FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Content DescriptionThis standard presents essential procedures for the disinfection of new and repaired potable water mains. Topics covered include forms of chlorine disinfection, a description of the disinfection procedure, preventive and corrective measures during construction, methods of chlorination, final flushing, bacteriological testing, redisinfection, final connections to existing mains, disinfection procedures when cutting into or repairing existing mains, and special procedures for caulked tapping sleeves. Appendixes cover chlorine residual testing, chlorine dosages, and disposal of heavily chlorinated water. Major revisions made to the standard in this edition include the following: Expanded guidance for disinfecting existing water mains after repair. This includes a rationale for evaluating risk during pipe repairs, and the level of disinfection and sampling needed under each of those conditions. The revision also clarifies differences in the requirements between new and repaired mains. Added a spray disinfection method for large transmission mains. Changed the requirement for bacteriological sampling in new mains from two sets of samples 24 hours apart to add two options for two sets of samples: Option A samples are 16 hours apart and Option B samples are 15 minutes apart after a 16 hour rest period. The flushing rate of 2.5 ft/sec has been increased to 3.0 ft/sec for a scour flush based on testing performed under recent studies. References to new standard ANSI/AWWA C655 are included for dechlorination and disposing of heavily chlorinated water. The update takes into account the findings from a recent project from the Water Research Foundation (Project No. 4307, Effective Microbial Control Strategies for Main Breaks and Depressurization).The following editions for this book are also available...
This book also exists in the following packages...Subscription InformationMADCAD.com AWWA Standards & Manuals subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).
Some features of MADCAD.com AWWA Standards & Manuals Subscriptions are:
- Floating concurrency model: Set your concurrency level and share your AWWA Standards & Manuals Subscriptions among your offices enterprise-wide.
- Immediate Access: As soon as the transaction is completed, your AWWA Standards & Manuals Subscription will be ready for access.
For any further information on MADCAD.com AWWA Standards & Manuals Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About AWWAEstablished in 1881, the American Water Works Association is the oldest and largest nonprofit, scientific and educational organization dedicated to safe and sustainable water in the world. With more than 50,000 members worldwide and 43 Sections in North America, AWWA advances public health, safety and welfare by uniting the efforts of the entire water community. AWWA Offers education to water professionals Advocates for safe and sustainable water Collects and share knowledge Creates volunteering opportunities |
GROUPS
|