1. Scope
1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits by the installation of a field-fabricated PVC liner. After installation of the liner, cementitious grout is injected into the annular space between the liner and the existing sewer or conduit. The rehabilitation of the host structure by this installation practice results in a rigid composite structure (PVC/grout/existing pipe). This rehabilitation process may be used in a variety of gravity applications, such as sanitary sewers, storm sewers and process piping of man-entry sizes (36 to 144 in. in vertical dimension). The profile strips used for field fabrication of PVC liners are supplied in coils for spiral winding of the liner or in custom-cut flat panels for circumferential lining of all or any portion of the circumference of the host conduit (see Figs.1 and 2).
1.2 The values in parentheses are provided for information purposes only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C942 Test Method for Compressive Strength of Grouts for Preplaced-Aggregate Concrete in the Laboratory
C969 Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
D883 Terminology Relating to Plastics
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1735 Practice for Testing Water Resistance of Coatings Using Water Fog Apparatus
F412 Terminology Relating to Plastic Piping Systems
NASSCO Standard
SpecificationGuideliKeywords
Cement grout; Conduits; Liner; Poly(vinyl chloride)(PVC) pipe; Poly(vinyl chloride)(PVC) profile strip/liner; Profile strip; Rehabilitation--sewerlines; Sewer pipe (thermoplastic); Storm sewer/drainage pipe; Underground installation--water supply/distribution systems;