FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-D5850 2012ASTM D5850 - 95(2012)Standard Test Method for (Analytical Procedure) Determining Transmissivity, Storage Coefficient, and Anisotropy Ratio from a Network of Partially Penetrating WellsActive Standard ASTM D5850 | Developed by Subcommittee: D18.21 Book of Standards Volume: 04.08 ASTM D5850Significance and Use 5.1 This test method is one of several available for determining vertical anisotropy ratio. Among other available methods are Weeks ( ( 5 ) ; see Test Method D5473 ), that relies on distance-drawdown data, and Way and McKee ( 6 ) , that utilizes time-drawdown data. An important restriction of the Weeks distance-drawdown method is that the observation wells must have identical construction (screened intervals) and two or more of the observation wells must be located at a distance from the pumped well beyond the effects of partial penetration. The procedure described in this test method general distance-drawdown method, in that it works in theory for any observation well configuration incorporating three or more wells, provided some of the wells are within the zone where flow is affected by partial penetration. 5.2 Assumptions: 5.2.1 Control well discharges at a constant rate, Q . 5.2.2 Control well is of infinitesimal diameter and partially penetrates the aquifer. 5.2.3 Data are obtained from a number of partially penetrating observation wells, some screened at elevations similar to that in the pumped well and some screened at different elevations. 5.2.4 The aquifer is confined, homogeneous and areally extensive. The aquifer may be anisotropic, and, if so, the directions of maximum and minimum hydraulic conductivity are horizontal and vertical, respectively. 5.2.5 Discharge from the well is derived exclusively from storage in the aquifer. 5.3 Calculation Requirements Application of this method is computationally intensive. The function, f s , shown in ( Eq 4 ) must be evaluated numerous times using arbitrary input parameters. It is not practical to use existing, somewhat limited, tables of values for f s and, because this equation is rather formidable, it is not readily tractable by hand. Because of this, it is assumed the practitioner using this test method will have available a computerized procedure for evaluating the function f s . This can be accomplished using commercially available mathematical software including some spreadsheet applications, or by writing programs in languages such as Fortran or C. 1. Scope 1.1 This test method covers an analytical procedure for determining the transmissivity, storage coefficient, and ratio of vertical to horizontal hydraulic conductivity of a confined aquifer using observation well drawdown measurements from a constant-rate pumping test. This test method uses data from a minimum of four partially penetrating, properly positioned observation wells around a partially penetrating control well. 1.2 The analytical procedure is used in conjunction with the field procedure in Test Method D4050 . 1.3 Limitations The limitations of the technique for determination of the horizontal and vertical hydraulic conductivity of aquifers are primarily related to the correspondence between the field situation and the simplifying assumption of this test method. 1.4 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards D653 Terminology Relating to Soil, Rock, and Contained Fluids D4050 Test Method for (Field Procedure) for Withdrawal and Injection Well Tests for Determining Hydraulic Properties of Aquifer Systems D5473 Test Method for (Analytical Procedure for) Analyzing the Effects of Partial Penetration of Control Well and Determining the Horizontal and Vertical Hydraulic Conductivity in a Nonleaky Confined Aquifer Keywords anisotropy; aquifers; aquifer tests; control wells; groundwater; hydraulic conductivity; observation well; storage coefficient; transmissivity; ICS Code ICS Number Code 13.060.10 (Water of natural resources); 73.100.30 (Equipment for drilling and mine excavation) DOI: 10.1520/D5850-95R12 ASTM International is a member of CrossRef. ASTM D5850This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|