ASTM F1871-98e2
Historical Standard: ASTM F1871-98e2 Standard Specification for Folder/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
SUPERSEDED (see Active link, below)
ASTM F1871
1. Scope
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded/formed poly (vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation.
1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is installed into and then expanded to provide a close fit to the wall of the original conduit, forming a new structural pipe-within-a-pipe.
Note 1For installation procedures refer to Practice F 1867.
1.3 This specification includes pipe made only from materials specified in Section . This specification does not include pipe manufactured from reprocessed, recycled, or reclaimed PVC.
1.4 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only.
1.5 The following precautionary statement pertains only to the test method portion, Section 11, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.6 There is no similar or equivalent ISO Standard.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D618 Practice for Conditioning Plastics for Testing
D638 Test Method for Tensile Properties of Plastics
D648 Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight)
F412 Terminology Relating to Plastic Piping Systems
F1057 Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique
F1867 Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation
Federal Standard
Fed.Std.No.123 Marking for Shipment (Civil Agencies)Military Standard
MIL-STD-129 Marking for Shipment and StorageKeywords
installation, underground; plastic pipe, thermoplastic; poly (vinyl chloride) (PVC) plastic pipe; rehabilitation, trenchless technology;Poly(vinyl chloride)(PVC) pipe--specifications; Folded PVC pipe; Rehabilitation--sewerlines; Sewer pipe (thermoplastic)--specifications; Underground installation--water supply/distribution systems; Conduits--specifications;
ICS Code
ICS Number Code 23.040.20 (Plastic pipes); 83.080.20 (Thermoplastic materials)
DOI: 10.1520/F1871-98E02
ASTM International is a member of CrossRef.