ASTM D2275-95
Historical Standard: ASTM D2275-95 Standard Test Method for Voltage Endurance of Solid Electrical Insulating Materials Subjected to Partial Discharges (Corona) on the Surface
SUPERSEDED (see Active link, below)
ASTM D2275
1. Scope
1.1 This test method differentiates among solid electrical insulating materials for use at commercial power frequencies with respect to their voltage endurance under the action of corona (see Note 1). In general, this test method is more meaningful for rating materials with respect to their resistance to prolonged a-c stress under corona conditions than is dielectric strength.
Note 1--The term 'corona' is used almost exclusively in this test method instead of 'partial discharge', because it is a visible glow at the edge of the smaller electrode. This is a difference in location, not in kind. Partial discharges also occur at the edges of electrodes, and in general corona describes an electrical discharge irrespective of its location.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
D1711 Terminology Relating to Electrical Insulation
D1868 Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems
D5032 Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions
D6054 Practice for Conditioning Electrical Insulating Materials for Testing
E41 Terminology Relating To Conditioning
E104 Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions
E171 Practice for Conditioning and Testing Flexible Barrier Packaging
Institute of Electrical and Electronic Engineers (IEEE) Document
IEEE SS 11205-TBR Guide for the Statistical Analysis of Electrical Insulation Voltage Endurance Data, 1987 Available from Institute of Electrical and Electronics Engineers, Inc. (IEEE), 445 Hoes Ln., P.O. Box 1331, Piscataway, NJ 08854-1331, http://www.ieee.org.International Electrotechnical Commission (IEC) Documents
IEC Publication 6034 Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.Special Technical Publications
Corona Measurement a ASTM, 1979.Keywords
partial discharge; surface discharge; threshold voltage; voltage indurance; voltage stress time curve; volt time curve; Corona; Electrical insulating solids; Electrical properties; Surface discharges (corona); Voltage;
ICS Code
ICS Number Code 29.035.01 (Insulating materials in general)
DOI: 10.1520/D2275-95
ASTM International is a member of CrossRef.