NFPA 30: Flammable & Combustible Liquids Code, 1996
- Chapter 1 General Provisions [Go to Page]
- 1-1 Scope.
- 1-2 * Purpose.
- 1-3 Applicability.
- 1-4 Equivalency.
- 1-5 Retroactivity.
- 1-6 Definitions.
- 1-7 Definition and Classification of Liquids.
- 1-8 Use of Other Units.
- 1-9 General Requirements.
- Chapter 2 Tank Storage [Go to Page]
- 2-1 Scope.
- 2-2 Design and Construction of Tanks.
- 2-3 Installation of Outside Aboveground Tanks.
- 2-4 Installation of Underground Tanks.
- 2-5 * Storage Tank Buildings.
- 2-6 Supports, Foundations, and Anchorage for All Tank Locations.
- 2-7 * Sources of Ignition.
- 2-8 Testing and Maintenance.
- 2-9 Fire Protection and Identification.
- 2-10 Prevention of Overfilling of Tanks.
- 2-11 * Leakage Detection and Inventory Records for Underground Tanks.
- Chapter 3 Piping Systems [Go to Page]
- 3-1 Scope.
- 3-2 General.
- 3-3 Materials for Piping, Valves, and Fittings.
- 3-4 Pipe Joints.
- 3-5 Supports.
- 3-6 * Protection against Corrosion.
- 3-7 Underground Piping.
- 3-8 Valves.
- 3-9 Testing.
- 3-10 * Identification.
- Chapter 4 Container and Portable Tank Storage [Go to Page]
- 4-1 General.
- 4-2 Design, Construction, and Capacity of Containers.
- 4-3 Design, Construction, and Capacity of Storage Cabinets.
- 4-4 * Design, Construction, and Operation of Inside Liquid Storage Areas.
- 4-5 Requirements for Liquid Storage Areas in Other Occupancies.
- 4-6 * Hazardous Materials Storage Lockers.
- 4-7 Outdoor Storage.
- 4-8 Fire Protection and Control.
- Chapter 5 Operations [Go to Page]
- 5-1 Scope.
- 5-2 General.
- 5-3 Facility Design.
- 5-4 Reserved.
- 5-5 Incidental Operations.
- 5-6 Loading and Unloading Operations.
- 5-7 Wharves.
- 5-8 Reserved.
- 5-9 Control of Ignition Sources.
- 5-10 Vapor Recovery and Vapor Processing Systems.
- 5-11 Management of Fire Hazards.
- 5-12 Fire Protection and Fire Suppression.
- Chapter 6 Referenced Publications [Go to Page]
- 6-1 The following documents or portions thereof are referenced within this code and shall be con...
- Appendix A Explanatory Material
- Appendix B Emergency Relief Venting for Fire Exposure for Aboveground Tanks
- Appendix C Temporarily Out of Service, Closure in Place, or Closure by Removal of Underground Tanks
- Appendix D Development of Fire Protection Criteria Shown in Section 4-8 and Suggested Fire Prote...
- Appendix E Suggested Fire Protection for Containers of Flammable and Combustible Liquids
- Appendix F Fugitive Emissions Calculations
- Appendix G Referenced Publications [Go to Page]