Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS EN ISO 12807:2021 Safe transport of radioactive materials. Leakage testing on packages, 2021
- undefined
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbols and units
- 5 Regulatory requirements
- 5.1 Relevant regulations
- 5.2 Regulatory containment requirements
- 6 Procedure for meeting the requirements of this document
- 6.1 General
- 6.2 Quality management system
- 6.3 Procedure
- 6.3.1 General
- 6.3.2 Determination of permissible activity release rates
- 6.3.3 Determination of standardized leakage rates
- 6.3.4 Determination of permissible test leakage rates for each verification stage
- 6.3.5 Selection of appropriate test methods
- 6.3.6 Performance of test and record of results
- 7 Determination of permissible activity release rates
- 7.1 Step 1: List the radioactive contents, Ai
- 7.2 Step 2: Determine the total releasable activity, RIT
- 7.3 Step 3: Determine the maximum permissible activity release rates, R
- 8 Determination of standardized leakage rates
- 8.1 General
- 8.2 Step 4: Determine the activity release rate due to permeation, RP
- 8.3 Step 5: Determine the maximum permissible activity release rate due to leakage, RG
- 8.4 Step 6: Determine the activity per unit volume of the containment system medium, C
- 8.5 Step 7: Determine the maximum permissible volumetric leakage rate of the medium, L
- 8.6 Step 8: Determine the maximum permissible equivalent capillary leak diameter, D
- 8.7 Step 9: Determine the permissible standardized leakage rate, QSLR
- 9 Containment-system verification requirements
- 9.1 Containment-system verification stages
- 9.1.1 General
- 9.1.2 Design verification
- 9.1.3 Fabrication verification
- 9.1.4 Preshipment verification
- 9.1.5 Periodic verification
- 9.1.6 Maintenance verification
- 9.2 Verification requirements
- 9.2.1 General
- 9.2.2 Step 10: Determine permissible test leakage rate for each verification stage, QTDA, QTDN, QTF, QTS, QTP and QTM
- 9.2.3 Step 11: Select appropriate test methods
- 10 Leakage test procedure requirements
- 10.1 General
- 10.2 Step 12: Perform tests and record results
- 10.3 Test sensitivity
- 10.4 Test procedure requirements
- 10.4.1 General
- 10.4.2 Testing
- Annex A (informative) Preferred leakage test methods
- Annex B (informative) Methods of calculation
- Annex C (informative) Conversion tables
- Annex D (informative) Worked examples
- Annex E (informative) Rationale
- Bibliography [Go to Page]