Already a subscriber? ![](/assets/images/login.png)
![](/assets/images/x.png)
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check![](/assets/images/x.png)
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
![](/assets/images/159.gif)
BS EN 12514:2020 Components for supply systems for consuming units with liquid fuels, 2021
- undefined
- 1 Scope
- 2 Normative references
- 3 Terms, definitions, symbols and abbreviated terms [Go to Page]
- 3.1 Terms and definitions [Go to Page]
- 3.1.1 General
- 3.1.2 Components
- 3.1.3 Pipeline
- 3.1.4 Control and safety devices for feed pumps [Go to Page]
- 3.1.4.1 Control devices for feed pumps
- 3.1.4.2 Safety devices for feed pumps
- 3.1.5 Supply systems
- 3.1.6 Pressure related terms
- 3.1.7 Temperature related terms
- 3.1.8 Flow related terms
- 3.1.9 Other terms
- 3.2 Symbols and abbreviated terms
- 4 Characteristics [Go to Page]
- 4.1 General
- 4.2 Reaction to fire
- 4.3 Tightness in case of fire
- 4.4 Crushing strength
- 4.5 Internal pressure strength [Go to Page]
- 4.5.1 Characteristics for pressurised systems [Go to Page]
- 4.5.1.1 General
- 4.5.1.2 Type Testing
- 4.5.1.3 Factory production control
- 4.5.2 Characteristics for negative pressurised systems
- 4.6 External pressure strength
- 4.7 Longitudinal bending strength
- 4.8 Maximum load for admissible deformation
- 4.9 Dimensional Tolerance
- 4.10 Impact resistance
- 4.11 Electrostatic behaviour
- 4.12 Tightness [Go to Page]
- 4.12.1 External tightness [Go to Page]
- 4.12.1.1 General
- 4.12.1.2 Type testing
- 4.12.1.3 Factory production control
- 4.12.2 Internal tightness
- 4.13 Permeability
- 4.14 Effectiveness of safety devices [Go to Page]
- 4.14.1 Control and safety devices for feed pumps [Go to Page]
- 4.14.1.1 General
- 4.14.1.2 Control device
- 4.14.1.3 Safety device
- 4.14.2 Pressure compensating device
- 4.14.3 Anti-siphon safety device [Go to Page]
- 4.14.3.1 General
- 4.14.3.2 Mechanical anti-siphon safety device
- 4.14.3.3 Electro-mechanical anti-siphon safety device
- 4.14.4 Remote acting fire safety valve
- 4.14.5 Safety shut-off device
- 4.15 Release of dangerous substances
- 4.16 Noise level
- 4.17 Durability) [Go to Page]
- 4.17.1 Durability against chemical attack [Go to Page]
- 4.17.1.1 Resistance to liquid fuels
- 4.17.1.2 Material
- 4.17.2 Durability against external corrosion)
- 4.17.3 Durability in case of extended temperatures
- 4.17.4 Durability against ultraviolet light
- 4.17.5 Durability against nominal lifetime operation [Go to Page]
- 4.17.5.1 General
- 4.17.5.2 Fitness-for-use test
- 4.17.6 Resistance to humidity
- 5 Testing, assessment and sampling methods [Go to Page]
- 5.1 General tests [Go to Page]
- 5.1.1 General
- 5.1.2 Visual inspection
- 5.1.3 Dimensional test
- 5.2 Reaction to fire
- 5.3 Tightness in case of fire
- 5.4 Crushing strength [Go to Page]
- 5.4.1 Purpose of chrushing strength test for pipeline connections
- 5.4.2 Test method [Go to Page]
- 5.4.2.1 Procedure
- 5.4.2.2 Test pressure
- 5.4.2.3 Test duration
- 5.5 Internal pressure strength [Go to Page]
- 5.5.1 Pressure test [Go to Page]
- 5.5.1.1 General
- 5.5.1.2 Pressure strength test for metallic material
- 5.5.1.3 Pressure strength test for non-metallic materials
- 5.5.1.4 Dynamic strength test for non-metallic materials
- 5.5.2 Vacuum test [Go to Page]
- 5.5.2.1 Test purpose
- 5.5.2.2 Test procedure
- 5.5.2.3 Test pressure
- 5.5.2.4 Test duration
- 5.6 Testing of external pressure strength (Flood resistance) [Go to Page]
- 5.6.1 Test purpose
- 5.6.2 Test procedure
- 5.6.3 Test pressure
