FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-D4012 2009ASTM D4012 - 81(2009)Standard Test Method for Adenosine Triphosphate (ATP) Content of Microorganisms in WaterActive Standard ASTM D4012 | Developed by Subcommittee: D19.24 Book of Standards Volume: 11.02 ASTM D4012Significance and Use A rapid and routine procedure for determining biomass of the living microorganisms in cultures, waters, wastewaters, and in plankton and periphyton samples taken from surface waters is frequently of vital importance. However, classical techniques such as direct microscope counts, turbidity, organic chemical analyses, cell tagging, and plate counts are expensive, time-consuming, or tend to underestimate total numbers. In addition, some of these methods do not distinguish between living and nonliving cells. The ATP firefly (luciferin-luciferase) method is a rapid, sensitive determination of viable microbial biomass. ATP is the primary energy donor for life processes, does not exist in association with nonliving detrital material, and the amount of ATP per unit of biomass (expressed in weight) is relatively constant. (ATP per cell varies with species and physiological state of the organism.) This test method can be used to: Estimate viable microbial biomass in cultures, waters, and wastewaters. Estimate the amount of total viable biomass in plankton and periphyton samples. Estimate the number of viable cells in a unispecies culture if the ATP content (or if the average amount of ATP) per cell is known. Estimate and differentiate between zooplanktonic, phytoplanktonic, bacterial, and fungal ATP through size fractionation of water, and wastewater samples. Measure the mortality rate of microorganisms in toxicity tests in entrainment studies, and in other situations where populations or assemblages of microorganisms are placed under stress. 1. Scope 1.1 This test method covers the measurement of adenosine triphosphate (ATP) in microorganisms in concentrations normally found in laboratory cultures, waters, wastewaters, and in plankton and periphyton samples from waters. 1.2 Knowledge of the concentration of ATP can be related to viable biomass or metabolic activity, or by utilizing an average concentration (or amount) of ATP per cell, an estimated count of microorganisms can be obtained in the case of unispecies cultures. 1.3 This test method offers a high degree of sensitivity, rapidity, accuracy, and reproducibility. However, extreme care must be taken at each step in the analysis to ensure meaningful and reliable results. 1.4 The analyst should be aware that the precision statement pertains only to determinations in reagent water and not necessarily in the matrix being tested. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards D1129 Terminology Relating to Water D1193 Specification for Reagent Water Keywords Adenosine triphosphate (ATP) content; ATP firefly method; Biomass; Filters/filter procedures--water testing; Microorganisms; Optical materials/properties/tests--water; Organic compounds--water; Pathogens--water; Photoluminescence; Sludge; Toxicity/toxicology--water environments; Wastewater testing/treatment; Waterborne sediment; ICS Code ICS Number Code 13.060.50 (Examination of water for chemical substances) DOI: 10.1520/D4012-81R09 ASTM International is a member of CrossRef. ASTM D4012This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|