FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN 1359:2017 2017This European Standard specifies the requirements and tests for the construction, performance, safety and production of class 1,5 diaphragm gas meters (referred to as meters). This applies to meters with co-axial single pipe, or two pipe connections, that are used to measure volumes of fuel gases, which are within the limits of test gases of the 1st, 2nd and 3rd families described in EN 437. The meters have maximum working pressures not exceeding 0,5 bar and maximum actual flow rates not exceeding 160 m3.h?1 over a minimum ambient temperature range of ?10 °C to 40 °C and a gas temperature range as specified by the manufacturer with a minimum range of 40 K. This standard applies to meters with and without built-in temperature conversion that are installed in locations with vibration and shocks of low significance (see MID Annex 1 Chapter 1.3.2 (a), class M1). It also applies to meters in: - closed locations (indoor or outdoor with protection as specified by the manufacturer) both with condensing humidity or with non-condensing humidity; or, if specified by the manufacturer: - open locations (outdoor without any covering) both with condensing humidity and with non-condensing humidity; - in locations with electromagnetic disturbances corresponding to those likely to be found in residential, commercial and light industrial buildings (see MID Annex 1 Chapter 1.3.3 (a), class E1). Unless otherwise stated, all pressures given in this document are gauge pressure. Requirements for electronic indexes, batteries, valves incorporated in the meter and other additional functionalities are given in EN 16314. Unless otherwise stated in a particular test, the tests are carried out on meters that include additional functionality devices intended by the manufacturer. Clauses 1 to 9 and Annexes B and C are for design and type testing only. NOTE The content of OIML Publication 'International Recommendation R 137' has been taken into account in the drafting of this standard. If no specific requirements are given for test equipment, the instruments used should be traceable to a national or international reference standard and the uncertainty (2?) should be better than 1/5 of the maximum value of the parameter to be tested. For differential results the repeatability (2?)/resolution should be better than 1/5 of the maximum value of the parameter to be tested.
The following editions for this book are also available...
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|