Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94394)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS EN 50341-2-20:2018 - TC Tracked Changes. Overhead electrical lines exceeding AC 1 kV - National Normative Aspects (NNA) for ESTONIA (based on EN 50341-1:2012)
    Edition: 2020
    $736.46
    / user per year

Description of BS EN 50341-2-20:2018 - TC 2020

General (snc) EE.1 Application to new lines In Estonia the standard EN 50341-1 (Part 1) can only be applied using this NNA (EN 50341-2-20) containing National Normative Aspects for Estonia. This Part 2-20 applies to all new overhead electric lines with nominal system voltages exceeding AC 1 kV and also for low voltage (below 1 kV AC) overhead lines performed by aerial cables. The requirements of the structural design are applicable also for DC overhead lines, where the electrical requirements are given in the Project Specification. (ncpt) EE.2 “ New overhead line” A “new overhead line” means a completely new line between two points, A and B. A new branch line of the existing power line should be considered as a new power line including the junction support. Specific requirements for junction support should be defined with the Project Specification. 1.2 Field of application (ncpt) EE.1 Application to covered conductors and aerial cables The standard includes requirements for the design and construction of overhead lines with nominal system voltages up to 45 kV AC equipped with covered conductors and aerial cables. Additionally, the requirements of the equipment standards and manufacturers’ instructions shall be followed. (A-dev) EE.2 Application to mounting of telecommunication equipment The Standard EVS-EN 50341:2013 is applicable to fixing of structural elements for tele-communication (antennas, All Dielectric Self Supporting (ADSS) equipment, junction boxes, etc.), if mounted on power line supports (towers), especially regarding wind forces and ice loads on such fixed elements. The design and installation should be done under the due control of the line owner and/or the competent authority. Mounting of telecommunication equipment on power line supports must be coordinated with the line owner and stated in the Project Specification. This standard applies to telecommunication lines only in the case of their common installation with power lines. This standard does not apply to separately installed telecommunication overhead lines. If telecommunication equipment (antennas, dishes, etc.) will be installed in the transmission line supports, and their size, location or mounting may have major effects on the loads or design of the structures, the requirements of EVS-EN 1993-3-1/NA:2009 shall also to be taken into account. If such structures include conductive parts, the requirements on clearances in subclause 5.8 should be applied. (ncpt) EE.3 Application to installation of other equipment Only equipment belonging to the line (electric or telecommunication line) can be installed on the overhead lines. However, with the permission of the owner of the line, equipment serving communal services or environmental protection like road signs, warning signs or warning balls, etc., may also be installed. The installation height of equipment meant to be installed and maintained by an instructed person shall be such that the work can be done without climbing the support and the distances of safe electrical work can be followed. The additional loads due to this equipment on the line supports shall be taken into account if necessary.

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X