Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

ACI CODE-440.11-22: Building Code Requirements for Structural Concrete Reinforced with Glass Fiber-Reinforced Polymer (GFRP) Bars—Code and Commentary with Errata as of March 13 2023, 2022
- TITLE PAGE
- PREFACE
- CHAPTER 1—GENERAL [Go to Page]
- 1.1—Scope of ACI CODE-440.11-22
- 1.2—General
- 1.3—Purpose
- 1.4—Applicability
- 1.5—Interpretation
- 1.6—Building official
- 1.7—Licensed design professional
- 1.8—Construction documents and design records
- 1.9—Testing and inspection
- 1.10—Approval of special systems of design, construction, or alternative construction materials
- CHAPTER 2—NOTATION AND TERMINOLOGY [Go to Page]
- 2.1—Scope
- 2.2—Notation
- 2.3—Terminology
- CHAPTER 3—REFERENCED STANDARDS [Go to Page]
- 3.1—Referenced standards
- CHAPTER 4—STRUCTURAL SYSTEM REQUIREMENTS [Go to Page]
- 4.1—Scope
- 4.2—Materials
- 4.3—Design loads
- 4.4—Structural system and load paths
- 4.5—Structural analysis
- 4.6—Strength
- 4.7—Serviceability
- 4.8—Durability
- 4.9—Sustainability
- 4.10—Structural integrity
- 4.11—Fire resistance and elevated service temperature
- 4.12—Requirements for specific types of construction
- 4.13—Construction and inspection
- 4.14—Strength evaluation of existing structures
- CHAPTER 5—LOADS [Go to Page]
- 5.1—Scope
- 5.2—General
- 5.3—Load factors and combinations
- CHAPTER 6—STRUCTURAL ANALYSIS [Go to Page]
- 6.1—Scope
- 6.2—General
- 6.3—Modeling assumptions
- 6.4—Arrangement of live load
- 6.5—Simplified method of analysis for continuous beams and one-way slabs
- 6.6—First-order analysis
- 6.7—Linear elastic second-order analysis
- 6.8—Inelastic analysis—Out of scope
- 6.9—Acceptability of finite element analysis
- 6.8—Inelastic analysis
- CHAPTER 7—ONE-WAY SLABS [Go to Page]
- 7.1—Scope
- 7.2—General
- 7.3—Design limits
- 7.4—Required strength
- 7.5—Design strength
- 7.6—GFRP reinforcement limits
- 7.7—GFRP reinforcement detailing
- CHAPTER 8—TWO-WAY SLABS [Go to Page]
- 8.1—Scope
- 8.2—General
- 8.3—Design limits
- 8.4—Required strength
- 8.5—Design strength
- 8.6—GFRP reinforcement limits
- 8.7—GFRP reinforcement detailing
- 8.8—Nonprestressed two-way joist systems—Out of scope
- 8.9—Lift-slab construction—Out of scope
- CHAPTER 9—BEAMS [Go to Page]
- 9.1—Scope
- 9.2—General
- 9.3—Design limits
- 9.4—Required strength
- 9.5—Design strength
- 9.6—GFRP reinforcement limits
- 9.7—GFRP reinforcement detailing
- 9.8—One-way joist systems
- 9.9—Deep beams—Out of scope
- CHAPTER 10—COLUMNS [Go to Page]
- 10.1—Scope
- 10.2—General
- 10.3—Design limits
- 10.4—Required strength
- 10.5—Design strength
- 10.6—GFRP reinforcement limits
- 10.7—GFRP reinforcement detailing
- CHAPTER 11—WALLS [Go to Page]
- 11.1—Scope
- 11.2—General
- 11.3—Design limits
- 11.4—Required strength
- 11.5—Design strength
- 11.6—GFRP reinforcement limits
- 11.7—GFRP reinforcement detailing
- 11.8—Alternative method for out-of-plane slender wall analysis—Out of scope
- CHAPTER 12—DIAPHRAGMS—NOT ADDRESSED
- CHAPTER 13—FOUNDATIONS [Go to Page]
- 13.1—Scope
- 13.2—General
- 13.3—Shallow foundations
- 13.4—Deep foundations
- CHAPTER 14—PLAIN CONCRETE—NOT APPLICABLE
- CHAPTER 15—BEAM-COLUMN AND SLAB-COLUMN JOINTS [Go to Page]
- 15.1—Scope
- 15.2—General
