BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of 25/30462473 DC 2025This document describes the test and assessment procedure for determining the contribution of reactive fire protection systems to the fire resistance of solid steel bars used as tension members, when exposed to the standard temperature/time curve specified in EN 1363-1. In special circumstances, where specified in National Building Regulations, there can be a need to subject reactive fire protection systems to a slow heating curve (smouldering fire) as defined in EN 1363-2. The corresponding test and assessment procedure are described in Annex E. The fire protection performance is determined by testing mechanically loaded steel bars in horizontal orientation. Information regarding the testing of additional unloaded specimens is given to assess the influence of the bar orientation and smouldering fire behaviour. The principles of the testing and assessment procedure can also be applied for other section shapes such as angles, channels and flats. This document does not include steel bars used as reinforcement in concrete construction. The document is applicable to steel bars up to a maximum diameter of 130 mm. In the case of rectangular bars, the maximum edge length shall be limited to 130 mm with a maximum aspect ratio of 2:1 against the shorter edge length. The test programme and the assessment are designed to cover: - a range of valid fire protection classification periods; - a range of thickness of the applied reactive fire protection system; - a range of steel bar dimensions and profiles; - a range of specified design temperatures; - a range of load utilisation factors in case of fire; - a range of bar orientation. This document also provides the assessment procedure, which prescribes how the analysis of the test data shall be made and gives guidance on the procedures by which interpolation shall be undertaken. The assessment procedure is used to establish: a) on the basis of data derived from mechanically loaded testing steel bar, any practical constraints on the use of the reactive fire protection system under fire test conditions (the physical performance); b) on the basis of the temperature data derived from testing steel bar the thermal properties of the reactive fire protection system (the thermal performance). The limits of applicability of the results of the assessment arising from the fire test are defined together with permitted direct application of the results to different steel types and sizes over the range of thicknesses of the applied reactive fire protection system tested.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|