FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-D8535 2023ASTM D8535-23Active Standard: Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances (PFAS) in Soil/Biosolid Matrices by Solvent Extraction, Filtering, and Followed by Liquid Chromatography Tandem Mass Spectrometry (LC/MS/MS)ASTM D8535Scope 1.1 This test method covers the determination of per- and polyfluoroalkyl substances (PFAS) in soil/biosolid matrices by solvent extraction, filtering, separation using liquid chromatography (LC), and detection with tandem mass spectrometry (MS/MS). These analytes are extracted from soil/biosolids with basic water and methanol then qualitatively and quantitatively determined by this test method. Quantitation is by selected reaction monitoring (SRM), sometimes referred to as multiple reaction monitoring (MRM). 1.2 The reporting limit (RL) and reporting range (see Note 2) for the target analytes are listed in Table 1. The reporting limit is calculated from the concentration of the Level 1 calibration standard as shown in Table 5 for the PFAS after taking into account a 2 g sample weight and a final extract volume of 10 mL, 50 % water/50 % MeOH with 0.1 % acetic acid. The final extract volume is assumed to be 10 mL because 10 mL of 50 % water/50 % MeOH with 0.1 % acetic acid was added to each soil sample and only the liquid layer after extraction is filtered, leaving the solid and any residual solvent behind. Sporadic PFAS hits due to PFAS contamination in consumables/collection tools used during sample collection and preparation is possible while executing this standard and must be monitored. All samples should be taken at a minimum as duplicates in order to compare the precision between the two prepared samples to help ensure the concentration/positive result is reliable. Note 1: This standard only includes the determination of the analytes listed in Table 1 and is only applicable to soil and biosolid matrices; any added compost or soil additives may contain PFAS that may be bound and not able to be determined by this method. Analysis of packaging materials and polymeric PFAS moieties are not amenable to this standard. Note 2: Injection volume variations and sensitivity of the instrument used will change the reporting limit and ranges. 1.2.1 Recognizing continual advancements in the sensitivity of instrumentation, advancements in column chromatography, and other processes not recognized here, the reporting limit may be lowered assuming the minimum performance requirements of this test method at the lower concentrations are met. 1.2.2 Depending on data usage, you may modify this test method but limit to modifications that improve performance while still meeting or exceeding the method quality acceptance criteria. Modifications to the solvents, ratio of solvent to sample, or shortening the chromatographic run simply to save time are not allowed. Use Practice E2935 or similar statistical tests to confirm that modifications produce equivalent results on non-interfering samples. In addition, use Guide E2857 or equivalent statistics to revalidate the modified test. 1.2.3 Analyte detections under the reporting limit are estimated concentrations. If results are to be reported below the RL using this standard and following the method detection limit procedure in 40 CFR Part 136 Appendix B, data shall be qualified estimated and extra caution must be taken to evaluate and identify false positives. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. Keywords biosolids; environmental; EPA; PFAS; pollution; soil; ICS Code ICS Number Code 71.040.50 (Physicochemical methods of analysis) DOI: 10.1520/D8535-23 This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|