FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-A760 2010ASTM A760 / A760M - 10Standard Specification for Corrugated Steel Pipe, Metallic-Coated for Sewers and DrainsActive Standard ASTM A760 / A760M | Developed by Subcommittee: A05.17 Book of Standards Volume: 01.06 ASTM A760 / A760MAbstract This specification covers the standard requirements for corrugated, metallic-coated steel pipes intended for use in sewers, storm water drainage, underdrains, culverts construction, and similar other uses. These pipes are not normally used for the conveyance of sanitary or industrial wastes. This specification however does not include requirements for bedding, backfill, or the relationship between earth cover load and sheet thickness of the pipe. The steel sheet used for the pipes, coupling bands, and steel inserts shall be formed from zinc-coated sheet, aluminum-coated sheet, aluminum-zinc alloy-coated sheet, zinc-aluminum-mischmetal alloy-coated sheet, or zinc and aramid fiber composite coated sheet. The rivets used in riveted pipes shall be of the same material as the base metal specified for the corrugated sheets and shall be thoroughly galvanized or sherardized. Bolts, nuts, and other threaded items used with joining systems shall be zinc coated by hot dip processing, electroplating, or mechanical processing. The pipes shall be fabricated in full circular cross section with either annular or helical corrugations while the seams shall be spot welded in such a manner that they will develop the full strength of the pipe and not affect the shape or nominal diameter of the pipe. A rational analysis or a suitable physical test shall be performed to determine the specified structural properties of the joining systems such as shear, moment, and tensile strengths. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. 1. Scope 1.1 This specification covers corrugated steel pipe intended for use for storm water drainage, underdrains, the construction of culverts, and similar uses. Pipe covered by this specification is not normally used for the conveyance of sanitary or industrial wastes. The steel sheet used in fabrication of the pipe has a protective metallic coating of zinc (galvanizing), aluminum, 55 % aluminum-zinc alloy, or zinc-5 % aluminum-mischmetal alloy. 1.1.1 Steel sheet with zinc and aramid fiber composite coating may be specified for fabrication of pipe. Pipe made from sheet with this composite coating is always furnished with an asphalt coating. Therefore, the requirements in this specification should be considered as applying to a semifinished pipe; the finished pipe must include provisions of Specification A849 . Note 1Pipe fabricated with zinc and aramid fiber composite coated sheet and asphalt post coating may be used for sanitary sewers and industrial applications. Petroleum products or similar materials in the sewer effluent may affect the performance of the asphalt coating.
ASTM Standards A90/A90M Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings A153/A153M Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware A307 Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile Strength A428/A428M Test Method for Weight [Mass] of Coating on Aluminum-Coated Iron or Steel Articles A449 Specification for Hex Cap Screws, Bolts and Studs, Steel, Heat Treated, 120/105/90 ksi Minimum Tensile Strength, General Use A563 Specification for Carbon and Alloy Steel Nuts A563M Specification for Carbon and Alloy Steel Nuts (Metric) A742/A742M Specification for Steel Sheet, Metallic Coated and Polymer Precoated for Corrugated Steel Pipe A762/A762M Specification for Corrugated Steel Pipe, Polymer Precoated for Sewers and Drains A780 Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings A796/A796M Practice for Structural Design of Corrugated Steel Pipe, Pipe-Arches, and Arches for Storm and Sanitary Sewers and Other Buried Applications A798/A798M Practice for Installing Factory-Made Corrugated Steel Pipe for Sewers and Other Applications A849 Specification for Post-Applied Coatings, Pavings, and Linings for Corrugated Steel Sewer and Drainage Pipe A885/A885M Specification for Steel Sheet, Zinc and Aramid Fiber Composite Coated for Corrugated Steel Sewer, Culvert, and Underdrain Pipe A929/A929M Specification for Steel Sheet, Metallic-Coated by the Hot-Dip Process for Corrugated Steel Pipe B633 Specification for Electrodeposited Coatings of Zinc on Iron and Steel B695 Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel C1619 Specification for Elastomeric Seals for Joining Concrete Structures D1056 Specification for Flexible Cellular Materials--Sponge or Expanded Rubber F568M Specification for Carbon and Alloy Steel Externally Threaded Metric Fasteners (Metric) AASHTO Standards T249 Test for Helical Lock Seam Corrugated PipeKeywords corrugated steel pipe; drainage pipe; hydrostatic testing; leak resistant joints; metallic coated pipe; qualification testing; sewer pipe; water tight joints; Metallic-coated steel pipe--specifications; Sewer pipe (steel)--specifications; Structural steel (SS) pipe--specifications; Corrugated steel sewer/drain pipe--specifications; Zinc-coated steel pipe--specifications; ICS Code ICS Number Code 23.040.10 (Iron and steel pipes) DOI: 10.1520/A0760_A0760M-10 ASTM International is a member of CrossRef. ASTM A760 / A760MThe following editions for this book are also available...
This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |