Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS EN 267:2020 Forced draught burners for liquid fuels, 2020
- undefined
- 1 Scope
- 2 Normative references
- 3 Terms and definitions [Go to Page]
- 3.1 General definitions
- 3.2 Fuel flow rate and heat input
- 3.3 Combustion chamber, burner head and test rig
- 3.4 Composition of the gaseous combustion products
- 3.5 Adjusting, control and safety devices
- 3.6 Sequencing
- 3.7 Diagrams
- 4 Classification, constructional and operational requirements – safety requirements and/or protective measures [Go to Page]
- 4.1 Types of atomization [Go to Page]
- 4.1.1 Mechanical atomization by pressurization of the combustion liquid
- 4.1.2 Atomization by auxiliary fluid
- 4.2 Methods of control of automatic or semi-automatic oil burners [Go to Page]
- 4.2.1 On-off control (single stage burner)
- 4.2.2 Multi-stage control (two and multi-stage burner)
- 4.2.3 Modulating control (modulating burner)
- 4.3 Means of ignition [Go to Page]
- 4.3.1 Automatic electric ignition [Go to Page]
- 4.3.1.1 General
- 4.3.1.2 Ignition by controlled spark
- 4.3.1.3 Ignition by non-controlled spark
- 4.3.2 Automatic ignition with liquid or gaseous fuels [Go to Page]
- 4.3.2.1 General
- 4.3.2.2 Ignition by controlled ignition burner
- 4.3.2.3 Ignition by non-controlled ignition burner
- 4.4 Construction [Go to Page]
- 4.4.1 General
- 4.4.2 Design [Go to Page]
- 4.4.2.1 Design related to combustion
- 4.4.2.2 Mechanical safety and stability
- 4.4.3 Accessibility for maintenance and use
- 4.4.4 Soundness
- 4.4.5 Materials
- 4.4.6 Mounting
- 4.4.7 Connections
- 4.4.8 Pressure test points
- 4.5 Equipment [Go to Page]
- 4.5.1 Motors, fans and movable parts
- 4.5.2 Electrical safety
- 4.5.3 Air flow control device
- 4.5.4 Fuel line components [Go to Page]
- 4.5.4.1 General
- 4.5.4.2 Manually operated shut-off valve
- 4.5.4.3 Filter and venting device
- 4.5.4.4 Fuel pressure or flow adjustment device
- 4.5.4.5 Safety shut-off devices
- 4.5.5 Fuel preheating [Go to Page]
- 4.5.5.1 General
- 4.5.5.2 Heat sources
- 4.5.5.3 Preheating temperature
- 4.5.5.4 Control of preheating temperature
- 4.5.5.5 Pressurized preheaters
- 4.5.6 Ignition device [Go to Page]
- 4.5.6.1 General
- 4.5.6.2 Flame detector device
- 4.5.6.3 Air proving device
- 4.5.6.4 Fuel/air ratio control devices
- 4.5.7 Automatic burner control unit
- 4.6 Functional and operational requirements [Go to Page]
- 4.6.1 General function requirements [Go to Page]
- 4.6.1.1 General
- 4.6.1.2 Burner start-up
- 4.6.1.3 Pre-purge
- 4.6.2 Ensuring adequate oil pre-heating
- 4.6.3 Start heat input and safety times
- 4.6.4 Non-volatile lock-out, recycling and ignition restoration of the oil burner
- 4.6.5 Start gas ignition
- 4.6.6 Main burner ignition
- 4.6.7 Energizing of the safety shut-off valve for the oil supply
- 4.6.8 Flame failure response time
- 4.6.9 Total closing time
- 4.6.10 Burner shut-down [Go to Page]
- 4.6.10.1 General
- 4.6.10.2 Protection of the oil and air supply
- 4.6.11 Resistance of the burner to over-heating
- 4.6.12 Temperatures of the control and safety devices
- 4.6.13 Surface temperature
- 4.6.14 Ignition, operation and flame stability
- 4.6.15 Heat input range of the burner
- 4.6.16 Dual-fuel burner
- 4.6.17 Remote reset from lock-out
- 4.7 Working diagram and test diagram [Go to Page]
