FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN 15510:2017 - TC 2020This European Standard specifies the inductively coupled plasma atomic emission spectroscopy (ICP-AES) method for the determination of the elements calcium, sodium, phosphorus, magnesium, potassium, iron, zinc, copper, manganese, cobalt, molybdenum and lead. The elements calcium, sodium, phosphorus, magnesium, potassium, iron, zinc, copper, manganese, cobalt, molybdenum and lead are extracted either in feeds mainly consisting of organic matter after dry ashing and dissolving in hydrochloric acid or in feeds mainly consisting of inorganic matter after wet digestion with hydrochloric acid. For the determination of extractable lead in minerals and feeds containing phyllosilicates (e.g. kaolinite clay) wet digestion with nitric acid should be used. The method was successfully tested for: - calcium, sodium, phosphorus, magnesium, potassium, iron, zinc, copper, manganese, cobalt and molybdenum in the following animal feeding stuffs: 2 complete feeds (pig feed, sheep feed), 1 feed material (phosphate), 1 mineral premixture and 2 complementary feeds (2 mineral feeds), - lead in 2 feed materials (phosphate, CaCO3), 2 feed additives (Bentonite, CuSO4), 1 complementary feed (mineral feed) The method detection limit for each element is dependent on the sample matrix and the instrument. The method is not applicable for the determination of a low concentration of elements. The limit of quantification should be 3 mg/kg or lower. This method also applies for the determination in products with high element content (>5 %). For this purpose the accuracy of the method has to be checked individually. NOTE 1 EN 15621 uses the pressure digestion mode, therefore lower results may be obtained with the described method in this standard.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|