BS EN 14825:2016 Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance, 2016
- Contents Page
- European foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms, definitions, symbols, abbreviated terms and units [Go to Page]
- 3.1 Terms and definitions
- 3.2 Symbols, abbreviated terms and units
- Table 1 — Symbols, abbreviated terms and units
- 4 Part load conditions in cooling mode [Go to Page]
- 4.1 General
- 4.2 Air-to-air units
- Table 2 — Part load conditions for air-to-air units [Go to Page]
- 4.3 Water-to-air units and brine-to-air units
- Table 3 — Part load conditions for water-to-air and brine-to-air units [Go to Page]
- 4.4 Air-to-water units
- Table 4 — Part load conditions for air-to-water units [Go to Page]
- 4.5 Water-to-water and brine-to-water units
- Table 5 — Part load conditions for water-to-water units and brine-to-water units
- 5 Part load conditions in heating mode [Go to Page]
- 5.1 General
- 5.2 Air-to-air units
- Table 6 — Part load conditions for air-to-air units for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.3 Water-to-air and brine-to-air units
- Table 7 — Part load conditions for water/brine-to-air units for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.4 Air-to-water units [Go to Page]
- 5.4.1 General
- 5.4.2 Low temperature application
- Table 8 — Part load conditions for air-to-water units in low temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.4.3 Intermediate temperature application
- Table 9 — Part load conditions for air-to-water units in intermediate temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.4.4 Medium temperature application
- Table 10 — Part load conditions for air-to-water units in medium temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.4.5 High temperature application
- Table 11 — Part load conditions for air-to-water units in high temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.5 Water-to-water and brine-to-water units [Go to Page]
- 5.5.1 General
- 5.5.2 Low temperature application
- Table 12 — Part load conditions for water/brine-to-water units in low temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.5.3 Intermediate temperature application
- Table 13 — Part load conditions for water/brine-to-water units in intermediate temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.5.4 Medium temperature application
- Table 14 — Part load conditions for water/brine-to-water units in medium temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder [Go to Page]
- 5.5.5 High temperature application
- Table 15 — Part load conditions for water/brine-to-water units in high temperature application for the reference heating seasons “A” = average, “W” = warmer and “C” = colder
- 6 Calculation methods for SEER and SEERon [Go to Page]
- 6.1 General formula for calculation of SEER
- 6.2 Calculation of the reference annual cooling demand QC
- 6.3 Calculation of the reference annual electricity consumption QCE
- 6.4 Calculation of SEERon
- 6.5 Calculation procedure for determination of EERbin values at part load conditions B, C, D [Go to Page]
- 6.5.1 General
- 6.5.2 Calculation procedure for fixed capacity units [Go to Page]
- 6.5.2.1 Air-to-air and water-to-air units
- 6.5.2.2 Air-to-water, water-to-water and brine-to-water units
- 6.5.3 Calculation procedure for staged and variable capacity units [Go to Page]
- 6.5.3.1 Air-to-air and water-to-air units
- 6.5.3.2 Air-to-water, water-to-water and brine-to-water units
- 7 Calculation methods for seasonal space heating efficiency ηs, SCOP, SCOPon and SCOPnet [Go to Page]
- 7.1 Calculation of the seasonal space heating efficiency ηs
- 7.2 General formula for calculation of SCOP
- 7.3 Calculation of the reference annual heating demand QH
- 7.4 Calculation of the annual electricity consumption QHE
- 7.5 Calculation of SCOPon and SCOPnet
- 7.6 Calculation procedure for determination of COPbin values at part load conditions A to G [Go to Page]
- 7.6.1 General
- 7.6.2 Air-to-air, brine-to-air and water-to-air units [Go to Page]
- 7.6.2.1 Calculation procedure for fixed capacity units
- 7.6.2.2 Calculation procedure for staged and variable capacity units
- 7.6.3 Air-to-water, water-to-water and brine-to-water units [Go to Page]
- 7.6.3.1 Calculation procedure for fixed capacity units
- 7.6.3.2 Calculation procedure for staged and variable capacity units
- 8 Test methods for testing capacities, EERbin and COPbin values during active mode at part load conditions [Go to Page]
- 8.1 General
- 8.2 Basic principles
- Figure 1 — Example of test apparatus for variable airflow [Go to Page]
- 8.3 Uncertainties of measurement
- 8.4 Test procedures for units with fixed capacity [Go to Page]
- 8.4.1 General
- 8.4.2 Air-to-air and water-to-air units – Determination of the degradation coefficients Cdc and Cdh [Go to Page]
- 8.4.2.1 General
- 8.4.2.2 Air-to-air units – Cooling mode
- 8.4.2.3 Air-to-air units – Heating mode
- 8.4.2.4 Water/brine-to-air units – Cooling mode
- 8.4.2.5 Water-to-air units – Heating mode
- 8.4.3 Air-to-water units and water-to-water units – Determination of the degradation factors Cdc and Cdh
- 8.5 Test procedure for staged and variable capacity units [Go to Page]
