FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of 21/30431522 DC 2021This document specifies calculations for the dimensioning of Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) based upon the required nominal heat output of the stove as declared by the producer. The Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) are of individual one-off construction design. The document can be used for log wood fired Kachelöfen (tiled stoves) that burn one fuel load per storage period with a maximum load between 10 kg and 40 kg (log wood with water content from 12 % to 20 %, thickness of 5 cm to 10 cm in diameter, length varies usually from 25 cm to 50 cm, and is oriented toward the combustion chamber dimensions) and a storage period (nominal heating time) between 8 h and 24 h. This document is valid for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) equipped with fireclay as interior material, with an apparent density between 1,750 kg/m3 and 2,300 kg/m3, a degree of porosity from 17 % up to 33 % by volume and a heat conductivity from 0,90 W/mK up to 1,30 W/mK (temperature range 20 °C to 400 °C). This document is valid for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) with combustion air supply from the side via a heating door frame or the standing grate of the heating door into the combustion chamber. The document is valid for an inflow speed of the combustion air between 2 m/s and 4 m/s. This document also applies to the combination with combustion chambers that are suitable for one-off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) and for which compliance with the legally required emission values has been verified as part of a type test by an accredited and/or notified body. This document is applicable to combustion chambers:
With regard to the type test, this document is applicable combustion chambers which are:
This document applies to type tested combustion chambers designed for batch fired pellet burning if meeting the requirements according to this document (air-fuel ratio between 1.95 and 3,95, the load of the pellets shall be burned in 78 ± 20 min). This document is not valid for combinations with water heat exchangers for central heating or other heat absorbing elements like open water tanks and glass plates greater than 1/5 of the combustion chamber surface, etc. This document is not valid for mass-produced prefabricated stoves (slow heat release appliances) or partly prefabricated stoves (slow heat release appliances) according to EN 15250 .
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|