FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-C1672 2007ASTM C1672 - 07Standard Test Method for Determination of Uranium or Plutonium Isotopic Composition or Concentration by the Total Evaporation Method Using a Thermal Ionization Mass SpectrometerActive Standard ASTM C1672 | Developed by Subcommittee: C26.05 Book of Standards Volume: 12.01
Translated Standard: Russian ASTM C16721. Scope 1.1 This method describes the determination of the isotopic composition and/or the concentration of uranium and plutonium as nitrate solutions by the thermal ionization mass spectrometric (TIMS) total evaporation method. Purified uranium or plutonium nitrate solutions are loaded onto a degassed metal filament and placed in the mass spectrometer. Under computer control, ion currents are generated by heating of the filament(s). The ion beams are continually measured until the sample is exhausted. The measured ion currents are integrated over the course of the run, and normalized to a reference isotope ion current to yield isotopic ratios. 1.2 In principle, the total evaporation method should yield isotopic ratios that do not require mass bias correction. In practice, some samples may require this bias correction. When compared to the conventional TIMS method, the total evaporation method is approximately two times faster, improves precision from two to four fold, and utilizes smaller sample sizes. 1.3 The total evaporation method may lead to biases in minor isotope ratios due to peak tailing from adjacent major isotopes, depending on sample characteristics. The use of an electron multiplier equipped with an energy filter may eliminate or diminish peak tailing effects. Measurement of instrument abundance sensitivity may be used to ensure that such biases are negligible, or may be used to bias correct minor isotope ratios. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards C753 Specification for Nuclear-Grade, Sinterable Uranium Dioxide Powder C757 Specification for Nuclear-Grade Plutonium Dioxide Powder, Sinterable C776 Specification for Sintered Uranium Dioxide Pellets C787 Specification for Uranium Hexafluoride for Enrichment C833 Specification for Sintered (Uranium-Plutonium) Dioxide Pellets C967 Specification for Uranium Ore Concentrate C996 Specification for Uranium Hexafluoride Enriched to Less Than 5 % 235U C1008 Specification for Sintered (Uranium-Plutonium) Dioxide Pellets--Fast Reactor Fuel C1068 Guide for Qualification of Measurement Methods by a Laboratory Within the Nuclear Industry C1156 Guide for Establishing Calibration for a Measurement Method Used to Analyze Nuclear Fuel Cycle Materials C1168 Practice for Preparation and Dissolution of Plutonium Materials for Analysis C1347 Practice for Preparation and Dissolution of Uranium Materials for Analysis C1411 Practice for The Ion Exchange Separation of Uranium and Plutonium Prior to Isotopic Analysis C1415 Test Method for 238Pu Isotopic Abundance By Alpha Spectrometry D3084 Practice for Alpha-Particle Spectrometry of Water E137 Practice for Evaluation of Mass Spectrometers for Quantitative Analysis from a Batch Inlet Keywords atom percent; isotope dilution mass spectrometry; isotopic composition; mass fractionation; plutonium; thermal ionization mass spectrometry; total evaporation; uranium; weight percent; ICS Code ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology) DOI: 10.1520/C1672-07 ASTM International is a member of CrossRef. ASTM C1672The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|