- 8.5.1 Settings for the required capacity ratio
- 8.5.2 Compensation method
- 9 Test methods for electric power input during thermostat-off mode, standby mode and crankcase heater mode and off mode [Go to Page]
- 9.1 Measurement of electric power consumption during thermostat-off mode
- 9.2 Measurement of the electric power consumption during standby mode
- 9.3 Measurement of the electric power consumption during crankcase heater mode
- 9.4 Measurement of the electric power consumption during off mode
- 10 Test report
- 11 Technical data sheet
- Annex A (normative) Applicable climate bin hours and hours for active mode, thermostat-off, standby, off mode and crankcase heater mode for air conditioners below and equal to 12 kW
- A.1 Climate bins
- A.1.1 Bin limit temperature
- A.1.2 Cooling
- Table A.1 — Bin number j, outdoor temperature Tj in C and number of hours per bin hj corresponding to the reference cooling season
- A.1.3 Heating
- Table A.2 — Bin number j, outdoor temperature Tj in C and number of hours per bin hj corresponding to the reference heating seasons “warmer”, “average”, “colder”
- A.2 Hours for active mode, thermostat-off, standby, off mode
- A.2.1 Cooling
- Table A.3 — Number of hours used for calculation of SEER
- A.2.2 Heating
- Table A.4 — Number of hours used for calculation of SCOP
- A.3 Hours used for crankcase heater mode
- A.3.1 Cooling
- Table A.5 — Crankcase heater mode hours for determination of SEER
- A.3.2 Heating
- Table A.6 — Crankcase heater mode hours for determination of SCOP
- Annex B (normative) Applicable climate bin hours and hours for active, thermostat-off, standby, off and crankcase heater modes for space heaters, air to water and water/brine to water units, below or equal to 400kW
- B.1 Climate bins
- B.1.1 Bin limit temperature
- B.1.2 Heating
- Table B.1 — Bin number j, outdoor temperature Tj in C and number of hours per bin hj corresponding to the reference heating seasons “warmer”, “average”, “colder”
- B.2 Hours for active, thermostat off, standby and off modes - Heating
- Table B.2 — Number of hours used for calculation of SCOP
- B.3 Hours used for crankcase heater mode - Heating
- Table B.3 — Crankcase heater mode hours for determination of SCOP
- Annex C (normative) Template for technical data sheet
- C.1 For air to air units below and equal to 12 kW
- Table C.1 — Technical data sheet template for air to air units below and equal to 12 kW
- C.2 For space heaters, air-to-water and water/brine-to-water units below or equal to 400kW
- Table C.2 — Technical data sheet template for space heaters, air-to-water and water/brine-to-water units below or equal to 400kW
- Annex D (informative) Adaption of water temperature for fixed capacity units
- Figure D.1 — Fixed capacity heat pump
- Figure D.2 — Variable capacity heat pump below its minimum capacity
- Annex E (informative) Calculation example for SEERon and SEER – Application to a reversible air-to-air unit with variable capacity
- E.1 Calculation of SEERon
- Table E.1 — Data for SEER
- Table E.2 — Calculation BIN for SEERon
- E.2 Calculation of SEER
- E.2.1 Calculation of reference annual cooling demand (QC) according to Formula (2)
- E.2.2 Calculation of SEER according to Formula (1)
- Annex F (informative) Calculation example for SCOPon and SCOPnet - Application to a fixed capacity air-to-water heat pump used for floor heating
- Table F.1 — Data for SCOP
- Figure F.1 — Schematic overview of the SCOPon calculation points
- Table F.2 — Calculation Bin for SCOPon
- Table F.3 — Calculation Bin for SCOPnet
- Annex G (informative) Calculation example for SCOPon and SCOPnet – Application to a fixed capacity brine-to-water heat pump used for medium temperature application
- Table G.1 — Data for SCOP
- Figure G.1 — Schematic overview of the SCOPon calculation points
- Table G.2 — Calculation Bin for SCOPon
- Table G.3 — Calculation Bin for SCOPnet
- Annex H (informative) Compensation methods for air-to-water and water/brine-to-water units
- H.1 General
- H.2 Compensation system for reduced capacity test in cooling mode
- Figure H.1 — Test installation for part load testing cooling
- H.3 Compensation system for reduced capacity test in heating mode
- Figure H.2 — Test installation for part load testing heating
- Annex ZA (informative) Relationship between this European Standard and the requirements of Commission Regulation (EU) No 206/2012
- Table ZA.1 — Correspondence between this European Standard and Commission Regulation (EU) No 206/2012
- Annex ZB (informative) Relationship between this European Standard and the requirements of Commission Regulation (EU) No 813/2013 and Commission Delegated Regulation (EU) No 811/2013
- Table ZB.1 — Correspondence between this European Standard and Commission Regulation (EU) No 813/2013
- Once this standard is cited in the Official Journal of the European Union under that Commission Regulation, compliance with the clauses of this standard given in Table ZB.2 confers, within the limits of the scope of this standard, a presumption of con...
- Table ZB.2 — Correspondence between this European Standard and Commission Delegated Regulation (EU) No 811/2013
- Bibliography [Go to Page]