- 4.7.1 Working diagram
- 4.7.2 Test diagram
- 4.7.3 Diagrams
- 4.7.4 Determination of the flame stability and safe range of operation
- 4.8 Combustion products quality [Go to Page]
- 4.8.1 Combustion
- 4.8.2 Measurements
- 4.8.3 Smoke number (see Annex A)
- 4.8.4 Unburned hydrocarbons (see Annex D)
- 4.8.5 Emission classes for NOX and CO [Go to Page]
- 4.8.5.1 General
- 4.8.5.2 Heat input ≤ 400 kW (ErP)
- 4.8.6 Starting characteristics
- 4.8.7 Combustion quality of the combustion products for other liquid fuels
- 4.8.8 Excess air ratio λ
- 4.9 Machine safety requirements and/or protective measures
- 5 Testing [Go to Page]
- 5.1 General [Go to Page]
- 5.1.1 Verification of burner design and combustion testing
- 5.1.2 Verification of machine safety
- 5.2 Test room
- 5.3 Test rig [Go to Page]
- 5.3.1 General
- 5.3.2 Test rig ≤ 2,4 MW heat input
- 5.3.3 Test rig > 2,4 MW heat input
- 5.4 Measuring equipment [Go to Page]
- 5.4.1 General
- 5.4.2 Determination of the CO2 or O2 as well as NOx, CO and CxHy contents of the combustion gases
- 5.4.3 Determination of the smoke number
- 5.5 Measuring accuracy [Go to Page]
- 5.5.1 Measurement accuracy of the measuring devices
- 5.5.2 Measurement accuracy during test
- 5.6 Test conditions [Go to Page]
- 5.6.1 Fuel to be used
- 5.6.2 Testing
- 5.7 Test programme [Go to Page]
- 5.7.1 Structural testing
- 5.7.2 Functional tests [Go to Page]
- 5.7.2.1 General
- 5.7.2.2 Start-up
- 5.7.2.3 Pre-purge
- 5.7.2.4 Ensuring adequate oil pre-heating
- 5.7.2.5 Start-up heat input
- 5.7.3 Starting test
- 5.7.4 Ignition
- 5.7.5 Safety times [Go to Page]
- 5.7.5.1 General
- 5.7.5.2 Safety time during operation
- 5.7.5.3 Failure to ignite
- 5.7.5.4 Total closing time
- 5.7.6 Auxiliary electricity consumption (ErP)
- 5.7.7 Sound power level, Lwa (ErP)
- 5.7.8 Tests to be carried out on soundness and devices [Go to Page]
- 5.7.8.1 External soundness
- 5.7.8.2 Temperature of the control and safety devices
- 5.7.9 Tests to be carried out on the test diagrams [Go to Page]
- 5.7.9.1 Setting and duration
- 5.7.9.2 Tests at test point Hp1
- 5.7.9.3 Tests at test point Hp2
- 5.7.9.4 Tests at test point Hp3
- 5.7.9.5 Tests at test point 1
- 5.7.9.6 Tests at test point 4
- 5.7.9.7 Tests at test point 5
- 5.7.9.8 Tests at test point Hp6
- 5.7.9.9 Summary
- 5.7.9.10 Functional test
- 5.7.10 Result of the completed tests, test report
- 5.7.11 Electrical voltage conditions
- 5.7.12 Testing during continuous operation in the case of multistage or modulating control burners
- 5.7.13 Burners with separate fan
- 5.8 Replacement of individual parts and equivalent components
- 6 Marking and labelling [Go to Page]
- 6.1 General
- 6.2 Data plate
- 6.3 Other marking
- 6.4 Instructions for installation, adjustment, maintenance and operation
- 6.5 Packaging
- Annex A (normative)Smoke number [Go to Page]
- A.1 Apparatus
- A.2 Smoke measuring
- A.3 Determination of the smoke number
- Annex B (normative)Determination of combustion characteristics — Carbon monoxide and nitrogen oxides, conversion and corrections [Go to Page]
- B.1 CO content (), calculation from ml/m3 into mg/kWh
- B.2 NOx content (), calculation from ml/m3 into mg/kWh
- B.3 Correction for the influence of combustion air temperature and humidity on NOx emissions QNOx
- B.4 Correction of the influence of the nitrogen content of fuel oil in case of NOX-emissions
