ASME N511-2022 In-Service Testing of Nuclear Air-Treatment, Heating, Ventilating, and Air-Conditioning Systems, 2022
- CONTENTS
- FOREWORD
- ASME COMMITTEE ROSTER
- CORRESPONDENCE WITH THE COMMITTEE ON NUCLEAR AIR AND GAS TREATMENT
- ASME N511-2022 SUMMARY OF CHANGES
- 1 INTRODUCTION [Go to Page]
- 1.1 Scope
- 1.2 Purpose
- 1.3 Applicability
- 1.4 Use of This Standard
- 1.5 Definitions
- 2 REFERENCES
- 3 GENERAL INSPECTION AND TEST REQUIREMENTS [Go to Page]
- 3.1 Test Instruments
- 3.2 Reference Values
- 3.3 Inspection and Test Requirements
- 4 COMMON TESTS [Go to Page]
- 4.1 Visual Inspection
- 4.2 Pressure Boundary Tests
- 4.3 Vibration Test
- 5 IN-SERVICE TEST REQUIREMENTS [Go to Page]
- 5.1 General
- 5.2 Fan Tests
- 5.3 Damper In-Service Tests
- 5.4 Duct-and-Housing In-Service Tests
- 5.5 Refrigeration Equipment In-Service Tests
- 5.6 Conditioning Equipment In-Service Tests
- 5.7 Moisture Separator, Prefilter, HEPA Filter Bank In-Service Tests
- 5.8 Type II, Type III, and Type IV Adsorber Bank In-Service Tests
- 5.9 Adsorbent In-Service Tests
- 5.10 Integrated System Tests
- 5.11 Air System Flow Balance Verification Test
- 6 ACCEPTANCE CRITERIA [Go to Page]
- 6.1 Visual Inspection
- 6.2 Pressure Boundary Tests
- 6.3 Functional Tests
- 7 TESTING FOLLOWING AN ABNORMAL INCIDENT
- 8 CORRECTIVE ACTION REQUIREMENTS
- 9 QUALITY ASSURANCE [Go to Page]
- 9.1 General
- 9.2 Personnel
- 9.3 Documentation
- Figures [Go to Page]
- Figure D-7-1 Traces of Challenge Gas Concentration for Pulse Test That Demonstrates No Leak and Quick Breakthrough
- Figure D-7-2 Traces of Challenge Gas Concentration for Pulse Test That Demonstrates a Leak and Quick Breakthrough
- Tables [Go to Page]
- Table 3.1-1 Instrument Accuracy Requirements
- Table 3.3.4-1 In-Service Test Intervals
- Table 5.2.1-1 Fan In-Service Tests
- Table 5.3.1-1 Damper In-Service Tests
- Table 5.4.1-1 Duct-and-Housing In-Service Tests
- Table 5.5.1-1 Refrigeration Equipment In-Service Tests
- Table 5.6.1-1 Conditioning Equipment In-Service Tests
- Table 5.7.1-1Moisture Separator, Prefilter, HEPA Filter Bank In-Service Tests
- Table 5.8.1-1 Type II, Type III, and Type IV Adsorber Bank In-Service Tests
- Table C-5.3-1 Performance Parameters and Parameter Design Limits
- Table C-5.3-2 Periodic In-Service Test Programs
- MANDATORY APPENDIX I VISUAL INSPECTION CHECKLIST [Go to Page]
- I-1 GENERAL
- I-2 FAN INSPECTION CHECKLIST
- I-3 DAMPER INSPECTION CHECKLIST
- I-4 DUCT, HOUSING, AND MOUNTING FRAME INSPECTION CHECKLIST
- I-5 REFRIGERATION EQUIPMENT INSPECTION CHECKLIST
- I-6 CONDITIONING EQUIPMENT INSPECTION CHECKLIST
- I-7 MOISTURE SEPARATOR BANK, PREFILTER BANK, AND HEPA FILTER BANK INSPECTION CHECKLIST
- I-8 TYPES II, III, AND IV ADSORBER BANK INSPECTION CHECKLIST
- I-9 ACCEPTANCE CRITERIA
- MANDATORY APPENDIX II DUCT-AND-HOUSING LEAK-TEST PROCEDURE [Go to Page]
- II-1 GENERAL
- II-2 SUMMARY OF METHODS
- II-3 PREREQUISITES
- II-4 TEST EQUIPMENT
- II-5 PROCEDURES
- MANDATORY APPENDIX III HEPA FILTER BANK IN-PLACE LEAK-TEST PROCEDURE [Go to Page]
- III-1 GENERAL
- III-2 SUMMARY OF METHOD
- III-3 PREREQUISITES
- III-4 TEST EQUIPMENT
- III-5 PROCEDURE
- III-6 ACCEPTANCE CRITERIA
- MANDATORY APPENDIX IV ADSORBER BANK IN-PLACE LEAK-TEST PROCEDURE [Go to Page]
- IV-1 GENERAL
- IV-2 SUMMARY OF METHOD
- IV-3 PREREQUISITES
- IV-4 TEST EQUIPMENT
- IV-5 PROCEDURE
- IV-6 ACCEPTANCE CRITERIA
- NONMANDATORY APPENDIX A CORRECTIVE ACTION GUIDANCE
- NONMANDATORY APPENDIX B SELECTION CRITERIA FOR CHALLENGE-GAS SUBSTITUTE
- NONMANDATORY APPENDIX C TEST PROGRAM DEVELOPMENT GUIDANCE [Go to Page]
- C-1 OVERVIEW
- C-2 DEFINITIONS
- C-3 TEST PROGRAM DEVELOPMENT
- C-4 AIR/HYDRONIC SYSTEM BALANCE VERIFICATION GUIDANCE
- C-5 SAMPLE TEST PROGRAM
- C-6 REFERENCES
- NONMANDATORY APPENDIX D ADSORBER BANK IN-PLACE LEAK-TEST PROCEDURE USING PULSE-MODE INJECTION WITH CONTINUOUS MONITORS [Go to Page]
- D-1 GENERAL
- D-2 SUMMARY OF METHOD
- D-3 PREREQUISITES
- D-4 TEST EQUIPMENT
- D-5 PROCEDURE
- D-6 ACCEPTANCE CRITERIA
- D-7 GUIDANCE FOR THE USE OF A MULTICHANNEL DATA RECORDER TO DETERMINE BANK LEAKAGE DURING PULSE TESTING OF AN ADSORBER BANK [Go to Page]