- 15.3—Transfer of column axial force through the floor system
- 15.4—Detailing of joints
- CHAPTER 16—CONNECTIONS BETWEEN MEMBERS [Go to Page]
- 16.1—Scope
- 16.2—Connections of precast members—Out of scope
- 16.3—Connections to foundations
- 16.4—Horizontal shear transfer in composite concrete flexural members
- 16.5—Brackets and corbels—Out of scope
- CHAPTER 17—ANCHORING TO CONCRETE—NOT ADDRESSED
- CHAPTER 18—EARTHQUAKE-RESISTANT STRUCTURES—NOT ADDRESSED
- CHAPTER 19—CONCRETE: DESIGN AND DURABILITY REQUIREMENTS [Go to Page]
- 19.1—Scope
- 19.2—Concrete design properties
- 19.3—Concrete durability requirements
- 19.4—Grout durability requirements—Out of scope
- CHAPTER 20—GFRP REINFORCEMENT PROPERTIES, DURABILITY, AND EMBEDMENTS [Go to Page]
- 20.1—Scope
- 20.2—GFRP bars
- 20.3—Prestressing strands, wires, and bars—Out of scope
- 20.4—Headed shear stud reinforcement—Out of scope
- 20.5—Provisions for durability of GFRP reinforcement
- 20.6—Embedments
- CHAPTER 21—STRENGTH REDUCTION FACTORS [Go to Page]
- 21.1—Scope
- 21.2—Strength reduction factors for structural concrete members and connections
- CHAPTER 22—SECTIONAL STRENGTH [Go to Page]
- 22.1—Scope
- 22.2—Design assumptions for moment and axial strength
- 22.3—Flexural strength
- 22.4—Axial strength or combined flexural and axial strength
- 22.5—One-way shear strength
- 22.6—Two-way shear strength
- 22.7—Torsional strength
- 22.8—Bearing
- 22.9—Shear friction—Out of scope
- CHAPTER 23—STRUT-AND-TIE METHOD—NOT ADDRESSED
- CHAPTER 24—SERVICEABILITY REQUIREMENTS [Go to Page]
- 24.1—Scope
- 24.2—Deflections due to service-level gravity loads
- 24.3—Distribution of GFRP flexural reinforcement in one-way slabs and beams
- 24.4—GFRP shrinkage and temperature reinforcement
- 24.5—Permissible stresses in prestressed concrete flexural members—Out of scope
- 24.6—Permissible tensile stresses in GFRP reinforcement
- CHAPTER 25—GFRP REINFORCEMENT DETAILS [Go to Page]
- 25.1—Scope
- 25.2—Minimum spacing of GFRP reinforcement
- 25.3—Standard hooks, crossties, and minimum inside bend diameters
- 25.4—Development of GFRP reinforcement
- 25.5—Splices
- 25.6—Bundled reinforcement—Out of scope
- 25.7—GFRP transverse reinforcement
- 25.8—Post-tensioning anchorages and couplers—Out of scope
- 25.9—Anchorage zones for post-tensioned tendons—Out of scope
- CHAPTER 26—CONSTRUCTION DOCUMENTS AND INSPECTION [Go to Page]
- 26.1—Scope
- 26.2—Design criteria
- 26.3—Member information
- 26.4—Concrete materials and mixture requirements
- 26.5—Concrete production and construction
- 26.6—GFRP reinforcement materials and construction requirements
- 26.7—Anchoring to concrete—Out of scope
- 26.8—Embedments
- 26.9—Additional requirements for precast concrete
- 26.10—Additional requirements for prestressed concrete—Out of scope
- 26.11—Formwork
- 26.12—Evaluation and acceptance of hardended concrete
- 26.13—Inspection
- CHAPTER 27—STRENGTH EVALUATION OF EXISTING CONCRETE STRUCTURES [Go to Page]
- 27.1—Scope
- 27.2—General
- 27.3—Analytical strength evaluation
- 27.4—Strength evaluation by load test
- 27.5—Monotonic load test procedure
- APPENDIX—EQUIVALENCE BETWEEN SI-METRIC, MSK-METRIC, AND U.S. CUSTOMARY UNITS OF NONHOMOGENOUS EQUATIONS IN THE CODE
- COMMENTARY REFERENCES [Go to Page]
- Authored documents [Go to Page]