Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices (Published), 2020
- ANSI C63.10-2020 Front Cover
- Title page
- Important Notices and Disclaimers Concerning IEEE Standards Documents
- Participants
- Introduction
- Contents
- 1. Overview [Go to Page]
- 1.1 Scope
- 1.2 Purpose and applications
- 1.3 Stating requirements and recommendations
- 1.4 Measurement uncertainty
- 1.5 Dimensional tolerances
- 2. Normative references
- 3. Definitions, acronyms, and abbreviations [Go to Page]
- 3.1 Definitions
- 3.2 Acronyms and abbreviations
- 4. Measurement instrumentation [Go to Page]
- 4.1 Emission measuring instrumentation
- 4.2 Line impedance stabilization network
- 4.3 Antennas
- 4.4 Calibration of measuring equipment
- 5. General measurement and setup considerations [Go to Page]
- 5.1 General requirements
- 5.2 Radiated emission test site
- 5.3 Radiated emission test distance
- 5.4 Measurements around the EUT
- 5.5 Frequency range of radiated emission measurements
- 5.6 Number of fundamental frequencies to be tested in EUT transmit band
- 5.7 Swept-frequency device measurements
- 5.8 EUT antenna requirements
- 5.9 Restricted frequency bands of operation
- 5.10 General unlicensed wireless device configurations and test setups
- 5.11 Operational requirements during testing
- 5.12 Applied modulation
- 5.13 Variations in supply voltage
- 5.14 Special accessories
- 6. Standard test methods [Go to Page]
- 6.1 General
- 6.2 Standard test method for ac power-line conducted emissions from unlicensed wireless devices
- 6.3 Radiated emissions testing-common requirements
- 6.4 Radiated emissions from unlicensed wireless devices below 30 MHz
- 6.5 Radiated emissions from unlicensed wireless devices in the frequency range of 30 MHz to 1000 MHz
- 6.6 Radiated emissions from unlicensed wireless devices from 1 GHz to 40 GHz
- 6.7 Antenna-port conducted emission measurements
- 6.8 Frequency stability tests
- 6.9 Occupied bandwidth tests
- 6.10 Band-edge testing
- 6.11 On-site (in situ) radiated emission measurements
- 6.12 Figures for Clause 6
- 7. Additional tests and requirements for specific devices [Go to Page]
- 7.1 Test method for determining compliance of cordless telephone handset security code
- 7.2 Frequency pairing of cordless phones
- 7.3 Input power to final RF stage for certain types of unlicensed wireless devices
- 7.4 Procedure for determining compliance of unlicensed wireless devices having periodic operation
- 7.5 Procedure for determining the average value of pulsed emissions
- 7.6 Evaluation of certain unlicensed wireless devices with periodic emissions against limits
- 7.7 Procedure for determining compliance of inductive-loop devices
- 7.8 Evaluation of frequency-hopping device parameters
- 8. Procedures for determining emissions from FM transmitters designed for use in vehicles [Go to Page]
- 8.1 General
- 8.2 Wireless transmission between FM source and vehicle antenna
- 8.3 Injection into a vehicle’s wiring system via the CLA socket
- 8.4 In situ measurement procedure for vehicles
- 8.5 Conducted power measurement
- 8.6 Capacitive coupling to a vehicle FM antenna
- 8.7 Procedure for determining occupied bandwidth of FM transmitter
- 8.8 Figures for Clause 8
- 9. Procedures for testing millimeter-wave systems [Go to Page]
- 9.1 Instrument and test sites
- 9.2 Equations
- 9.3 Emission bandwidth - relative measurement procedure
- 9.4 Occupied bandwidth—Power bandwidth (99%) measurement procedure
- 9.5 Frequency stability measurement procedure
- 9.6 Exploratory radiated measurements
- 9.7 Maximizing procedure for measurements
- 9.8 Measurement of the fundamental emission using spectrum analyzer
- 9.9 Measurement of the fundamental emission using an RF detector
- 9.10 Measurement of unwanted emissions above 40 GHz
- 9.11 Measurement of unwanted emissions at or below 40 GHz