- 5.6.4 Test duration
- 5.7 Longitudinal bending strength
- 5.8 Maximum load for admissible deformation
- 5.9 Dimensional Tolerance
- 5.10 Impact resistance
- 5.11 Electrostatic behaviour
- 5.12 Tightness [Go to Page]
- 5.12.1 General
- 5.12.2 External tightness test [Go to Page]
- 5.12.2.1 Type testing
- 5.12.2.2 Factory production control
- 5.12.2.3 External tightness test of the service tank
- 5.12.2.4 External tightness test of the withdrawal device
- 5.12.3 Internal tightness test [Go to Page]
- 5.12.3.1 Test purpose
- 5.12.3.2 Test procedure
- 5.12.3.3 Test pressure
- 5.12.3.4 Test duration
- 5.13 Permeability test
- 5.14 Effectiveness of safety devices [Go to Page]
- 5.14.1 Control and safety devices for feed pumps [Go to Page]
- 5.14.1.1 General
- 5.14.1.2 Control device
- 5.14.1.3 Safety devices
- 5.14.2 Pressure compensating device [Go to Page]
- 5.14.2.1 Type Testing
- 5.14.2.2 Factory production control
- 5.14.3 Anti-siphon safety device [Go to Page]
- 5.14.3.1 General
- 5.14.3.2 Mechanical anti-siphon safety device
- 5.14.3.3 Electro-mechanical anti-siphon safety device
- 5.14.4 Remote acting fire safety valve [Go to Page]
- 5.14.4.1 General
- 5.14.4.2 Temperature sensing and manual reset test
- 5.14.4.3 Safety shut-off device closing time test
- 5.14.4.4 Fail safe test
- 5.14.5 Safety shut-off device
- 5.15 Release of dangerous substances
- 5.16 Noise level [Go to Page]
- 5.16.1 Test purpose
- 5.16.2 Test procedure
- 5.17 Durability [Go to Page]
- 5.17.1 Durability against chemical attack [Go to Page]
- 5.17.1.1 Resistance to liquid fuels
- 5.17.1.2 Material
- 5.17.2 Durability against external corrosion
- 5.17.3 Durability in case of extended temperatures
- 5.17.4 Durability against ultraviolet light
- 5.17.5 Durability against nominal lifetime operation [Go to Page]
- 5.17.5.1 General
- 5.17.5.2 Fitness-for-use test
- 5.17.6 Resistance to humidity
- 5.18 Additional requirements [Go to Page]
- 5.18.1 Construction requirements
- 5.18.2 Maximum/minimum allowable temperature [Go to Page]
- 5.18.2.1 General maximum/minimum allowable temperature
- 5.18.2.2 Different maximum/minimum allowable temperature
- 5.18.3 Flow resistance [Go to Page]
- 5.18.3.1 General
- 5.18.3.2 Feed pump
- 5.18.3.3 Control and safety device for feed pumps
- 5.18.3.4 Service tank
- 5.18.3.5 Service vessel
- 5.18.3.6 Isolating valve
- 5.18.3.7 Quick-acting valve
- 5.18.3.8 Switch-over valve
- 5.18.3.9 Forced switch-over valve
- 5.18.3.10 Check valve
- 5.18.3.11 Pressure compensating device
- 5.18.3.12 Discharge valve
- 5.18.3.13 Pressure reducer
- 5.18.3.14 Filter
- 5.18.3.15 Meter
- 5.18.3.16 De-aerator
- 5.18.3.17 Anti-siphon safety device
- 5.18.3.18 Insulating device
- 5.18.3.19 Pressure gauge
- 5.18.3.20 Vapour/air separator
- 5.18.3.21 Pressure control path
- 5.18.3.22 Pressure retaining device
- 5.18.3.23 Remote acting fire safety valve
- 5.18.3.24 Pipe
- 5.18.3.25 Pipeline connections
- 5.18.3.26 Combined component
- 5.18.3.27 Withdrawal device
- 5.18.4 Environmental considerations
- 5.18.5 Electrical safety
- 5.18.6 Instruction for installation, operation and maintenance
- 5.19 Functional requirements [Go to Page]
- 5.19.1 Feed pump
- 5.19.2 Service tank [Go to Page]
- 5.19.2.1 Maximum filling height
- 5.19.2.2 Temperature control device
- 5.19.3 Service vessel
- 5.19.4 Isolating valve
- 5.19.5 Quick-acting valve
- 5.19.6 Switch-over valve
- 5.19.7 Forced switch-over valve
- 5.19.8 Check valve
- 5.19.9 Discharge valve [Go to Page]
- 5.19.9.1 General
- 5.19.9.2 Type testing
- 5.19.9.3 Factory production control
