPENINGS [Go to Page]
- TABLE 607.3.2.1 FIRE DAMPER RATING
- SECTION MC 608 AIR OUTLETS AND AIR INLETS
- SECTION MC 609 SERVICE OPENINGS
- CHAPTER 7 COMBUSTION, VENTILATION, AND DILUTION AIR [Go to Page]
- SECTION MC 701 GENERAL
- SECTION MC 702 INSIDE AIR
- SECTION MC 703 OUTDOOR AIR
- SECTION MC 704 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 1)
- SECTION MC 705 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 2)
- SECTION MC 706 MECHANICAL COMBUSTION AIR SUPPLY
- SECTION MC 707 DIRECT CONNECTION
- SECTION MC 708 COMBUSTION AIR DUCTS
- SECTION MC 709 OPENING OBSTRUCTIONS
- SECTION MC 710 OPENING LOCATION AND PROTECTION
- CHAPTER 8 CHIMNEYS AND VENTS [Go to Page]
- SECTION MC 801 GENERAL [Go to Page]
- EQUATION 8-1
- TABLE 801.21 “F” FACTOR FOR DETERMINING CHIMNEY DISTANCES
- SECTION MC 802 VENTS [Go to Page]
- TABLE 802.2 VENT APPLICATION
- SECTION MC 803 CONNECTORS [Go to Page]
- TABLE 803.8 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
- TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
- TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
- TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
- TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
- SECTION MC 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
- SECTION MC 805 FACTORY-BUILT CHIMNEYS
- SECTION MC 806 METAL CHIMNEYS
- SECTION MC 807 CHANGES IN APPLIANCE FUELS
- SECTION MC 808 REDUCTION OF FLUE SIZE
- SECTION MC 809 CHIMNEY SUPPORTED FROM EQUIPMENT
- SECTION MC 810 TEST RUN AND SMOKE TEST
- SECTION MC 811 EXHAUST GASES FROM INTERNAL COMBUSTION ENGINES AND TURBINES
- CHAPTER 9 SPECIFIC APPLIANCES AND EQUIPMENT [Go to Page]
- SECTION MC 901 GENERAL
- SECTION MC 902 MASONRY FIREPLACES
- SECTION MC 903 FACTORY-BUILT FIREPLACES
- SECTION MC 904 PELLET FUEL-BURNING APPLIANCES
- SECTION MC 905 FIREPLACE STOVES AND ROOM HEATERS
- SECTION MC 906 FACTORY-BUILT BARBECUE APPLIANCES
- SECTION MC 907 INCINERATORS AND CREMATORIES
- SECTION MC 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
- SECTION MC 909 VENTED WALL FURNACES
- SECTION MC 910 FLOOR FURNACES
- SECTION MC 911 DUCT FURNACES AND HEATERS
- SECTION MC 912 INFRARED RADIANT HEATERS
- SECTION MC 913 CLOTHES DRYERS
- SECTION MC 914 SAUNA HEATERS
- SECTION MC 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
- SECTION MC 916 POOL AND SPA HEATERS
- SECTION MC 917 COOKING APPLIANCES
- SECTION MC 918 FORCED-AIR WARM-AIR FURNACES
- SECTION MC 919 CONVERSION BURNERS
- SECTION MC 920 UNIT HEATERS
- SECTION MC 921 VENTED ROOM HEATERS
- SECTION MC 922 KEROSENE AND OIL-FIRED STOVES
- SECTION MC 923 CERAMIC KILNS
- SECTION MC 924 STATIONARY FUEL CELL POWER PLANTS
- SECTION MC 925 MASONRY HEATERS
- SECTION MC 926 GASEOUS HYDROGEN SYSTEMS
- SECTION MC 927 ELECTRIC RADIANT HEATING SYSTEMS
- SECTION MC 928 EVAPORATIVE COOLERS
- CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS [Go to Page]
- SECTION MC 1001 GENERAL
- SECTION MC 1002 WATER HEATERS
- SECTION MC 1003 PRESSURE VESSELS
- SECTION MC 1004 BOILERS [Go to Page]
- TABLE 1004.3.1 BOILER TOP CLEARANCES
- SECTION MC 1005 BOILER CONNECTIONS
- SECTION MC 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
- SECTION MC 1007 BOILER LOW-WATER CUTOFF
- SECTION MC 1008 BOILER BLOWOFF/BLOWDOWN VALVES
- SECTION MC 1009 HOT WATER BOILER EXPANSION TANK [Go to Page]
- EQUATION 10-1
- TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
- SECTION MC 1010 GAUGES