- B.5 NOX mean value for evaluating the NOX classes
- B.6 Other conversion factors for emissions, calculated from ml/m3 into mg/m3 at 3 % O2 reference flue gas conditions
- Annex C (informative)Void
- Annex D (normative)FID measuring method for recording the unburned hydrocarbons [Go to Page]
- D.1 Measuring system
- D.2 Starting
- Annex E (informative)Conformity evaluation [Go to Page]
- E.1 Test laboratories and test samples, procedure [Go to Page]
- E.1.1 Test laboratories
- E.1.2 Test samples
- E.2 Types of test and test documents for oil burners [Go to Page]
- E.2.1 Type test
- E.2.2 Type test in the overall system
- E.2.3 Drawing test
- E.2.4 Supplementary test
- E.2.5 Test documentation for oil burners
- Annex F (informative)Examples for equipping of burners [Go to Page]
- F.1 Burners ≤ 400 kW
- F.2 Burners > 400 kW
- Annex G (informative)Other fuels
- Annex H (informative)Specific additional requirements and limitations for use of EN 267 burners for industrial applications [Go to Page]
- H.1 Pre-heating of the combustion air
- H.2 Continuous working of the forced draught fan
- H.3 Variable excess of combustion air
- H.4 Burner with spark ignition
- H.5 Air filtering
- H.6 Electrical equipment and EMC-compatibility
- Annex I (informative)Check of the air proving device
- Annex J (normative)Machine related hazards - additional safety requirements and/or protective measures) [Go to Page]
- J.1 General
- J.2 List of significant hazards
- J.3 Safety requirements and /or protective measures [Go to Page]
- J.3.1 General
- J.3.2 Additional requirements [Go to Page]
- J.3.2.1 Mechanical safety, stability and control devices
- J.3.2.2 Motors, fans and movable parts
- J.3.2.3 Electrical safety
- J.3.2.4 Noise reduction
- J.4 Verification of machine safety requirements and/or protective measures
- J.5 Information for use [Go to Page]
- J.5.1 General
- J.5.2 Instructions for installation, adjustment, maintenance
- Annex K (normative)Additional requirements for burners with pressurized parts and burners firing pressurized bodies as defined in the Pressure Equipment Directive (PED) 2014/68/EU [Go to Page]
- K.1 General
- K.2 Pressurized parts [Go to Page]
- K.2.1 Design
- K.2.2 Materials
- K.2.3 Permanent joints
- K.3 Electrical safety and fuel line components [Go to Page]
- K.3.1 Electrical safety
- K.3.2 Fuel line components
- K.4 Air proving device
- K.5 Automatic burner control unit
- K.6 General functions requirements
- K.7 Protection of the oil and air supply
- K.8 External safety limiter
- K.9 Design according to Annex L in conjunction with EN 602041:2006 [Go to Page]
- K.9.1 General
- K.9.2 Pressure control
- K.9.3 Burner control and flame detection
- K.9.4 Safe shut-off of the oil supply
- K.9.5 Fuel/air ratio control
- K.9.6 Integration of the superior safety equipment of the boiler and of the firing system
- K.10 Consideration: Safety life cycle
- K.11 Tests of pressurized parts [Go to Page]
- K.11.1 Component pressure strength test
- K.11.2 Component design mechanical deformation test
- K.11.3 Component design welded joint test
- K.11.4 External soundness
- K.12 Marking [Go to Page]
- K.12.1 Data plate
- K.12.2 Other marking
- K.13 Instructions for installation, adjustment, maintenance and operation
