Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(21)
(20)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1635)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS 8103-3:2009 Structural design of low-rise buildings - Code of practice for timber floors and roofs for housing
    Edition: 2009
    $538.63
    / user per year

Description of BS 8103-3:2009 2009

This Part of BS 8103 gives recommendations for the sizes of timber elements, fixings, and their connections with masonry walls, etc. It applies to detached, semi-detached, terraced houses and flats (with not more than four self-contained dwelling units per floor, accessible from one staircase) of not more than three storeys above ground, intended for domestic occupation. The recommendations also apply to single-storey non-residential buildings, e.g. domestic garages and annexes, not exceeding 36 m2 in floor area.

The design of proprietary housing systems, i.e. cross wall constructions, timber framed houses, steel or concrete framed constructions, concrete panel constructions, is not covered by this standard.

The recommendations of this Part of BS 8103 are applicable only to housing where:

  1. the construction comprises masonry walls, timber roofs, suspended timber or precast concrete intermediate floors, suspended timber or concrete ground floors (either suspended or ground bearing);

  2. the roof profile is symmetrical duopitch, monopitch or flat;

    NOTE 1 Pitched roofs of trussed rafter or traditional constructions are covered, but not constructions using principal trusses. Hip ends and “L” shaped plans are not specifically covered although values are given for jack rafters.

  3. the maximum clear span of a pitched roof does not exceed 12.0 m and imposes a total load on the supporting perimeter walls not greater than 12 kN/m run;

  4. gable and separating walls are of masonry construction extending up to the roof line in the case of pitched roofs;

  5. the roof area is not larger than 200 m2 on plan; or, in the case of pitched roofs where no parapets exist, one of the roof dimensions does not exceed 10 m;

  6. there are no other buildings within 1.5 m of the perimeter of the building;

  7. the roof has no abrupt changes of height greater than 1m on which snow drifting could occur;

    NOTE 2 This limitation does not apply to the change of height between the main roof and the roof of a lower annexe, if the roof area of the annexe does not exceed 36 m2. Chimneys and dormers whose vertical elevation areas, against which a drift could form, are less than 1 m2, need not be considered as being an abrupt change of height.

  8. the maximum clear span of any floor joist or flat roof joist does not exceed 6.0 m;

  9. the design wind criteria is within the scope of BS 8103;

    NOTE 3 Guidance is given in BS 8103‑1 and BS 8103‑2 on how to determine whether the design wind criteria for a building on a particular site is within the scope and application of BS 8103. Guidance is given in Annex M regarding the determination of snow load for a particular site.

  10. no part of any wall or roof is higher than 15m above the lowest adjacent ground level;

  11. floor joists, ceiling joists, flat roof joists, common or jack rafters or trussed rafters are spaced at centres which do not exceed 600 mm;

  12. the stability requirements and dimensional limitations accord with BS 8103‑1:1995+A1:1995, Clause 5.

The sizes of timber shown in the span tables are limited to those normally readily available but do not preclude the use of larger or different sizes if justified by specialist calculation.

The design requirements and those for durability and timber preservation given in this Part of BS 8103 are related only to structural considerations.

For trussed rafter roofs, this standard contains only as much information as is necessary and mainly comprises references to BS 5268‑3 2).



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X