FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN 16215:2020 2020This document is applicable to the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), (together termed ‘dioxins’ (PCDD/Fs)) and dioxin-like PCBs and non-dioxin-like PCBs (dl-PCBs and ndl-PCBs) in animal feeding stuffs. Collaborative studies have been carried out. The method is suitable for the determination of dioxins, dl-PCBs and ndl-PCBs at the appropriate MRL in compound feed and ingredients e.g. oil, mineral clay. The method is applicable to samples containing trace level amounts of one or more dioxins, dioxin-like PCBs and non-dioxin-likePCBs. The limit of quantification (LOQ) is
For determination of dioxins and dioxin-like PCBs, the procedure can be used as confirmatory method as defined by Commission Regulation (EC) No 152/2009 for dioxins and dl-PCB in feed [1]. Confirmatory methods as described in this standard are high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) methods. If only the analysis of non-dioxin-like PCBs is required, a GC-LRMS method can be used (e.g. EN 15741 [2]) provided that appropriate analytical performance criteria are met in the relevant range for the matrix of interest. This document is split into four modules. Each module describes a part of the whole procedure (see Figure 1 and Figure 2) to be followed:
Each module describes a part of the whole method as well as, when applicable, alternatives which should be equivalent. Each module has to be regarded as an example. Combining modules and/or alternatives gives a highly flexible, “performance based” procedure. It is permitted to modify the method if all performance criteria laid down in Commission Regulation (EC) No 152/2009 [1] are met. Any deviation of the described method, combination of modules needs to be recorded as part of the QA/QC procedures of accredited laboratories and should be available on request.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|