Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
ASME A17.1/CSA B44 Handbook , 2010
- CONTENTS
- INTRODUCTION
- FOREWORD
- ACKNOWLEDGMENTS
- SUMMARY OF CODE CHANGES
- Part 1 GENERAL
[Go to Page]
- SECTION 1.1 SCOPE
- SECTION 1.2 PURPOSE AND EXCEPTIONS
- SECTION 1.3 DEFINITIONS
- Part 2 ELECTRIC ELEVATORS
[Go to Page]
- SECTION 2.1 CONSTRUCTION OF HOISTWAYS AND HOISTWAY ENCLOSURES
- SECTION 2.2 PITS
- SECTION 2.3 LOCATION AND GUARDING OF COUNTERWEIGHTS
- SECTION 2.4 VERTICAL CLEARANCES AND RUNBYS FOR CARS AND COUNTERWEIGHTS
- SECTION 2.5 HORIZONTAL CAR AND COUNTERWEIGHT CLEARANCES
- SECTION 2.6 PROTECTION OF SPACES BELOW HOISTWAYS
- SECTION 2.7 MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS [Go to Page]
- Chart 2.7.1 Machinery Space, Machine Room, Control Space, Control Room, Remote Machine Room, and Remote Control Room
- SECTION 2.8 EQUIPMENT IN HOISTWAYS, MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS [Go to Page]
- Chart 2.8.3.3( a) NFPA 13- 2010, Table 6.2.5.1, Temperature Ratings, Classifications, and Color Coding for Sprinklers
- Chart 2.8.3.3( b) NFPA 72- 2010 Handbook, Temperature Classification for Heat- Sensing Fire Detectors
- SECTION 2.9 MACHINERY AND SHEAVE BEAMS, SUPPORTS, AND FOUNDATIONS
- SECTION 2.10 GUARDING OF EXPOSED EQUIPMENT
- SECTION 2.11 PROTECTION OF HOISTWAY- LANDING OPENINGS
- SECTION 2.12 HOISTWAY- DOOR LOCKING DEVICES AND ELECTRIC CONTACTS, AND HOISTWAY ACCESS SWITCHES
- SECTION 2.13 POWER OPERATION OF HOISTWAY DOORS AND CAR DOORS
- SECTION 2.14 CAR ENCLOSURES, CAR DOORS AND GATES, AND CAR ILLUMINATION
- SECTION 2.15 CAR FRAMES AND PLATFORMS
- SECTION 2.16 CAPACITY AND LOADING
- SECTION 2.17 CAR AND COUNTERWEIGHT SAFETIES [Go to Page]
- Chart 2.17 Safety Retarding Forces
- SECTION 2.18 SPEED GOVERNORS [Go to Page]
- Chart 2.18.4.2( a) Governor Overspeed Switch Settings
- Chart 2.18.4.2( b) Governor Adjustment Settings
- SECTION 2.19 ASCENDING CAR OVERSPEED AND UNINTENDED CAR MOVEMENT PROTECTION [Go to Page]
- Chart 2.19 Traction Elevator Brake Type, Function, and Performance
- Chart 2.19.2.1( a) Car Positions and Description of Events
- Chart 2.19.2.1( b) Summary of Motion Equations
- Chart 2.19.2.1( c) Example Variables
- SECTION 2.20 SUSPENSION MEANS AND THEIR CONNECTIONS [Go to Page]
- Chart 2.20.3 Design Requirements — Traction Elevator Suspension System
- SECTION 2.21 COUNTERWEIGHTS
- SECTION 2.22 BUFFERS AND BUMPERS
- SECTION 2.23 CAR AND COUNTERWEIGHT GUIDE RAILS, GUIDE-RAIL SUPPORTS, AND FASTENINGS
- SECTION 2.24 DRIVING MACHINES AND SHEAVES [Go to Page]
- Chart 2.24.8 Braking System and Driving Machine Brake
- Chart 2.24.8 Braking System and Driving Machine Brake ( Cont'd)
- SECTION 2.25 TERMINAL STOPPING DEVICES
- SECTION 2.26 OPERATING DEVICES AND CONTROL EQUIPMENT [Go to Page]
- Chart 2.26.1.4 Inspection Operation and Hoistway Access Switch Operation Hierarchy
- Chart 2.26.4.1( b) NEC Section 620.3 — Voltage Limitations
