FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-D8551 2024ASTM D8551-24aRedline Standard: Standard Practices for Permanent Monitoring Systems for Electrical Leak Detection and LocationASTM D8551Scope 1.1 These practices describe standard procedures for using electrical methods to locate leaks in geomembranes covered with liquid, earthen materials, waste, and/or any material deposited on the geomembrane. 1.2 These practices are intended to ensure that permanent leak detection and location systems are effective, which can result in complete containment (no leaks in the geomembrane). 1.3 Not all sites will be easily amenable to this method, but some preparation can be performed in order to enable this method at nearly any site as outlined in Section 6. If ideal testing conditions cannot be achieved (or designed out), the method can still be performed, but any issues with site conditions must be documented. 1.4 Permanent monitoring systems for electrical leak detection and location can be used on geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, and other containment facilities including civil engineering structures. The procedures are applicable for geomembranes made of materials such as polyethylene, polypropylene, polyvinyl chloride, chlorosulfonated polyethylene, bituminous material, and other sufficiently electrically insulating materials. 1.5 Any permanent electrical monitoring system must detect the occurrence of a leak through the geomembrane, and it must last longer than the monitored geomembrane by nature of the concept. Therefore, all buried components and mechanical and electrical connections must be made of material either the same as the geomembrane, in case of sensors situated above geomembrane, or made from a material with a longer lifespan in cases where they are situated under the monitored geomembrane. 1.6 Permanent electrical monitoring systems are comprised of either large mesh pads separated by nominal spaces, or a grid of sensors situated either below the geomembrane or above the geomembrane or in both positions (below and above the geomembrane). In specific cases, sensors may be situated only at the perimeter of the monitored lined facility. 1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.8 The electrical methods used for geomembrane leak location should be attempted only by qualified and experienced personnel. Appropriate safety measures should be taken to protect the leak location operators, as well as other people at the site. 1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. Keywords construction quality assurance; electrical leak location measurement; geoelectric leak location; geomembrane; leak detection; leak location; permanent monitoring system; ICS Code ICS Number Code 21.140 (Seals, glands) DOI: 10.1520/D8551-24A This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|