ASTM C900-01
Historical Standard: ASTM C900-01 Standard Test Method for Pullout Strength of Hardened Concrete
SUPERSEDED (see Active link, below)
ASTM C900
1. Scope
1.1 This test method covers determination of the pullout strength of hardened concrete by measuring the force required to pull an embedded metal insert and the attached concrete fragment from a concrete test specimen or structure. The insert is either cast into the fresh concrete or installed in hardened concrete.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information purposes only.
1.3 The text of this test method references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this test method.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
E4 Practices for Force Verification of Testing Machines
E74 Practice of Calibration of Force-Measuring Instruments for Verifying the Force Indication of Testing Machines
Keywords
concrete strength; in-place strength; in-place testing; pullout test;
ICS Code
ICS Number Code 91.100.30 (Concrete and concrete products)
DOI: 10.1520/C0900-01
ASTM International is a member of CrossRef.