ASME B30.22-2023 Articulating Boom Cranes, 2023
- CONTENTS
- FOREWORD
- ASME B30 COMMITTEE ROSTER
- CORRESPONDENCE WITH THE B30 COMMITTEE
- B30 STANDARD INTRODUCTION
- ASME B30.22-2023 SUMMARY OF CHANGES
- Chapter 22-0 Scope, Definitions, Personnel Competence, Translations, and References [Go to Page]
- SECTION 22-0.1: SCOPE OF B30.22
- SECTION 22-0.2: DEFINITIONS [Go to Page]
- 22-0.2.1 Mounting of Articulating Boom Cranes
- 22-0.2.2 General Definitions
- SECTION 22-0.3: LEGEND FOR FIGURES 22-0.3-1 THROUGH 22-0.3-4
- SECTION 22-0.4: NOMENCLATURE FOR ARTICULATING CRANES
- SECTION 22-0.5: PERSONNEL COMPETENCE
- SECTION 22-0.6: TRANSLATIONS [Go to Page]
- 22-0.6.1 Technical and Safety-Related Instructions and Manuals
- 22-0.6.2 Translation of Technical and Safety-Related Information and Manuals
- SECTION 22-0.7: REFERENCES
- Chapter 22-1 Construction and Characteristics [Go to Page]
- SECTION 22-1.1: LOAD RATINGS [Go to Page]
- 22-1.1.1 Load Ratings Where Stability Governs Lifting Performance
- 22-1.1.2 Load Ratings Where Factors Other Than Stability Govern Lifting Performance
- 22-1.1.3 Load Rating Charts
- SECTION 22-1.2: BOOM LIFT, BOOM TELESCOPING, AND LOAD HOIST MECHANISMS [Go to Page]
- 22-1.2.1 Inner, Outer, and Jib Boom Lift Mechanism
- 22-1.2.2 Telescoping Boom(s)
- 22-1.2.3 Load Hoist Mechanism (Load Hoist Equipped Machines Only)
- SECTION 22-1.3: SWING MECHANISM [Go to Page]
- 22-1.3.1 Swing Control
- 22-1.3.2 Swing Braking Means and Locking Devices
- SECTION 22-1.4: CRANE TRANSPORT
- SECTION 22-1.5: ROPES, ROPE-LIFTING COMPONENTS, AND REEVING ACCESSORIES [Go to Page]
- 22-1.5.1 Sheaves
- 22-1.5.2 Load Hooks, Ball Assemblies, and Load Blocks
- SECTION 22-1.6: CONTROLS [Go to Page]
- 22-1.6.1 General
- 22-1.6.2 Control Forces and Movements
- 22-1.6.3 Wireless (Radio) Remote Controls
- SECTION 22-1.7: INSTALLATION [Go to Page]
- 22-1.7.1 Testing
- 22-1.7.2 Exhaust Gases
- SECTION 22-1.8: CONSTRUCTION [Go to Page]
- 22-1.8.1 Welding
- 22-1.8.2 Operational Aids
- 22-1.8.3 Hydraulic and Pneumatic Line Protection
- 22-1.8.4 Lubricating Points
- 22-1.8.5 Stabilizers
- 22-1.8.6 Design Requirements
- 22-1.8.7 Miscellaneous Equipment
- 22-1.8.8 Replacement Parts
- SECTION 22-1.9: OPERATING MANUAL
- Chapter 22-2 Inspection, Testing, and Maintenance [Go to Page]
- SECTION 22-2.1: INSPECTION [Go to Page]
- 22-2.1.1 General
- 22-2.1.2 Inspection Classification
- 22-2.1.3 Frequent Inspection
- 22-2.1.4 Periodic Inspection
- 22-2.1.5 Operational Aids
- 22-2.1.6 Cranes Not in Regular Use
- SECTION 22-2.2: TESTING [Go to Page]
- 22-2.2.1 Operational Tests
- 22-2.2.2 Load Test
- 22-2.2.3 Stability Test
- SECTION 22-2.3: MAINTENANCE [Go to Page]
- 22-2.3.1 Preventive Maintenance
- 22-2.3.2 Maintenance Procedure
- 22-2.3.3 Adjustments, Alterations, and Repairs
- 22-2.3.4 Lubrication
- 22-2.3.5 Ropes
- Chapter 22-3 Operation [Go to Page]
