ASTM C302-95(2001)e1
Historical Standard: ASTM C302-95(2001)e1 Standard Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation
SUPERSEDED (see Active link, below)
ASTM C302
1. Scope
1.1 This test method covers the determination of the dimensions and density, after conditioning, of preformed pipe insulation.
1.1.1 Procedure 1 is applicable to sections of one-piece pipe covering or to sections of segmental pipe covering that can be joined together concentrically and measured as one-piece.
1.1.2 Procedure 2 is applicable to segmental pipe covering where each section of material is measured.
1.1.3 Procedure 3 is applicable to sections of one-piece pipe covering, such as soft foam or mineral wool materials, where it is possible to penetrate the material.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C167 Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations
C168 Terminology Relating to Thermal Insulation
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
C870 Practice for Conditioning of Thermal Insulating Materials
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
Keywords
pipe insulation density; pipe insulation dimensions; thermal insulation;
ICS Code
ICS Number Code 27.220 (Heat recovery. Thermal insulation)
DOI: 10.1520/C0302-95R01E01