- Chart 2.26.4.1( c) NEC Section 620.21( A)( B)( C) — Wiring Methods
- SECTION 2.27 EMERGENCY OPERATION AND SIGNALING DEVICES [Go to Page]
- Chart 2.27.3.2.1( b) Fire Alarm/ Elevator Recall Matrix ( Including Visual Signal)
- Chart 2.27.3.2.1( b) Fire Alarm/ Elevator Recall Matrix ( Including Visual Signal) ( Cont'd)
- SECTION 2.28 LAYOUT DATA
- SECTION 2.29 IDENTIFICATION
- PART 3 HYDRAULIC ELEVATORS [Go to Page]
- SECTION 3.1 CONSTRUCTION OF HOISTWAYS AND HOISTWAY ENCLOSURES
- SECTION 3.4 BOTTOM AND TOP CAR CLEARANCES AND RUNBYS FOR CARS AND COUNTERWEIGHTS
- SECTION 3.6 PROTECTION OF SPACES BELOW HOISTWAY
- SECTION 3.7 MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS
- SECTION 3.11 PROTECTION OF HOISTWAY- LANDING OPENINGS
- SECTION 3.14 CAR ENCLOSURES, CAR DOORS AND GATES, AND CAR ILLUMINATION
- SECTION 3.15 CAR FRAMES AND PLATFORMS
- SECTION 3.16 CAPACITY AND LOADING
- SECTION 3.17 CAR SAFETIES, COUNTERWEIGHT SAFETIES, PLUNGER GRIPPER, AND GOVERNORS [Go to Page]
- Chart 3.17.3.5( a) Plunger Gripper Stopping Distances
- SECTION 3.18 HYDRAULIC JACKS
- SECTION 3.19 VALVES, PRESSURE PIPING, AND FITTINGS
- SECTION 3.21 COUNTERWEIGHTS
- SECTION 3.22 BUFFERS AND BUMPERS
- SECTION 3.23 GUIDE RAILS, GUIDE- RAIL SUPPORTS, AND FASTENINGS
- SECTION 3.24 HYDRAULIC MACHINES AND TANKS
- SECTION 3.25 TERMINAL STOPPING DEVICES
- SECTION 3.26 OPERATING DEVICES AND CONTROL EQUIPMENT
- SECTION 3.27 EMERGENCY OPERATION AND SIGNALING DEVICES
- SECTION 3.28 LAYOUT DATA
- PART 4 ELEVATORS WITH OTHER TYPES OF DRIVING MACHINES [Go to Page]
- SECTION 4.1 RACK- AND- PINION ELEVATORS
- SECTION 4.2 SCREW- COLUMN ELEVATORS
- SECTION 4.3 HAND ELEVATORS
- PART 5 SPECIAL APPLICATION ELEVATORS [Go to Page]
- SECTION 5.1 INCLINED ELEVATORS
- SECTION 5.2 LIMITED- USE/ LIMITED- APPLICATION ELEVATORS
- SECTION 5.3 PRIVATE RESIDENCE ELEVATORS
- SECTION 5.4 PRIVATE RESIDENCE INCLINED ELEVATORS
- SECTION 5.5 POWER SIDEWALK ELEVATORS
- SECTION 5.6 ROOFTOP ELEVATORS
- SECTION 5.7 SPECIAL PURPOSE PERSONNEL ELEVATORS
- SECTION 5.8 MARINE ELEVATORS
- SECTION 5.9 MINE ELEVATORS
- SECTION 5.10 ELEVATORS USED FOR CONSTRUCTION
- PART 6 ESCALATORS AND MOVING WALKS [Go to Page]
- SECTION 6.1 ESCALATORS
- SECTION 6.2 MOVING WALKS
- PART 7 DUMBWAITERS AND MATERIAL LIFTS [Go to Page]
- SCOPE
- SECTION 7.1 POWER AND HAND DUMBWAITERS WITHOUT AUTOMATIC TRANSFER DEVICES [Go to Page]
- Chart 7 The Difference Between a Freight Elevator, B20 Reciprocating Conveyor, Type A Material Lift, Type B Material Lift, and Dumbwaiter
- SECTION 7.2 ELECTRIC AND HAND DUMBWAITERS WITHOUT AUTOMATIC TRANSFER DEVICES
- SECTION 7.3 HYDRAULIC DUMBWAITERS WITHOUT AUTOMATIC TRANSFER DEVICES
- SECTION 7.4 MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES
- SECTION 7.5 ELECTRIC MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES
- SECTION 7.6 HYDRAULIC MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES
- SECTION 7.7 AUTOMATIC TRANSFER DEVICES
