Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

Maximizing Envelope Performance with IMP-Integrated Components, 2025
- Slide 1
- Slide 2: Maximizing Envelope Performance with IMP-Integrated Components
- Slide 3
- Slide 4
- Slide 5: How to Use This Online Learning Course
- Slide 6: Purpose and Learning Objectives
- Slide 7: Contents
- Slide 8: Achieving a High-Performance Building Envelope
- Slide 9: Introduction
- Slide 10: Defining a High-Performance Building Envelope
- Slide 11: Achieving a High-Performance Building Envelope
- Slide 12: Barriers to Achieving a High-Performance Building Envelope
- Slide 13: Barriers to Achieving a High-Performance Building Envelope
- Slide 14: Who Is Responsible?
- Slide 15: Features & Benefits of Today’s Insulated Metal Panel System
- Slide 16: Defining an Insulated Metal Panel (IMP)
- Slide 17: Characteristics of an IMP System
- Slide 18: Continuous Air Barrier
- Slide 19: Continuous Water Barrier
- Slide 20: Thermal Barrier
- Slide 21: Vapor Barrier
- Slide 22: Insulation
- Slide 23: Comparison of Thermal Insulation
- Slide 24: Halogen-Free PIR
- Slide 25: Foamed-in-Place vs. Laminated
- Slide 26: Thermally Improved Horizontal Joint
- Slide 27: Horizontal Pressure-Equalized Rainscreen Joinery
- Slide 28: Horizontal Pressure-Equalized Rainscreen Joinery
- Slide 29: Vertical Insulated & Pressure-Equalized Rainscreen Joinery
- Slide 30: Design Flexibility
- Slide 31: Design Flexibility
- Slide 32: Integrated Envelope Components
- Slide 33: Review Question
- Slide 34: Answer
- Slide 35: IMP-Integrated Windows
- Slide 36: IMP-Integrated Windows: Introduction
- Slide 37: Variety of Models
- Slide 38: Head Integration
- Slide 39: Sill Integration
- Slide 40: Thermal Performance Comparison at Window Head
- Slide 41: Thermal Performance Comparison at Windowsill
- Slide 42: Window Head: Nonintegrated vs. Integrated Window
- Slide 43: Windowsill: Nonintegrated vs. Integrated Window
- Slide 44: Thermal Performance Comparison at Jamb
- Slide 45: Examples of IMP-Integrated Window Installations
- Slide 46: Examples of IMP-Integrated Window Installations
- Slide 47: IMP-Integrated Sunshades
- Slide 48: IMP-Integrated Sunshades: Introduction
- Slide 49: Benefits of Exterior Sunshades
- Slide 50: Exterior Sunshades vs. Interior Sunshades
- Slide 51: Exterior Sunshades vs. Interior Sunshades
- Slide 52: Installation of IMP-Integrated Sunshades
- Slide 53: Installation of IMP-Integrated Sunshades
- Slide 54: Outrigger Profile Options
- Slide 55: Fascia Options
- Slide 56: Blade Options
- Slide 57: Infill Options
- Slide 58: Examples of IMP-Integrated Sunshade Applications
- Slide 59: Examples of IMP-Integrated Sunshade Applications
- Slide 60: IMP-Integrated Translucent Daylighting Panels
- Slide 61: IMP-Integrated Translucent Daylighting Panels: Introduction
- Slide 62: The Benefits of Using IMP-Integrated Translucent Daylighting Panels
- Slide 63: Integration Details
- Slide 64: Examples: IMP-Integrated Translucent Daylighting Panels
- Slide 65: Examples: IMP-Integrated Translucent Daylighting Panels
- Slide 66: Review Question
- Slide 67: Answer
- Slide 68: IMP-Integrated Louvers
- Slide 69: IMP-Integrated Louvers: Introduction
- Slide 70: IMP-Integrated Louvers: Head, Sill, & Jamb Details
- Slide 71: Aesthetic Feature
- Slide 72: Blank-Off Panels
- Slide 73: Blank-Off Panels
- Slide 74: IMP-Integrated Vertical Tube Support & Accent Fins
- Slide 75: IMP-Integrated Vertical Tube Support: Introduction
- Slide 76: Live-Load Floor Deflection
- Slide 77: Deflection Joint Solutions
- Slide 78: Possible Solutions
- Slide 79: Through-Tube Bypass Framing Solution
- Slide 80: Installation: IMP-Integrated Vertical Tube Support System
- Slide 81: Installation: IMP-Integrated Vertical Tube Support System
- Slide 82: Installation: IMP-Integrated Vertical Tube Support System
- Slide 83: Installation: IMP-Integrated Vertical Tube Support System
- Slide 84: IMP-Integrated Accent Fins
- Slide 85: Review Question
- Slide 86: Answer
- Slide 87: Case Studies
- Slide 88: Saint Joseph’s/Candler Hospital, Savannah, GA
- Slide 89: Saint Joseph’s/Candler Hospital, Savannah, GA
- Slide 90: Saint Joseph’s/Candler Hospital, Savannah, GA
- Slide 91: Saint Joseph’s/Candler Hospital, Savannah, GA
- Slide 92: Saint Joseph’s/Candler Hospital, Savannah, GA
- Slide 93: NYPA Niagara Warehouse & Office Complex, Lewiston, NY
- Slide 94: NYPA Niagara Warehouse & Office Complex, Lewiston, NY
- Slide 95: NYPA Niagara Warehouse & Office Complex, Lewiston, NY
- Slide 96: Butler County Government Center, Butler, PA
- Slide 97: Butler County Government Center, Butler, PA
- Slide 98: Butler County Government Center, Butler, PA
- Slide 99: Summary
- Slide 100: Important Points
- Slide 101: Thank You [Go to Page]