- 5.19.9.4 Adjustable discharge valve
- 5.19.10 Pressure reducer [Go to Page]
- 5.19.10.1 Design requirements for pressure reducers
- 5.19.10.2 Functional tests
- 5.19.11 Filter [Go to Page]
- 5.19.11.1 General
- 5.19.11.2 Filter for single-pipe system with return flow
- 5.19.11.3 Filter for two-pipe systems
- 5.19.11.4 Filter element
- 5.19.12 Meter
- 5.19.13 De-aerator [Go to Page]
- 5.19.13.1 General
- 5.19.13.2 Differential pressure
- 5.19.13.3 Manual venting device
- 5.19.13.4 Venting capacity
- 5.19.14 Insulating device
- 5.19.15 Pressure gauge
- 5.19.16 Vapour/air separator
- 5.19.17 Pressure control path
- 5.19.18 Pressure retaining device [Go to Page]
- 5.19.18.1 Type testing
- 5.19.18.2 Factory production control
- 5.19.19 Pipe [Go to Page]
- 5.19.19.1 General
- 5.19.19.2 Rigid metallic pipe
- 5.19.19.3 Non-metallic pipe
- 5.19.19.4 Hose
- 5.19.20 Type testing for pipeline connections [Go to Page]
- 5.19.20.1 Repeated assembly test
- 5.19.20.2 Over tightening test
- 5.19.20.3 Vibration test
- 5.19.20.4 Testing for axial tensile strength
- 5.19.21 Combined component
- 5.19.22 Withdrawal device
- 6 Assessment and verification of constancy of performance (AVCP) [Go to Page]
- 6.1 General
- 6.2 Type testing [Go to Page]
- 6.2.1 General
- 6.2.2 Test samples, testing and compliance criteria
- 6.2.3 Test reports
- 6.2.4 Shared other party results
- 6.2.5 Cascading determination of the product type results
- 6.3 Factory production control (FPC) [Go to Page]
- 6.3.1 General
- 6.3.2 Requirements [Go to Page]
- 6.3.2.1 General
- 6.3.2.2 Equipment
- 6.3.2.3 Raw materials and components
- 6.3.2.4 Traceability and marking
- 6.3.2.5 Controls during manufacturing process
- 6.3.2.6 Product testing and evaluation
- 6.3.2.7 Non-complying products
- 6.3.2.8 Corrective action
- 6.3.2.9 Handling, storage and packaging
- 6.3.3 Product specific requirements
- 6.3.4 Initial inspection of factory and of FPC
- 6.3.5 Procedure for modifications
- 6.3.6 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity
- 7 Marking, labelling and packaging [Go to Page]
- 7.1 General
- 7.2 Marking
- 7.3 Packaging
- 8 Additional and functional requirements [Go to Page]
- 8.1 Additional requirements [Go to Page]
- 8.1.1 Construction requirements
- 8.1.2 Maximum/minimum allowable temperature [Go to Page]
- 8.1.2.1 General maximum/minimum allowable temperature
- 8.1.2.2 Different maximum/minimum allowable temperature
- 8.1.3 Flow resistance [Go to Page]
- 8.1.3.1 General
- 8.1.3.2 Feed pump
- 8.1.3.3 Control and safety device for feed pumps
- 8.1.3.4 Service tank
- 8.1.3.5 Service vessel
- 8.1.3.6 Isolating valve
- 8.1.3.7 Quick-acting valve
- 8.1.3.8 Switch-over valve
- 8.1.3.9 Forced switch-over valve
- 8.1.3.10 Check valve
- 8.1.3.11 Pressure compensating device
- 8.1.3.12 Discharge valve
- 8.1.3.13 Pressure reducer
- 8.1.3.14 Filter
- 8.1.3.15 Meter
- 8.1.3.16 De-aerator
- 8.1.3.17 Anti-siphon safety device
- 8.1.3.18 Insulating device
- 8.1.3.19 Pressure gauge
- 8.1.3.20 Vapour/air separator
- 8.1.3.21 Pressure control path
- 8.1.3.22 Pressure retaining device
- 8.1.3.23 Remote acting fire safety valve
- 8.1.3.24 Pipe
- 8.1.3.25 Pipeline connections
- 8.1.3.26 Combined component
- 8.1.3.27 Withdrawal device
- 8.1.4 Environmental considerations
- 8.1.5 Electrical safety
- 8.1.6 Instruction for installation, operation and maintenance
- 8.2 Functional requirements [Go to Page]
- 8.2.1 Feed pump [Go to Page]
- 8.2.1.1 Requirements
- 8.2.1.2 Machine safety requirements and/or protective measures
- 8.2.2 Service tank [Go to Page]