- SECTION 7.8 POWER DUMBWAITERS WITH AUTOMATIC TRANSFER DEVICES
- SECTION 7.9 ELECTRIC MATERIAL LIFTS WITH AUTOMATIC TRANSFER DEVICES
- SECTION 7.10 HYDRAULIC MATERIAL LIFTS WITH AUTOMATIC TRANSFER DEVICES
- PART 8 GENERAL REQUIREMENTS [Go to Page]
- SECTION 8.1 SECURITY
- SECTION 8.2 DESIGN DATA AND FORMULAS
- SECTION 8.3 ENGINEERING TESTS, TYPE TEST, AND CERTIFICATION
- SECTION 8.4 ELEVATOR SAFETY REQUIREMENTS FOR SEISMIC RISK ZONE 2 OR GREATER [Go to Page]
- Chart 8.4( a) Earthquake Magnitudes
- Chart 8.4( b) San Fernando Earthquake Damage to Elevator Systems
- SECTION 8.5 ESCALATOR AND MOVING WALK SAFETY REQUIREMENTS FOR SEISMIC RISK ZONE 2 OR GREATER
- SECTION 8.6 MAINTENANCE, REPAIR, REPLACEMENT, AND TESTING
- SECTION 8.7 ALTERATIONS [Go to Page]
- Chart 8.7( a) Pre- Modernization Checklist for Electric Elevators
- SECTION 8.8 WELDING
- SECTION 8.9 CODE DATA PLATE
- SECTION 8.10 ACCEPTANCE INSPECTIONS AND TESTS
- SECTION 8.11 PERIODIC INSPECTIONS AND WITNESSING OF TESTS [Go to Page]
- Chart 8.11.1.3( a) Recommended Inspection and Test Intervals in " Months"
- Chart 8.11.1.3( b) Guidelines on Use of Monitoring to Provide Inspection Data
- 8.12 FLOOD RESISTANCE
- PART 9 REFERENCE CODES, STANDARDS, AND SPECIFICATIONS [Go to Page]
- LOCATING CODES AND STANDARDS
- UNITED STATES CODES AND STANDARDS
- ADA Standards
- ABA Standards
- ADA/ ABA AG Technical Assistance
- NATIONAL STANDARDS SYSTEMS NETWORK
- CANADIAN CODES AND STANDARDS
- ACCREDITED ELEVATOR/ESCALATOR CERTIFICATION
ORGANIZATION (AECO)
- INTERNATIONAL CODES AND STANDARDS
- OUT-OF-PRINT CODES AND STANDARDS
- ADDITIONAL RESOURCE MATERIAL
- NONMANDATORY APPENDICES [Go to Page]
- A CONTROL SYSTEM
- B
DOOR LANDING AND UNLOCKING ZONES
-
C LOCATION OF TOP EMERGENCY EXIT
- D RATED LOAD AND CAPACITY PLATES FOR PASSENGER ELEVATORS
- E CSA B44 ELEVATOR REQUIREMENTS FOR PERSONS WITH PHYSICAL DISABILITIES
- F ASCENDING CAR OVERSPEED AND UNINTENDED CAR MOVEMENT PROTECTION
-
G TOP- OF- CAR CLEARANCE
-
H PRIVATE RESIDENCE ELEVATOR GUARDING
- I ESCALATOR AND MOVING WALK DIAGRAMS
- J RELATIONSHIP OF PIT LADDER TO HOISTWAY DOOR UNLOCKING MEANS
- K BEVELING AND CLEARANCE REQUIREMENTS
- L INDEX OF ALTERATION REQUIREMENTS FOR ELECTRIC ELEVATORS, HYDRAULIC ELEVATORS, ESCALATORS, AND MOVING WALKS
- M INERTIA APPLICATION FOR TYPE A SAFETY DEVICE LOCATION OF TEST WEIGHT
- N RECOMMENDED INSPECTION AND TEST INTERVALS IN " MONTHS"
- O DELETED NONMANDATORY APPENDIX P PLUNGER GRIPPER STOPPING DISTANCES
-
Q EXPLANATORY FIGURES FOR THE DEFINITIONS OF ELEVATOR MACHINERY SPACE, MACHINE ROOM, CONTROL SPACE, CONTROL ROOM, REMOTE MACHINE ROOM, OR REMOTE CONTROL ROOM
- R INSPECTION OPERATION AND HOISTWAY ACCESS SWITCH OPERATION HIERARCHY
- S VERTICALLY SLIDING DOORS — ILLUSTRATIONS OF DETECTION ZONES
-
T INSPECTION AND REPLACEMENT OF STEEL WIRE ROPES
-
U TRACTION ELEVATOR SUSPENSION SYSTEM — DESIGN REQUIREMENTS
- INDEX
- THE AUTHOR
[Go to Page]