- Annex L (normative)Electrical requirements – modifications to EN 60204-1 [Go to Page]
- L.1 Scope
- L.2 Normative references
- L.3 Terms and definitions [Go to Page]
- L.3.1 Protective system
- L.3.2 Safety device
- L.3.3 Sensor
- L.3.4 Protective equipment
- L.3.5 Actuating element
- L.3.6 Control system
- L.4 General requirements [Go to Page]
- L.4.1 General
- L.4.2 Selection of equipment
- L.4.3 Electrical supply
- L.4.4 Physical environment and operating condition [Go to Page]
- L.4.4.1 General
- L.4.4.2 Electromagnetic compatibility (EMC)
- L.4.4.3 Ambient air temperature
- L.4.4.4 Humidity
- L.4.4.5 Altitude
- L.4.4.6 Contaminants
- L.4.4.7 Ionizing and non-ionizing radiation
- L.4.4.8 Vibration, shock, and bump
- L.4.4.9 Equipment used in flammable atmospheres
- L.5 Incoming supply conductor terminations and devices for disconnecting and switching off
- L.6 Protection against electric shock [Go to Page]
- L.6.1 General
- L.6.2 Protection against direct contact
- L.7 Protection of equipment
- L.8 Equipotential bonding
- L.9 Control circuits and control functions [Go to Page]
- L.9.1 Control circuits [Go to Page]
- L.9.1.1 Control circuit supply
- L.9.1.2 Control circuit voltages
- L.9.2 Control functions [Go to Page]
- L.9.2.1 Start functions
- L.9.3 Protective interlocks
- L.9.4 Control functions in the event of failure (Protective system) [Go to Page]
- L.9.4.1 General requirements
- L.9.4.2 Measures to minimize risk in the event of failure
- L.9.4.3 Protection against maloperation due to earth faults, voltage interruptions and loss of circuit continuity
- L.9.4.4 Classification of protective systems
- L.9.4.5 Safety lifecycle for protective systems
- L.9.4.6 Determination of the safety level (PL / SIL) for protective functions
- L.9.4.7 Hardware design of protective systems
- L.9.4.8 Application software for PLC based protective systems
- L.9.4.9 Installation and commissioning
- L.9.4.10 Safety validation of protective systems
- L.9.4.11 Modification and retrofit
- L.10 Operator interface and machine-mounted control devices-
- L.11 Electrical equipment (Controlgear: location, mounting, and enclosures) [Go to Page]
- L.11.1 Degrees of protection
- L.11.2 Access to controlgear
- L.11.3 Creepage distances and clearances
- L.11.4 Transformers
- L.11.5 Switching devices
- L.11.6 Trace heating systems
- L.12 Conductors and cables
- L.13 Wiring practices [Go to Page]
- L.13.1 Conductors of different circuits
- L.14 Electric motors and associated equipment
- L.15 Accessories and lighting [Go to Page]
- L.15.1 Accessories
- L.15.2 Local lighting of the machine and equipment
- L.16 Marking, warning signs and reference designations
- L.17 Technical documentation
- L.18 Verification
- Annex M (normative)Equipment to increase the efficiency of the burner - boiler installation
- Annex N (informative)Electrical interfaces for burners
- Annex O (informative)Environmental checklist EN 267
- Annex P (informative)Guide for the applicability of the different standards on electrical safety
- Annex Q (informative)Verification procedures for market surveillance purposes (ErP) [Go to Page]
- Q.1 General
- Q.2 Minimisation of the influence of the measurement procedure
- Q.3 Verification of the declared parameters
- Annex ZA (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 813/2013 aimed to be covered [Go to Page]