FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of 21/30431504 DC 2021This document is applicable to space heaters, inset appliances and cookers fired by wood pellets, mechanically fed up to 50 kW nominal heat output. These appliances typically use auxiliary energy which is measured in this document as well. For inset pellet appliances and especially their testing, additional information from prEN 16510‑2‑2:2021 is relevant. For pellet cookers and especially their testing, additional information from prEN 16510‑2‑3:2021 is relevant. Non-mechanically fed appliances burning solid mineral fuels, peat briquettes and natural or manufactured wood logs are not included in this document, but are covered by prEN 16510‑2‑1:2021 to prEN 16510‑2‑5:2021. NOTE 1 These appliances could have an integral fuel hopper or be combined with an external fuel hopper. This document is used in conjunction with prEN 16510‑1:2021. The appliances covered by this document provide heat into the space where they are installed. They can be operated with either natural draught or fan-assisted combustion air. Where fitted with a boiler, they can also provide domestic hot water and/or central heating. These appliances burn wood pellets only, in accordance with the appliance manufacturer's instructions. They only operate with the firedoors closed. NOTE 2 A fan-assisted appliance does still operate under negative pressure in the flue gas system. This document specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emissions), instructions and marking together with associated test methods and test fuels. This document is not applicable to appliances:
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|