FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-D7664 2018ASTM D7664-10-e1-Reapproved2018Active Standard: Standard Test Methods for Measurement of Hydraulic Conductivity of Unsaturated SoilsASTM D7664Scope 1.1 These test methods cover the quantitative measurement of data points suitable for defining the hydraulic conductivity functions (HCF) of unsaturated soils. The HCF is defined as either the relationship between hydraulic conductivity and matric suction or that between hydraulic conductivity and volumetric water content, gravimetric water content, or the degree of saturation. Darcy’s law provides the basis for measurement of points on the HCF, in which the hydraulic conductivity of a soil specimen is equal to the coefficient of proportionality between the flow rate of water through the specimen and the hydraulic gradient across the specimen. To define a point on the HCF, a hydraulic gradient is applied across a soil specimen, the corresponding transient or steady-state water flow rate is measured (or vice versa), and the hydraulic conductivity calculated using Darcy’s law is paired with independent measurements of matric suction or volumetric water content in the soil specimen. 1.2 These test methods describe a family of test methods that can be used to define points on the HCF for different types of soils. Unfortunately, there is no single test that can be applied to all soils to measure the HCF due to testing times and the need for stress control. It is the responsibility of the requestor of a test to select the method that is most suitable for a given soil type. Guidance is provided in the significance and use section of these test methods. 1.3 Similar to the Soil Water Retention Curve (SWRC), defined as the relationship between volumetric water content and matric suction, the HCF may not be a unique function. Both the SWRC and HCF may follow different paths whether the unsaturated soil is being wetted or dried. A test method should be selected which replicates the flow process occurring in the field. 1.4 These test methods describe three categories of methods (Categories A through C) for direct measurement of the HCF. Category A (column tests) involves methods used to define the HCF using measured one-dimensional profiles of volumetric water content or suction with height in a column of soil compacted into a rigid wall permeameter during imposed transient and steady-state water flow processes. Different means of imposing water flow processes are described in separate methods within Category A. Category B (axis translation tests) involves methods used to define the HCF using outflow measurements from a soil specimen underlain by a saturated high-air entry porous disc in a permeameter during imposed transient water flow processes. The uses of rigid-wall or flexible-wall permeameters are described in separate methods within Category B. Category C (centrifuge permeameter test) includes a method to define the HCF using measured volumetric water content or suction profiles in a column of soil confined in a centrifuge permeameter during imposed steady-state water flow processes. The methods in this standard can be used to measure hydraulic conductivity values ranging from the saturated hydraulic conductivity of the soil to approximately 10-11 m/s. 1.5 The methods of data analysis described in these test methods involve measurement of the water flow rate and hydraulic gradient, and calculation of the hydraulic conductivity using Darcy’s law (direct methods) (1).2 Alternatively, inverse methods may also be used to define the HCF (2). These employ an iterative, regression-based approach to estimate the hydraulic conductivity that a soil specimen would need to have given a measured water flow response. However, as they require specialized engineering analyses, they are excluded from the scope of these test methods. 1.6 These test methods apply to soils that do not change significantly in volume during changes in volumetric water content or suction, or both (that is, expansive clays or collapsing soils). This implies that these methods should be used for sands, silts, and clays of low plasticity. 1.7 The methods apply only to soils containing two pore fluids: a gas and a liquid. The liquid is usually water and the gas is usually air. Other fluids may also be used if requested. Caution shall be exercised if the liquid being used causes shrinkage or swelling of the soil. 1.8 The units used in reporting shall be SI units in order to be consistent with the literature on water flow analyses in unsaturated soils. The hydraulic conductivity shall be reported in units of [m/s], the matric suction in units of [kPa], the volumetric water content in [m3/m3] or [%], and the degree of saturation in [m3/m3]. 1.9 All observed and calculated values shall conform to the guide for significant digits and rounding established in Practice D6026. The procedures in Practice D6026 that are used to specify how data are collected, recorded, and calculated are regarded as the industry standard. In addition, they are representative of the significant digits that should generally be retained. The procedures do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the objectives of the user. Increasing or reducing the significant digits of reported data to be commensurate with these considerations is common practice. Consideration of the significant digits to be used in analysis methods for engineering design is beyond the scope of these test methods. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. Keywords column test; hydraulic conductivity function; permeameter; soil water retention curve; unsaturated soils; ICS Code ICS Number Code 13.080.40 (Hydrological properties of soil) DOI: 10.1520/D7664-10R18E01 This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|