Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(338)
(589)
(599)
(55)
(234)
(1006)
(690)
(2183)
(117)
(95207)
(63)
(575)
(124)
(33)
(21)
(20)
(95391)
(3)
(17)
(1)
(374)
(322)
(6938)
(241)
(21)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS EN ISO 7396-1:2016+A1:2019 Medical gas pipeline systems - Pipeline systems for compressed medical gases and vacuum
    Edition: 2019
    $569.57
    / user per year

Description of BS EN ISO 7396-1:2016+A1:2019 2019

This part of ISO 7396 specifies requirements for design, installation, function, performance, testing, commissioning and documentation of pipeline systems used in healthcare facilities for the following:

  • oxygen;

  • nitrous oxide;

  • medical air;

  • carbon dioxide;

  • oxygen/nitrous oxide mixtures (see Note 1);

  • helium/oxygen mixtures;

  • (*) oxygen 93;

  • gases and gas mixtures classified as medical device, gases delivered to medical devices or intended for medical purposes or gases and gas mixtures for medicinal use not specified above;

  • air for driving surgical tools;

  • nitrogen for driving surgical tools;

  • vacuum.

NOTE 1 Regional or national regulations may prohibit the distribution of oxygen/nitrous oxide mixtures in medical gas pipeline systems.

NOTE 2 Anaesthetic gas scavenging disposal systems are covered in ISO 7396‑2.

This part of ISO 7396 includes requirements for supply systems, pipeline distribution systems, control systems, monitoring and alarm systems and non-interchangeability between components of different gas/vacuum systems.

This part of ISO 7396 specifies safety requirements for pipeline systems used in healthcare facilities, both public and private. It applies to all facilities providing healthcare services regardless of type, size, location or range of services, including, but not limited to:

  1. acute care healthcare facilities;

  2. internal patient continuing care healthcare facilities;

  3. long-term care facilities;

  4. community-based providers;

  5. ambulatory and external patient care clinics (e.g. day surgery, endoscopy clinics and doctors’ offices).

NOTE 3 This part of ISO 7396 may also be used as reference for pipeline systems for medical gases and vacuum intended to be installed in places other than healthcare facilities.

This part of ISO 7396 applies to the following different types of oxygen supply systems:

  • supply systems in which all sources of supply deliver oxygen; in this case the concentration of the oxygen will be greater than 99%;

  • supply systems in which all sources of supply deliver oxygen 93; in this case the concentration of the oxygen may vary between 90% and 96%;

NOTE 4 A mixture of oxygen 93 and oxygen may be delivered by a medical gas supply system. In this case the concentration of the gas can vary between 90% and >99%.

This part of ISO 7396 also applies to:

  • extensions of existing pipeline distribution systems;

  • modifications of existing pipeline distribution systems;

  • modifications or replacement of supply systems or sources of supply.

Oxygen concentrators for domiciliary use are excluded from the scope of this part of ISO 7396.

NOTE 5 Requirements for oxygen concentrators for domiciliary use are specified in ISO 80601‑2‑69.

(*)EN 14931defines additional requirements for hyperbaric application, in particular for flows and pressures of compressed air required to pressurize the hyperbaric chamber and to drive other connected services. Also included are requirements for oxygen and other treatment gases administered to patients.

This part of ISO 7396 does not apply to vacuum systems intended to be used in dentistry.

This part of ISO 7396 does not apply to filling systems for transportable cylinders and transportable cylinder bundle systems.