FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN IEC 61869-10:2018 2018This part of IEC 61869 is a product standard and covers only additional requirements for low-power passive current transformers. The product standard for low-power passive current transformers comprises IEC 61869‑1 , together with IEC 61869‑6 and this document with specific requirements. This document is applicable to newly manufactured low-power passive current transformers with analogue output for use with electrical measuring instruments or electrical protective devices having a rated frequency from 15 Hz to 100 Hz. This document covers low-power passive current transformers used for measurement or protection and multi-purpose low-power passive current transformers used for both measurement and protection. Subclause 5.6.1001 covers the accuracy requirements that are necessary for low-power passive current transformers for use with electrical measuring instruments. Subclause 5.6.1002 covers the accuracy requirements that are necessary for low-power passive current transformers for use with electrical protective relays, and particularly for forms of protection in which the prime requirement is to maintain the accuracy up to several times the rated current. If required, the transient accuracy of low-power passive current transformers during fault is also given in 5.6.1002. Low-power passive current transformers have analogue voltage output only (for digital output or for technology using any kind of active electronic components refer to IEC 61869‑8 2 ). Such low-power passive current transformers can include the secondary signal cable (transmitting cable). The principle of operation of derivative low-power passive current transformers using air-core coils (Rogowski coils) is given in Annex 10B and the principle of operation of proportional low-power passive current transformers using iron-core coils with integrated shunt is given in Annex 10C.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|