- SECTION 22-3.1: QUALIFICATIONS AND RESPONSIBILITIES [Go to Page]
- 22-3.1.1 Operators
- 22-3.1.2 Qualifications for Operators
- 22-3.1.3 Responsibilities
- SECTION 22-3.2: OPERATING PRACTICES [Go to Page]
- 22-3.2.1 Size of Load
- 22-3.2.2 Operational Aids
- 22-3.2.3 Crane Setup
- 22-3.2.4 Attaching the Load
- 22-3.2.5 Moving the Load
- 22-3.2.6 Stowing/Unstowing Procedure
- 22-3.2.7 Personnel Lifting
- 22-3.2.8 Critical Lifts
- SECTION 22-3.3: SIGNALS [Go to Page]
- 22-3.3.1 General
- 22-3.3.2 Standard Signals
- 22-3.3.3 Signalperson Qualifications
- 22-3.3.4 Standard Hand Signals
- 22-3.3.5 Standard Voice Signals
- 22-3.3.6 Special Signals
- SECTION 22-3.4: OPERATION IN THE VICINITY OF ELECTRIC POWER LINES [Go to Page]
- 22-3.4.1 General
- 22-3.4.2 Operation in the Vicinity of De-Energized and Grounded Electric Power Transmission or Distribution Lines
- 22-3.4.3 Operation in the Vicinity of De-Energized Electric Power Lines Other Than Transmission and Distribution Lines
- 22-3.4.4 Transit or Travel in the Vicinity of Energized Electric Power Lines With No Load and Boom Lowered
- 22-3.4.5 Operation in the Vicinity of Energized Electric Power Lines: Crane Configurations Not Capable of Reaching Within the Specified Clearance
- 22-3.4.6 Operation in the Vicinity of Energized Electric Power Lines: Crane Configurations Capable of Reaching Within the Specified Clearance
- 22-3.4.7 Operation Below Energized Electric Power Lines
- 22-3.4.8 Operation Within the Specified Clearance With the Electric Power Lines Energized
- SECTION 22-3.5: MISCELLANEOUS
- Figures [Go to Page]
- Figure 22-0.2.1-1 Commercial Truck-Mounted With Ground Control
- Figure 22-0.2.1-2 Commercial Truck-Mounted With Top Seat Control
- Figure 22-0.2.1-3 Commercial Truck-Rear-Mounted With Remote Control
- Figure 22-0.2.1-4 Crawler-Mounted
- Figure 22-0.2.1-5 Stationary Installation
- Figure 22-0.2.1-6 Railcar Installation
- Figure 22-0.2.1-7 Trailer-Mounted
- Figure 22-0.2.1-8 Traveling Base-Mounted on Trailer
- Figure 22-0.2.1-9 Off-Road Vehicle
- Figure 22-0.3-1 Definitions of Specifications for Articulating Cranes
- Figure 22-0.3-2 Hook Approach
- Figure 22-0.3-3 Elevation Below Horizontal
- Figure 22-0.3-4 Elevation Above Horizontal
- Figure 22-0.4-1 Nomenclature for Articulating Cranes
- Figure 22-1.1.3-1 Work Areas
- Figure 22-3.3.4-1 Standard Hand Signals
- Figure 22-3.4.1-1 Flowchart to Assist in Determination of the Applicable Subsection for Operation in the Vicinity of Power Lines
- Figure 22-3.4.1-2 Specified Clearance Around an Energized Power Line
- Figure 22-3.4.1-3 Specified Clearance Around an Energized Electric Power Line That Shall Be Maintained When the Crane Is in Travel or Transit
- Figure 22-3.4.1-4 Electric Power Line Support Structures
- Table [Go to Page]
- Table 22-3.4.1-1 Specified Clearance for Operation in the Vicinity of Energized Electric Power Lines [Go to Page]