ASTM F1915-05
Historical Standard: ASTM F1915-05 Standard Test Methods for Glazing for Detention Facilities
SUPERSEDED (see Active link, below)
ASTM F1915
1. Scope
1.1 These test methods, including a fire test response method, cover the apparatus, procedures, and acceptance conditions for evaluating the normal operational performance and the performance characteristics under assault conditions of detention glazing used in window and door assemblies in detention and correctional facilities; thus, these test methods only give an indication of the performance characteristics of detention glazing in actual service. Such variables as installation and maintenance conditions are not considered except as otherwise included in this test method.
1.2 It is the intent of these test methods to help ensure that detention glazing performs at or above minimum acceptable levels to restrict inmate passage to unauthorized areas, to confine inmates, to delay and frustrate escape attempts and to resist vandalism.
1.3 Tools defined in these test methods are representative of similar tools or materials, which may become available to inmates within the secure perimeter of detention and correctional facilities, and which could be used to inflict similar product damage.
1.4 These test methods should not be used to establish or confirm the absolute prevention of forced entries or exits. These test methods define five factors (tool, temperature, techniques, time, and number of impacts) used to determine resistance to defined attacks.
1.5 The values stated in inch-pound units are to be regarded as the standard. The SI values in stated parentheses are for information only.
1.6 In these test methods, the specimens are subjected to one or more specific sets of laboratory test conditions. If different test conditions are substituted or the end-use conditions are changed, it is not always possible by or from these test methods to predict changes in the physical attack, or fire-test-response characteristics measured, or both; therefore, the results are valid only for the physical attack, or fire-test-exposure conditions, or both, described in these test methods.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
F1233 Test Method for Security Glazing Materials And Systems
F1450 Test Methods for Hollow Metal Swinging Door Assemblies for Detention and Correctional Facilities
F1577 Test Methods for Detention Locks for Swinging Doors
F1592 Test Methods for Detention Hollow Metal Vision Systems
F1643 Test Methods for Detention Sliding Door Locking Device Assembly
F1758 Test Methods for Detention Hinges Used on Detention-Grade Swinging Doors
UL Standard
UL752 Bullet Resisting EquipmentNIJ Standard
NIJ0108.1 Ballistic Resistant Protective MaterialsKeywords
attack weapons; battering ram; correctional facility; detention facility; fire; flame exposure; glazing; impact test; impactor (blunt and sharp); physical attack; polycarbonate; security glass; security glazing; security grades; temperature (cold and warm); test assembly; test criteria; time (element of); torch;
ICS Code
ICS Number Code 91.060.50 (Doors and windows)
DOI: 10.1520/F1915-05