Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(20)
(19)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1621)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS 4485-4:1996 Water cooling towers - Code of practice for structural design and construction
    Edition: 1996
    $418.55
    / user per year

Description of BS 4485-4:1996 1996

This Part of BS 4485 gives recommendations for the structural design and construction of water cooling towers of the following types:

  1. type 1. Natural draught or assisted draught towers, in which the total air flow is wholly or partly induced by a reinforced concrete shell of hyperboloidal form;

  2. type 2. Mechanical draught towers, in which the total air flow is induced wholly by mechanical means within an enclosed structure.

It applies only to those cooling towers constructed or erected on site and excludes factory assembled towers. In addition, matters relating to construction and workmanship in concrete and other materials are dealt with only in so far as they are specific to cooling tower construction. Other items of construction are referred to in appropriate specifications.

This code of practice covers the design of towers up to 170 m in height. However certain restrictions apply to formulae used for towers greater than 120 m in height.

NOTE For cooling towers of type 1, shells similar in shape to the true hyperboloidal form may be considered. Where these other shapes are adopted then certain sections of this standard may not be strictly applicable.



Applicable to structural design and construction on site of hyperboloidal shell natural draught towers, and to mechanical draught towers.