- SECTION MC 1011 TESTS
- SECTION MC 1012 MAXIMUM TEMPERATURE
- CHAPTER 11 REFRIGERATION [Go to Page]
- SECTION MC 1101 GENERAL
- SECTION MC 1102 SYSTEM REQUIREMENTS
- SECTION MC 1103 REFRIGERATION SYSTEM CLASSIFICATION [Go to Page]
- TABLE 1103.1 REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa [Go to Page]
- TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
- TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
- TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
- TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
- SECTION MC 1104 SYSTEM APPLICATION REQUIREMENTS [Go to Page]
- TABLE 1104.3.1 SPECIAL QUANTITY LIMITS FOR SEALED AMMONIA/WATER ABSORPTION AND SELF-CONTAINED SYSTEMS
- SECTION MC 1105 MACHINERY ROOM, GENERAL REQUIREMENTS [Go to Page]
- EQUATION 11-1
- EQUATION 11-2
- SECTION MC 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
- SECTION MC 1107 REFRIGERANT PIPING
- SECTION MC 1108 FIELD TEST
- SECTION MC 1109 PERIODIC TESTING
- CHAPTER 12 HYDRONIC PIPING [Go to Page]
- SECTION MC 1201 GENERAL
- SECTION MC 1202 MATERIAL [Go to Page]
- TABLE 1202.4 HYDRONIC PIPE [Go to Page]
- TABLE 1202.4 HYDRONIC PIPE—continued
- TABLE 1202.5 HYDRONIC PIPE FITTINGS
- SECTION MC 1203 JOINTS AND CONNECTIONS
- SECTION MC 1204 PIPE INSULATION
- SECTION MC 1205 VALVES
- SECTION MC 1206 PIPING INSTALLATION
- SECTION MC 1207 TRANSFER FLUID
- SECTION MC 1208 TESTS
- SECTION MC 1209 EMBEDDED PIPING
- SECTION MC 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS [Go to Page]
- TABLE 1210.4 GROUND-SOURCE LOOP PIPE
- TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
- SECTION MC 1211 HIGH-PRESSURE STEAM AND HIGH TEMPERATURE HOT WATER PIPING SYSTEMS
- CHAPTER 13 FUEL-OIL PIPING AND STORAGE [Go to Page]
- SECTION MC 1301 GENERAL
- SECTION MC 1302 MATERIAL [Go to Page]
- TABLE 1302.3 FUEL-OIL PIPING
- TABLE 1302.5 PIPE FITTINGS
- SECTION MC 1303 JOINTS AND CONNECTIONS
- SECTION MC 1304 PIPING SUPPORT
- SECTION MC 1305 FUEL-OIL SYSTEM INSTALLATION [Go to Page]
- TABLE 1305.7(1) VENT PIPING FOR UNDERGROUND TANKS
- TABLE 1305.7(2) NORMAL VENT PIPING FOR TANKS INSTALLED INSIDE BUILDINGS
- EQUATION 13-1
- EQUATION 13-2
- SECTION MC 1306 OIL GAUGING
- SECTION MC 1307 FUEL-OIL VALVES
- SECTION MC 1308 TESTING
- CHAPTER 14 SOLAR SYSTEMS [Go to Page]
- SECTION MC 1401 GENERAL
- SECTION MC 1402 INSTALLATION
- SECTION MC 1403 HEAT TRANSFER FLUIDS
- SECTION MC 1404 MATERIALS
- CHAPTER 15 REFERENCED STANDARDS [Go to Page]
- SECTION MC 1501 GENERAL
- SECTION MC 1502 STANDARDS [Go to Page]
- ACCA
- AHRI
- AMCA
- ANSI
- ASHRAE
- ASME
- ASNT
- ASSE
- ASTM
- AWS
- AWWA
- BSI
- CAN/ULC
- CSA
- DOL
- EN
- IIAR
- MSS
- NAIMA
- NBBI
- NFPA
- NSF
- SMACNA
- UL
- APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS [Go to Page]
- FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS [Go to Page]
- FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
- APPENDIX B RESERVED
- APPENDIX C FUEL OIL STORAGE TANK VENTING OPTIONS [Go to Page]
- SECTION MC C101 GENERAL [Go to Page]
- FIGURE C101.1(1) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK
- FIGURE C101.1(2) PRIMARY TANK: UL 142 OR DUAL LABEL TANK DAY TANK: UL 142 OR DUAL LABEL TANK
- FIGURE C101.1(3) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 142 OR DUAL LABEL TANK
- INDEX RESERVED
- ICC DIGITAL CODES PREMIUM
- ICC ASSESSMENT CENTER
- ICC LEARNING CENTER
- ICC EVALUATION SERVICE [Go to Page]