ASTM C1214-02
Historical Standard: ASTM C1214-02 Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
SUPERSEDED (see Active link, below)
ASTM C1214
1. Scope
1.1 This test method covers procedures for testing concrete pipe sewerlines, when using the negative air pressure (vacuum) test method to demonstrate the integrity of the installed material and the construction procedures. This test method covers testing of 4 to 36-in. diameter circular concrete pipe sewerlines utilizing gasketed joints.
Note 1The user of this test method is advised that methods described herein may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery or backfill. Minimum test times presented in are for pipelines. Holding times for testing an individual pipe may have to be increased to allow for the accumulation of leakage when the tested pipe are incorporated into a continuous pipeline.
1.2 A complete metric companion to Test Method C 1214 has been developedC 1214M; therefore, no metric equivalents are presented in this test method.
Note 2The user of this test method is advised that the negative air pressure (vacuum) test criteria presented in this test method are similar to those in general use. The test and criteria have been used widely and successfully in testing smaller diameter pipe. Larger pipe will be accepted more conveniently by visual inspection and individual joint testing.
Note 3The user of this test method is advised that no correlation has been found between loss of vacuum and water leakage.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety precautions.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C822 Terminology Relating to Concrete Pipe and Related Products
C924 Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method
C969 Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
Keywords
Concrete pipe; Density--concrete; Negative air pressure (vacuum) method; Portland cement; Pressure testing--concrete pipe; Sewerlines; Silica;
ICS Code
ICS Number Code 23.040.50 (Pipes and fittings of other materials)
DOI: 10.1520/C1214-02
ASTM International is a member of CrossRef.