Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94394)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6631)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    C799-99(2005) Standard Test Methods for Chemical, Mass Spectrometric, Spectrochemical, Nuclear, and Radiochemical Analysis of Nuclear-Grade Uranyl Nitrate Solutions
    Edition: 2005
    $113.57
    Unlimited Users per year

Description of ASTM-C799 2005

ASTM C799-99-Reapproved2005

Historical Standard: Standard Test Methods for Chemical, Mass Spectrometric, Spectrochemical, Nuclear, and Radiochemical Analysis of Nuclear-Grade Uranyl Nitrate Solutions




ASTM C799

Scope

1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solution to determine compliance with specifications.

1.2 The analytical procedures appear in the following order:

Sections
Determination of Uranium 7
Specific Gravity by Pycnometry 15-20
Free Acid by Oxalate Complexation 21-27
Determination of Thorium 28
Determination of Chromium 29
Determination of Molybdenum 30
Halogens Separation by Steam Distillation 31-35
Fluoride by Specific Ion Electrode 36-42
Halogen Distillate Analysis: Chloride, Bromide, and Iodide by
Amperometric Microtitrimetry
43
Determination of Chloride and Bromide 44
Determination of Sulfur by X-Ray Fluorescence 45
Sulfate Sulfur by (Photometric) Turbidimetry 46
Phosphorus by the Molybdenum Blue (Photometric) Method 54-61
Silicon by the Molybdenum Blue (Photometric) Method 62-69
Carbon by Persulfate Oxidation-Acid Titrimetry 70
Conversion to U3O8 71-74
Boron by Emission Spectrography 75-81
Impurity Elements by Spark Source Mass Spectrography 82
Isotopic Composition by Thermal Ionization Mass Spectrometry 83
Uranium-232 by Alpha Spectrometry 84-90
Total Alpha Activity by Direct Alpha Counting 91-97
Fission Product Activity by Beta Counting 98-104
Entrained Organic Matter by Infrared Spectrophotometry 105
Fission Product Activity by Gamma Counting 106
Determination of Arsenic 107
Determination of Impurities for the EBC Calculation 108
Determination of Technetium 99 109
Determination of Plutonium and Neptunium 110

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 5.

7.1 Uranium can be determined using iron (II) reduction and dichromate titration. Test Method C1267 can be used.

7.2 Uranium can also be determined using cerium (IV) oxidation titrimetry. ISO 7097 Test Method can be used.

7.3 Uranium can also be determined by X-Ray Fluorescence using Test Method C1254.

7.4 Previous sections have been deleted.

8.1 This test method covers the determination of uranium in nuclear-grade uranyl nitrate solution. Appropriate size sample aliquots are chosen to obtain 5 to 10 g of U3O8.

15.1 This test method covers the determination of the specific gravity of a solution of uranyl nitrate to ±0.0004.

21.1 This test method covers the determination of the free acid content of uranyl nitrate solutions that may contain a ratio of up to 5 moles of acid to 1 mole of uranium.

28.1 The determination of thorium by the arsenazo (III) (photometric) method has been discontinued, (see C799-93).

28.2 As an alternative, thorium can be determined using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). See Test Method C1287.

28.3 Previous sections have been deleted.

29.1 The determination of chromium by the diphenyl carbazide method has been discontinued, (see C799-93).

29.2 As an alternative, chromium can be determined using inductively coupled plasma atomic emission spectrometry (ICP-AES). Test Method C761 can be used providing a transformation to U3O8 so described hereafter in sections 117–120 A direct conversion to the amonium fluoride plus nitric acid solution can also be used, (see C761).

29.3 As an alternative, chromium can be determined using atomic absorption spectroscopy. Test Method C761 can be used.

29.4 As an alternative, chromium can be determined using ICP-MS. Test Method C1287 can be used.

29.5 Previous sections have been deleted.

30.1 The determination of molybdenum by the thiocyanate (photometric) method has been discontinued, (See C799-93).

30.2 As an alternative, molybdenum can be determined using ICP-MS. Test Method C1287 can be used.

30.3 As an alternative, molybdenum can be determined using ICP-AES. Test Method C761, sections 251 to 271 can be used providing a tranformation to U3O8 as described hereafter in sections 71-74. A direct conversion to the amonium fluoride plus nitric acid solution can also be used, (see C761, section 251).

