FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-F1719 2008ASTM F1719 - 96(2008)Standard Specification for Image-Interactive Stereotactic and Localization SystemsActive Standard ASTM F1719 | Developed by Subcommittee: F04.31 Book of Standards Volume: 13.01 ASTM F1719Abstract This specification covers the different types, appropriate applicability, and safety and sterilizability requirements that pertain to the combined use of stereotactic instruments or systems with imaging techniques, to direct a diagnostic or therapeutic modality into a specific target within the brain, based on localization information derived from such imaging techniques. A stereotactic instrument or system is a guiding, aiming, or viewing device used in human neurosurgery for the purpose of manually directing a system or treating modality to a specific point within the brain by radiographic, imaging, or other visualization or identification of landmarks or targets or lesions. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. Significance and Use The following uses of imaging-guided stereotactic surgery have been documented in the literature, and are presented as examples. This list is not inclusive of all the techniques presently being used, and certainly does not reflect nor intend to impede the development of new techniques in the future: Biopsy of intracranial tissue, Implantation of radioisotopes by various techniques, Aspiration of cysts, Aspiration of abcesses, Instillation of therapeutic agents, including antibiotics, chemotherapeutic agents, tissue, drugs, and neurotransmitters, Insertion of electrodes for recording of electrical activity or impedance, Insertion of probes for lesion production in functional neurosurgery, Insertion of electrodes for stimulation, Aspiration of hematomas, Resection of mass lesions, Laser vaporization or removal of intracranial tissue, Guidance of externally delivered radiation therapy, Adjunct to open surgical procedures, Placement of catheters into ventricles, cysts, and so forth, and Hyperthermia. 1. Scope 1.1 This specification covers the combined use of stereotactic instruments or systems with imaging techniques, to direct a diagnostic or therapeutic modality into a specific target within the brain, based on localization information derived from such imaging techniques. 1.2 For the purpose of this specification, a stereotactic instrument or system is a guiding, aiming, or viewing device used in human neurosurgery for the purpose of manually directing a system or treating modality to a specific point within the brain by radiographic, imaging, or other visualization or identification of landmarks or targets or lesions. 1.3 Definition of Stereotactic Imaging Systems Types of imaging-guided systems all require three components: an imaging system, a stereotactic frame, or other physical device to identify the position of a point in space, and a method to relate image-generated coordinates to frame or device coordinates. See Performance Specification F 1266 . The imaging technique must reliably and reproducibly generate data concerning normal or abnormal anatomic structures, or both, that can interface with the coordinate system of the stereotactic frame or other stereotactic system. The imaging-guided systems must allow accurate direction of therapeutic, viewing or diagnostic modalities to a specific point or volume or along a specific trajectory within the brain or often accurate estimation of structure size and location allowing biopsy, resection, vaporization, implantation, aspiration, or other manipulation, or combination thereof. The standards of accuracy, reproducibility, and safety must be met for the imaging modality, the stereotactic system, and the method of interface between the two, and for the system as a whole. The mechanical parts of the imaging modality and the stereotactic system should be constructed to allow maximal interaction with minimal interference with each other, to minimize imaging artifact and distortion, and minimize potential contamination of the surgical field. 1.4 General Types of Imaging that May Be Used With Stereotactic Systems Currently employed imaging modalities used in imaging-guided stereotactic systems include radiography, angiography, computed tomography, magnetic resonance imaging, ultrasound, biplane and multiplane digital subtraction angiography, and positron emission scanning. However, it is recognized that other modalities may be interfaced with currently available and future stereotactic systems and that new imaging modalities may evolve in the future. Standards for imaging devices will be dealt with in documents concerning such devices, and will not be addressed herein. 1.5 General types of diagnostic modalities include biopsy instruments, cannulas, endoscopes, electrodes, or other such instruments. Therapeutic modalities include, but are not limited to, heating, cooling, irradiation, laser, injection, tissue transplantation, mechanical or ultrasonic disruption, and any modality ordinarily used in cerebrospinal surgery. 1.6 Probe Any system or modality directed by stereotactic techniques, including mechanical or other probe, a device that is inserted into the brain or points to a target, and stereotactically directed treatment or diagnostic modality. Note 1Examples presented throughout this specification are listed for clarity only; that does not imply that use should be restricted to the procedures or examples listed. 1.7 Robot A power-driven servo-controlled system for controlling and advancing a probe according to a predetermined targeting program. 1.8 Digitizer A device that is directed to indicate the position of a probe or point in stereotactic or other coordinates. 1.9 Frameless System A system that does not require a stereotactic frame, that identifies and localizes a point or volume in space by means of data registration, and a method to relate that point or volume to its representation derived from an imaging system. 1.10 The values stated in SI units are to be regarded as the standard. 1.11 The following precautionary caveat pertains only to the test method portion, Section 3, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards F1266 Performance Specification for Cerebral Stereotactic Instruments Keywords Sterilization; Therapeutic modality; Anesthesia equipment--specifications; Biplane radiographic techniques; Calibration--medical/surgical devices/applications; Diagnostic modality; Image interactive localization systems; MRI (magnetic resonance imaging); Operating room safety; Positron emission tomography; Stereotactic instruments/systems; ICS Code ICS Number Code 11.040.99 (Other medical equipment) DOI: 10.1520/F1719-96R08 ASTM International is a member of CrossRef. ASTM F1719This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|