- 10. Procedures for measuring ultra-wideband devices [Go to Page]
- 10.1 Evaluation of −10 dB bandwidth
- 10.2 Radiated measurement procedure below 960 MHz
- 10.3 Radiated measurement procedure above 960 MHz
- 11. Procedures for testing DTS devices [Go to Page]
- 11.1 General
- 11.2 Power limits, definitions, and device configuration
- 11.3 Acceptable measurement configurations
- 11.4 Test suite considerations
- 11.5 Reference level/attenuation/headroom
- 11.6 Duty cycle (D), transmission duration (T), and maximum power control level
- 11.7 Transmit antenna performance considerations
- 11.8 DTS bandwidth
- 11.9 Fundamental emission output power
- 11.10 Maximum power spectral density level in the fundamental emission
- 11.11 Emissions in non-restricted frequency bands
- 11.12 Emissions in restricted frequency bands
- 12. Testing of Unlicensed National Information Infrastructure (U-NII) devices [Go to Page]
- 12.1 General considerations
- 12.2 Duty cycle (D), transmission duration (T), and maximum power control level
- 12.3 Addressing wide band signal measurement issues
- 12.4 Maximum conducted output power
- 12.5 Emission bandwidth and occupied bandwidth
- 12.6 Peak power spectral density
- 12.7 Unwanted emissions measurement
- 12.8 Elevation mask procedures
- 13. Procedures for measuring device operating using antenna arrays with beam-steering and/or beamforming capability [Go to Page]
- 13.1 Definitions specific to this clause
- 13.2 Baseline scan methodologies
- 13.3 Final tests
- 13.4 Occupied bandwidth, power density, output power, and band-edge tests
- 13.5 Spurious emissions tests
- 14. Procedures for combining emissions and computing directional gain from devices with multiple outputs [Go to Page]
- 14.1 Scope
- 14.2 Purpose
- 14.3 Limitations
- 14.4 Methodologies for combining emissions from multiple outputs
- 14.5 Guidance for combining emissions from multiple outputs of a transmitter of from multiple transmitters
- 14.6 Directional gain calculations
- 14.7 MIMO with cross-polarized antenna
- 14.8 Transmitters with non-detachable antennas for MIMO operation
- 15. Whitespace device testing [Go to Page]
- 15.1 Test configuration requirements
- 15.2 Permissible channels of operation
- 15.3 Fixed TVBDs Power measurements
- 15.4 Personal/Portable TVBDs
- 15.5 Band-edge measurement
- 15.6 Adjacent-channel measurement
- 16. Procedures for measuring devices equipped with wireless power transfer functionality [Go to Page]
- 16.1 Definitions specific to Clause 16
- 16.2 Scope
- 16.3 Test procedures
- 17. Test reports
- Annex A (informative) Cross-references between regulatory requirements and ANSI C63.10 test methods
- Annex B (informative) Example test report contents
- Annex C (informative) Pulse desensitization considerations for emission measurements using a spectrum analyzer or EMI receiver (Schaefer [B69])
- Annex D (informative) Detector functions
- Annex E (informative) Measurements above 1 GHz-instrumentation perspective
- Annex F (informative) Broadband measurement discussion
- Annex G (informative) Basic relationships among field strength, power, effective radiated power, and equivalent isotropically radiated power
- Annex H (informative) Rationale for making radiated emission measurements using two different methods
- Annex I (informative) Site considerations for measuring inductive-loop devices in the near-field
- Annex J (informative) Developing a transfer function for FM transmitters (alternative procedure for determining compliance of unlicensed FM transmitters)
- Annex K (informative) Discussion on Dynamic Frequency Selection (DFS) for Operation in the 5250 MHz to 5350 MHz and 5470 MHz to 5725 MHz bands
- Annex L (informative) Desensitization factor and sweep time considerations for measurements of FMCW signals
- Annex M (informative) Glossary
- Annex N (informative) Bibliography
- Back Cover [Go to Page]