ASTM D7103-06
Historical Standard: ASTM D7103-06 Standard Guide for Assessment of Medical Gloves
SUPERSEDED (see Active link, below)
ASTM D7103
1. Scope
1.1 This guide is intended to assist in the identification and application of the most appropriate ASTM and associated standards for the assessment, development of specifications, and selection of medical gloves with the ultimate goal of maintaining the safety and health of healthcare workers who may come into contact with biological and chemical hazards.
1.2 No guidance document or assessment protocol can ensure the selection of medical gloves that guarantees healthcare worker protection. The purpose of testing and assessing medical gloves is to generate the performance data and quality information that will allow the most appropriate assessment and selection of medical gloves. Ultimately, the selection of medical gloves shall be based on the evaluation of available technical data, quality information, and professional assessment of risk.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D412 Test Methods for Vulcanized Rubber and Thermoplastic Elastomers--Tension
D573 Test Method for Rubber--Deterioration in an Air Oven
D3577 Specification for Rubber Surgical Gloves
D3578 Specification for Rubber Examination Gloves
D3767 Practice for Rubber--Measurement of Dimensions
D5151 Test Method for Detection of Holes in Medical Gloves
D5250 Specification for Poly(vinyl chloride) Gloves for Medical Application
D5712 Test Method for Analysis of Aqueous Extractable Protein in Natural Rubber and Its Products Using the Modified Lowry Method
D6124 Test Method for Residual Powder on Medical Gloves
D6319 Specification for Nitrile Examination Gloves for Medical Application
D6499 Test Method for The Immunological Measurement of Antigenic Protein in Natural Rubber and its Products
D6977 Specification for Polychloroprene Examination Gloves for Medical Application
F739 Test Method for Permeation of Liquids and Gases through Protective Clothing Materials under Conditions of Continuous Contact
F1342 Test Method for Protective Clothing Material Resistance to Puncture
F1383 Test Method for Permeation of Liquids and Gases through Protective Clothing Materials under Conditions of Intermittent Contact
F1671 Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System
American National Standards Institute/American Dental Association (ANSI/ADA) Standards
Acceptance Program G Infection Control Products Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036. Specification No. 10 Non-Sterile Nitrile Gloves for Dentistry Specification No. 10 Non-Sterile Poly(vinyl chloride) Gloves for Dentistry Specification No. 76 Non-Sterile Natural Rubber Latex Gloves for DentistryInternational Standards Organization (ISO) Standard
ISO 2859 Sampling Procedures and Tables for Inspection by AttributesNational Fire Protection Association (NFPA) Standard
NFPA 1999 Standard on Protective Clothing for Emergency Medical Operations Available from National Fire Protection Association (NFPA), 1 Batterymarch Park, Quincy, MA 02269-9101.Keywords
assessment; barrier properties; latex; medical gloves; natural rubber latex; nitrile; performance; physical properties; polychloroprene; quality; selection; vinyl;
ICS Code
ICS Number Code 11.140 (Hospital equipment)