- 8.2.2.1 Maximum filling height
- 8.2.2.2 Temperature control device
- 8.2.2.3 Service tank for intermediate storage
- 8.2.3 Service vessel
- 8.2.4 Isolating valve
- 8.2.5 Quick-acting valve
- 8.2.6 Switch-over valve
- 8.2.7 Forced switch-over valve
- 8.2.8 Check valve
- 8.2.9 Discharge valve [Go to Page]
- 8.2.9.1 General
- 8.2.9.2 Type testing
- 8.2.9.3 Factory production control
- 8.2.10 Pressure reducer [Go to Page]
- 8.2.10.1 Design requirements for pressure reducers
- 8.2.10.2 Functional and constructional characteristics of pressure reducers
- 8.2.10.3 Tests
- 8.2.11 Filter [Go to Page]
- 8.2.11.1 General
- 8.2.11.2 Filter for single-pipe system with return flow
- 8.2.11.3 Filter for two-pipe system
- 8.2.11.4 Filter element
- 8.2.12 Meter [Go to Page]
- 8.2.12.1 General
- 8.2.12.2 Meters for recording the supply
- 8.2.13 De-aerator [Go to Page]
- 8.2.13.1 General
- 8.2.13.2 Differential pressure
- 8.2.13.3 Manual venting device
- 8.2.13.4 Venting capacity
- 8.2.14 Insulating device
- 8.2.15 Pressure gauge
- 8.2.16 Vapour/air separator
- 8.2.17 Pressure control path
- 8.2.18 Pressure retaining device
- 8.2.19 Pipe [Go to Page]
- 8.2.19.1 General
- 8.2.19.2 Rigid metallic pipe
- 8.2.19.3 Non-metallic pipe
- 8.2.19.4 Hose
- 8.2.20 Pipeline connections [Go to Page]
- 8.2.20.1 General
- 8.2.20.2 Types of pipeline connections
- 8.2.20.3 Type testing
- 8.2.21 Combined component
- 8.2.22 Withdrawal device
- Annex A (informative)National technical documents for liquid fuels [Go to Page]
- A.1 General
- A.2 Category A: Liquid fuels derived from petroleum refining processes
- A.3 Category B: Liquid fuels from renewable resources
- A.4 Category C: Combinations of category A and B
- Annex B (normative)Metallic materials for components and parts
- Annex C (normative)Instructions for installation, operation and maintenance [Go to Page]
- C.1 General
- C.2 Contents
- Annex D (informative)Examples for the installation of the components in supply systems
- Annex E (informative)Environmental aspects
- Annex F (informative)Environmental checklist
- Annex G (informative)Vocabulary
- Annex H (normative)Machine safety requirements and/or protective measures [Go to Page]
- H.1 General
- H.2 List of significant hazards
- H.3 Safety requirements and /or protective measures [Go to Page]
- H.3.1 General
- H.3.2 Mechanical safety, stability and control devices
- Annex I (normative)Rigid metallic pipes within the scope of EN 12514 [Go to Page]
- I.1 Rigid metallic pipes for above ground installations [Go to Page]
- I.1.1 General
- I.1.2 Rigid metallic pipes from non-alloy and alloy steels
- I.1.3 Pipes from stainless austenitic steels
- I.1.4 Copper and copper alloy pipes
- I.1.5 Aluminium pipes
- I.2 Rigid metallic pipes for underground installations
- Annex J (informative)Union nut G 3/8 with 60° internal cone as pipeline connection
- Annex K (informative)Stud connectors with sealing ring [Go to Page]
- K.1 General
- K.2 Stud end of stud connector
- K.3 Sealing ring [Go to Page]
- K.3.1 Dimensions and designation
- K.3.2 Materials
- Annex L (informative)Compression fittings for components with G 3/8 internal thread [Go to Page]
- L.1 General
- L.2 Materials
- L.3 Design types [Go to Page]
- L.3.1 Design type G
- L.3.2 Design type A
- L.3.3 Design type O
- Annex M (informative)Stud connectors with o-ring [Go to Page]
- M.1 General
- M.2 Port
- M.3 O-Ring
- M.4 Material
- Annex ZA Annex ZA (informative)Relationship between this European Standard and the essential requirements of EU Directive 2014/32/EU [Go to Page]