ASTM E481-03
Historical Standard: ASTM E481-03 Standard Test Method for Measuring Neutron Fluence Rate by Radioactivation of Cobalt and Silver
SUPERSEDED (see Active link, below)
ASTM E481
1. Scope
1.1 This test method covers a suitable means of obtaining the thermal neutron fluence rate, or fluence, in well moderated nuclear reactor environments where the use of cadmium, as a thermal neutron shield as described in Method E 262, is undesirable because of potential spectrum perturbations or of temperatures above the melting point of cadmium.
1.2 This test method describes a means of measuring a Westcott neutron fluence rate (Note 1) by activation of cobalt- and silver-foil monitors (See Terminology E 170). The reaction 59 Co( n, ) 60 Co results in a well-defined gamma emitter having a half-life of 1925.5 days (1) . The reaction 109 Ag( n, ) 110m Ag results in a nuclide with a complex decay scheme which is well known and having a half-life of 249.76 days (14) . Both cobalt and silver are available either in very pure form or alloyed with other metals such as aluminum. A reference source of cobalt in aluminum alloy to serve as a neutron fluence rate monitor wire standard is available from the National Institute of Standards and Technology (NIST) as Standard Reference Material 953. The competing activities from neutron activation of other isotopes are eliminated, for the most part, by waiting for the short-lived products to die out before counting. With suitable techniques, thermal neutron fluence rate in the range from 10 9 cm 2 s 1 to 3 10 15 cm 2 s 1 can be measured. For this method to be applicable, the reactor must be well moderated and be well represented by a Maxwellian low-energy distribution and an (1/ E ) epithermal distribution. These conditions are usually met in positions surrounded by hydrogenous moderator without nearby strongly absorbing materials. Otherwise the true spectrum must be calculated to obtain effective activation cross sections over all energies.
Note 0Westcott fluence rate = Equation 1 - v 0 0 n(v)dv.
1.3 The values stated in SI units are to be regarded as the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E170 Terminology Relating to Radiation Measurements and Dosimetry
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
E181 Test Methods for Detector Calibration and Analysis of Radionuclides
E262 Test Method for Determining Thermal Neutron Reaction Rates and Thermal Neutron Fluence Rates by Radioactivation Techniques
Keywords
activation; cobalt; dosimetry; foil; silver; thermal neutron; Cobalt- and silver-foil monitors; Fluence; Neutron activation reactions; Neutron flux/fluence; Radioactivation--fast neutron flux; Silver-foil monitors; Thermal neutron flux ;
ICS Code
ICS Number Code 17.240 (Radiation measurements); 27.120.30 (Fissile materials and nuclear fuel technology)
DOI: 10.1520/E0481-03