30.4 Previous sections have been deleted.

31.1 This test method covers the separation of the halogens by means of a steam distillation.

36.1 This test method covers the determination of as low as 2 μg F/g U in distillate containing all the halogens.

43.1 The determination of chloride, bromide and iodide by microtitrimetric method has been discontinued, (see C799-93).

43.2 Previous sections have been deleted.

44.1 Determination of bromide by the fluorescein (photometric) method has been discontinued, (see C799-93).

44.2 As an alternative, bromide and chloride can be determined by X-Ray Fluorescence. Halogens are precipitated by silver nitrate and filtrated. The precipitate is washed and counted by X-Ray Fluorescence.

44.3 Previous sections have been deleted.

45.1 Sulfur can be determined using X-Ray Fluorescence. See Test Method C1296.

46.1 This test method covers the determination of the sulfur concentration, which exists as sulfate in uranyl nitrate solutions, in the range from 100 to 1000 μg S/g of uranium.

54.1 This test method covers determination of phosphorus in nuclear-grade uranyl nitrate solutions. Appropriate dilution may be made to facilitate obtaining samples containing 0 to 60 μg P.

62.1 This test method covers the determination of up to 20 μg Si (2 to 200 μg Si/g U) in uranyl nitrate solutions.

70.1 Determination of carbon by the persulfate oxidation titrimetry method has been discontinued, (see C799-93).

70.2 Previous sections have been deleted.

71.1 This test method is specifically designed for the conversion of uranyl nitrate to U3O8.

75.1 This test method covers the determination of 0.05 to 33 μg B/g of uranium.

82.1 The determination of impurities by spark source mass spectrography method has been discontinued, (see C799-93).

82.2 Previous section have been deleted.

83.1 The determination of isotopic composition using a single collector thermal ionisation mass spectrometer has been discontinued, (see C799-93 and C696).

83.2 As an alternative, the isotopic composition can be measured using a multi- collector thermal ionisation spectrometer. Test Method C1413 can be used.

83.3 As an alternative, the isotopic composition can be measured using isotope dilution mass spectormetry. Test Method C1380 can be used.

83.4 Previous section have been deleted.

84.1 This test method covers the determination of uranium-232 in nuclear-grade uranyl nitrate solutions, in concentrations as low as 0.05 ng 232U/ 235U.

91.1 This test method covers the determination of the sum of all alpha-emitting nuclides in uranyl nitrate solutions.

98.1 This test method covers the measurement of the beta emitters fission product activity of nuclear-grade uranyl nitrate solutions.

105.1 The determination of entrained organic matter by infrared spectrophotometry method has been discontinued, (see C799-93).

106.1 The determination of gamma emiters fission products can be done with Test Method C1295.

107.1 The determination of arsenic can be done with atomic absorption. Test Method C1219 can be used.

107.2 As an alternative, arsenic can be determined using ICP-MS. Test Method C1287 can be used.

108.1 The determination of impurities for the Equivalent Boron Content can be done with ICP-MS. Test Method C1287 can be used. The EBC table described in C1233 can be used.

109.1 The determination of Technetium 99 can be done using ICP-MS. Test Method C1287 can be used.

109.2 As an alternative, Technetium can be determined after solvent extraction by beta counting. Test Method C761 can be used.

110.1 Plutonium can be determined by alpha counting after ion exchange. Test Method C761 can be used.

110.2 As an alternative, plutonium can be determined by alpha counting after solvent extraction. Test Method C761 can be used.

110.3 Neptunium can be determined by alpha counting after solvent extraction. Test Method C761 can be used.

110.4 Previous sections have been deleted.


Keywords

impurity content; isotopic composition; stoichiometry; uranium content; uranyl nitrate


ICS Code

ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)


DOI: 10.1520/C0799-99R05

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,152.58 Buy
VAR
ASTM
[+] $1,737.94 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X