FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E2543 2008ASTM E2543 - 08Standard Specification for Portable Air Heaters Used at Personnel Decontamination Stations and SheltersActive Standard ASTM E2543 | Developed by Subcommittee: E54.03 Book of Standards Volume: 15.08 ASTM E2543Abstract This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit ' s ability to perform its function. The preferred fuels for the heater section of the portable air heater are diesel fuel, gasoline, or bottled propane gas. Measurement of the air heater unit ' s air flow and input and output temperatures shall be performed. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. Significance and Use p>The use of these acceptance tests will insure that organizations buying portable heaters will be assured the heaters meet certain performance requirements. 1. Scope 1.1 This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. Note 1These heaters are not intended to be used for the decontamination for any other surface or material. Also, these heaters are intended to be portable and easy to use by first responders during a chemical, biological, radiological, nuclear, and explosive (CBRNE) event. 1.2 This specification contains a specification section and a test methods section so users need to refer to the section applicable to their needs when using this standard specification. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Note 2The U.S. first responder personnel using the equipment manufactured under this standard are not likely to be familiar with SI units so English units need to be included as part of the system documentation and shown on control panels for any equipment sold to U.S. organizations. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 10.1 These test methods shall be used to insure portable air heaters comply with the requirements of this specification.
ASTM Standards D3195 Practice for Rotameter Calibration E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves NFPA Standard NFPA70 National Electrical CodeNIST Standard RecommendedPracticeG Stopwatch and Timer CalibrationsKeywords decontamination; shelter; warm air; ICS Code ICS Number Code 13.200 (Accident and disaster control); 97.100.01 (Domestic, commercial and industrial heating appliances in general) DOI: 10.1520/E2543-08 ASTM International is a member of CrossRef. ASTM E2543The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|