ASTM F1216-05
Historical Standard: ASTM F1216-05 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube
SUPERSEDED (see Active link, below)
ASTM F1216
1. Scope
1.1 This practice describes the procedures for the reconstruction of pipelines and conduits (4 to 108-in. diameter) by the installation of a resin-impregnated, flexible tube which is inverted into the existing conduit by use of a hydrostatic head or air pressure. The resin is cured by circulating hot water or introducing controlled steam within the tube. When cured, the finished pipe will be continuous and tight-fitting. This reconstruction process can be used in a variety of gravity and pressure applications such as sanitary sewers, storm sewers, process piping, electrical conduits, and ventilation systems.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 7.4.2.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D543 Practices for Evaluating the Resistance of Plastics to Chemical Reagents
D638 Test Method for Tensile Properties of Plastics
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D903 Test Method for Peel or Stripping Strength of Adhesive Bonds
D1600 Terminology for Abbreviated Terms Relating to Plastics
D3567 Practice for Determining Dimensions of Fiberglass (Glass-Fiber-Reinforced Thermosetting Resin) Pipe and Fittings
D3839 Guide for Underground Installation of Fiberglass (Glass-FiberReinforced Thermosetting-Resin) Pipe
D5813 Specification for Cured-In-Place Thermosetting Resin Sewer Piping Systems
E797 Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method
F412 Terminology Relating to Plastic Piping Systems
AWWA Standard
ManualonCleaningandLNASSCO Standard
RecommendedSpecificaKeywords
Resin-impregnated tube; Resins; Sewer pipe (thermoplastic); Thermosetting plastic pipe/tubing/fittings; Steel pipe; Styrene; Underground installation--water supply/distribution systems; Water supply/distribution systems; Bypassing; Conduit joining system; Conduits; Curing (in pipeline/conduit rehabilitation); Drainage materials/systems; Drain/waste/vent (DWV)--thermoplastics; Epoxy resin pipe fittings; Epoxy resins; Gravity sewer pipe; Inspection; Inversion; Land drainage piping systems; Nonpressure piping; Polybutylene (PB) pipe; Polyethylene (PE) conduit; Polyethylene (PE) pipe; Poly(vinyl chloride)(PVC) conduits; Pressure pipelines/piping systems; Rehabilitation--sewerlines; Reinforced thermosetting-resin pipe (RTRP);
ICS Code
ICS Number Code 23.040.20 (Plastic pipes)