Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(343)
(623)
(599)
(55)
(234)
(1019)
(696)
(2187)
(117)
(95582)
(63)
(590)
(124)
(33)
(24)
(20)
(96542)
(17)
(1)
(374)
(325)
(7302)
(241)
(21)
(7)
(1669)
(18)
(19)
(28)
(4)
 
(6)
(7)
(115)
(1)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(28)
(27)
(30)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    D7032-15 Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite and Plastic Lumber Deck Boards, Stair Treads, Guards, and Handrails
    Edition: 2015
    $144.00
    Unlimited Users per year

Description of ASTM-D7032 2015

ASTM D7032-15

Historical Standard: Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite and Plastic Lumber Deck Boards, Stair Treads, Guards, and Handrails




ASTM D7032

Scope

1.1 This specification covers the procedures to establish a performance rating for wood-plastic composite (WPC) deck boards. This specification also defines the procedures to establish a performance rating for WPC guards and handrails. The purpose of this specification is to establish the basis for code recognition of these products or systems in exterior applications where combustible construction is allowed (see X1.1).

Note 1: While WPCs may contain wood fiber, the presence of wood fiber in the composite is not required by this standard. Other lignocellulosic materials may be used. For WPC deck boards and guardrail systems evaluated according to this standard, the structural, physical, and fire attributes may or may not exhibit similarity to those of wood due to the presence, type, and quantity of plastic(s) in the composite. WPCs should not be assumed to behave similarly to wood. For example, to address the influence of plastic in the composite, special considerations in the standard address sensitivity to temperature, ultraviolet (UV) exposure, and freeze-thaw resistance.

1.1.1 The plastic component of wood-plastic composites and plastic lumber covered by this specification shall consist primarily of thermoplastics.

1.2 Deck boards, stair treads, guards, and handrails covered by this specification are permitted to be of any code compliant shape and thickness (solid or non-solid).

1.3 A deck board, and a deck board used as a stair tread, are assigned a span rating indicating its ability to comply with model code specified functions identified for its specific end use. A guard or handrail is recognized for its ability to meet minimum code requirements specified in the appropriate model building code.

1.4 Wood-plastic composites and plastic lumber are produced in a broad range of fiber and/or resin formulations. It is recognized that the performance requirements in this specification are valid for any material or combination of materials used as deck boards, stair treads, guards, or handrails.

1.5 Details of manufacturing processes are beyond the scope of this specification.

1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

1.8 Table of Contents:

 

Section

Scope

1

Referenced Documents

2

Terminology

3

General Requirements

4

 Sampling

4.1

 Sample Size

4.2

 Conditioning

4.3

 Flexural Tests

4.4

 Temperature and Moisture Effects

4.5

 Ultraviolet (UV) Resistance Test

4.6

 Freeze-Thaw Resistance Test

4.7

 Biodeterioration Tests

4.8

 Fire Performance Tests

4.9

Deck Board Performance Requirements

5

 General

5.1

 Flexural Performance Tests

5.2

 Determination of the Unadjusted Allowable Load

5.3

 Creep-Recovery Test

5.4

 Mechanical Fastener Holding Tests

5.5

 Slip Resistance Test

5.6

Guard and Handrail Performance Requirements

6

 General

6.1

 Guardrail System Test Requirements

6.2

  One- and Two-Family Dwelling Requirements

6.2.1.1

 Handrail Test Requirements (Concentrated Load)

6.3

Report

7

Independent Inspection

8

Manufacturing Standard

9

Precision and Bias

10

Keywords

11

Two-Span Test Method

Annex A1

Commentary

Appendix X1


Keywords

adjustment factor; deck board; guard; handrail; independent inspection; manufacturing standard; span rating; stair tread; wood-plastic composite;


ICS Code

ICS Number Code 79.080 (Semi-manufactures of timber)


DOI: 10.1520/D7032-15



X
01 02 03 04 05 06 07 08 09 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48 49 50
51 52 53 54 55 56 57 58 59 60
61 62 63 64 65 66 67 68 69 70
71 72 73 74 75 76 77 78 79 80
81 82 83 84 85 86 87 88 89 90
91 92 93 94 95 96 97 98 99 100